(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

XY-Axis Manual Stages, Linear Ball Guide, Thin Type

XY-Axis Manual Stages, Linear Ball Guide, Thin Type

Click this image to zoom it.

Move the mouse over the image to zoom

  • XY-Axis Manual Stages, Linear Ball Guide, Thin Type
  • XY-Axis Manual Stages, Linear Ball Guide, Thin Type

Dimensional Drawing of Manual XY-Axis Stages

Dimensional Drawing
*A40, A60, A80, A100 are available sizes of the screw hole on sliding table
 

Specification Table of Manual XY-Axis Stages

■Specification Table of Manual XY-Axis Stages
Part NumberPositioning Stage Face (mm)Movement (mm)Load Capacity (N)Straightness
(μm)
Minimum Reading
(μm)
Weight (kg)
TypeNo.Horizontal
E-XYSSG4040×40±6.588Within 10100.34
6060×601860.64
8080×80±12.51961.32
100100×1002452

■Alteration of Manual XY-Axis Stages
AlterationsChanging the position of the micrometer knob 
Spec.Center
MISUMI Economy series Manual Positioning Stages Alteration Micrometer Knob Center Type
Side Left and Right Reverse
MISUMI Economy series Manual Positioning Stages Alteration Micrometer Knob Side Up Type
Without Micrometer Rotation
MISUMI Economy series Manual Positioning Stages Alteration Micrometer Knob Side Down Type
CodeACRMN

Specification Overview of Manual XY-Axis Stages


■The movement amount of Manual XY-Axis Stages
  drawing size is when the stroke is 0 mm, and the distance moved left and right based on this is the movement amount.

■Load capacity of Manual XY-Axis Stages
  If it is used in excess of the rated load, the slide table may not move smoothly or may become stuck. Refer to the load capacity when installed horizontally and the "vertical" value when installed vertically,respectively. 
  Linear motion Please note that the accuracy may be lower than the values ​​indicated in the product catalog if the slide table is installed vertically or upside down.

■Straightness This
   refers to the maximum offset to the ideal movement axis (the straight line connecting the start and end points, the red line in the figure below. The black line is the actual motion trajectory) when driving the slide table.Moves the full stroke. 
   Detection method: Place a dial indicator on the slide table, place the pointer on the reference block, move the slide table the full stroke, and then measure the maximum displacement, i.e., straightness.



Economy XY-axis manual stage linear ball type micrometer head thin typeEconomy XY-axis manual stage linear ball type micrometer head thin type

Product Features of Manual XY-Axis Stages

The price is low due to the simplified structure and improved processing technology.

How to use of Manual XY-Axis Stages

■How to install the X-axis sliding table
  When installing the sliding table on the base, the method of moving the sliding table is basically adopted.  See the image below.
  
Economy XY-axis manual stage linear ball type micrometer head thin type
 
DescriptionEconomy XY-axis manual stage linear ball type micrometer head thin installation direction explanation basicEconomy XY-axis manual stage linear ball type micrometer head thin installation direction description ceiling mount Economy XY-axis manual stage linear ball type micrometer head thin installation direction explanation diagram side mounting Economy XY-axis manual stage linear ball type micrometer head thin installation direction description vertical mounting
Installation DirectionbasicCeiling MountSide mountVertical mounting
Load resistance characteristics
Manual XY-Axis StagesChoose from horizontal, inverted, side horizontal or vertical side installation.  Caution is required for other installations.
Manual XY-Axis StagesLoad resistance and accuracy vary greatly depending on the mounting posture.
Manual XY-Axis Stages○: Same level of load resistance.
Manual XY-Axis Stages△: Approximately 1/3 of the horizontal load resistance is a rough guideline, and the vertical load resistance listed in the product catalog is recommended.




■Using the X-axis slide table vertically
  When using the X-axis slide table vertically, be careful with the travel direction not in the same direction as gravity.
  When using the micrometer handle type slide, the slide is returned by the tension spring.  If a force exceeding the spring load is applied, the slide table may fall.
 
Incorrect usageCorrect usage
  
Economy XY-axis manual stage linear ball type micrometer head thin typeEconomy XY-axis manual stage linear ball type micrometer head thin type
Manual XY-Axis StagesDo not apply a load exceeding the vertical load range. 

Caution of Manual XY-Axis Stages

■Stage usage environment of Manual XY-Axis Stages
  Usage environment: 10~50℃, 20~70%RH (non-condensing)
  Recommended usage environment: 22±5℃, 20~70%RH (non-condensing)
■Guide mechanism of Manual XY-Axis Stages
Since a cross roller guide is used as the guide mechanism, inject lubricant in a timely manner according to the usage conditions to prevent the life of the cross roller guide from being reduced and deteriorated due to lubricantreduction.
■Clamping mechanism of Manual XY-Axis Stages
①The clamping mechanism of the slide table is fixed by the frictional force generated by the fastening screw, so if the external force exceeds the frictional force of the clamping mechanism, the slide table will move. The user must takeappropriate measures during use to prevent the table surface from moving. 
②Holding force refers to the value of the force that prevents the slide table from moving in the clamped state. The maximum holding force varies depending on the tightening torque, so ensure sufficient safety factors when designing.
■A slide table with a micrometer knob mounted on the transport mechanism is generally called a standard type if it has a shape like the figure below. You can freely select by combining the installation space, installation posture, andoperation method. However, there are some models where the installation position of the micrometer knob cannot be changed due to the product structure.
■There may be cases where the upper and lower tables are deformed due to differences in the flatness of the installation surface. Deformation of the table surface causes backlash, loosening due to failure to obtain the specifiedpreload, and poor sliding due to excessive preload. Therefore, it is recommended to maintain the flatness of the installation surface at approximately 5 microns.  

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
E-XYSSG40
E-XYSSG40-A
E-XYSSG40-CR
E-XYSSG40-MN
E-XYSSG60
E-XYSSG60-A
E-XYSSG60-CR
E-XYSSG60-MN
E-XYSSG80
E-XYSSG80-A
E-XYSSG80-CR
E-XYSSG80-MN
E-XYSSG100
E-XYSSG100-A
E-XYSSG100-CR
E-XYSSG100-MN
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTable Dimensions Alteration

MYR 1,215.48

1 Piece(s)Available 10 Day(s) 40Standard Type

MYR 1,215.48

1 Piece(s)Available 15 Day(s) 40A

MYR 1,215.48

1 Piece(s)Available 15 Day(s) 40CR

MYR 1,112.06

1 Piece(s)Available 15 Day(s) 40MN

MYR 1,269.68

1 Piece(s)Available 10 Day(s) 60Standard Type

MYR 1,269.68

1 Piece(s)Available 15 Day(s) 60A

MYR 1,269.68

1 Piece(s)Available 15 Day(s) 60CR

MYR 1,166.26

1 Piece(s)Available 15 Day(s) 60MN

MYR 1,615.84

1 Piece(s)Available 15 Day(s) 80Standard Type

MYR 1,615.84

1 Piece(s)Available 15 Day(s) 80A

MYR 1,615.84

1 Piece(s)Available 15 Day(s) 80CR

MYR 1,512.48

1 Piece(s)Available 15 Day(s) 80MN

MYR 1,725.90

1 Piece(s)Available 1 Day(s) 100Standard Type

MYR 1,725.90

1 Piece(s)Available 15 Day(s) 100A

MYR 1,725.90

1 Piece(s)Available 15 Day(s) 100CR

MYR 1,622.54

1 Piece(s)Available 15 Day(s) 100MN

Loading...

  1. 1
Product Overview
MISUMI E-XYSSG series linear ball guide type positioning stages are economy series thin type positioning stages, which can be used in compact spaces. It is mainly used as a positioning stage for simple position adjustment. The body is made of D2 tool steel to achieve high rigidity; the surface is chemically nickel plated to provide a certain degree of rust resistance. Linear ball guide is used for guiding purpose, which meets the requirements of usage accuracy. Prices have been significantly reduced due to local production in China and improved machining process.
Product Features
Feature 1: Production cycle is shortened, shipped within 5 days at the earliest
Feature 2: Low price is achieved by simplifying the structure and improving the machining process.
Feature 3: A wide range of alterations are available to enable installation and operation under different conditions.
Feature 4: By improving the clamping mechanism, the holding force of the positioning stage is greater than that of the standard type clamping mechanism.
Specifications Overview
Type Material Surface TreatmentMovement (mm)Load Capacity (N)Straightness
E-XYSSGD2 Tool SteelChemically Nickel Plating±6.5~±12.588~245Within 10 μm

■Amount of travel
  The catalog drawing size is the state of travel 0mm, and taking this as reference, the distance moved in the left and right directions is the amount of travel.

■Load capacity
 is the force in N that the positioning stage can withstand when the center of gravity of the workpiece is in the center of the positioning stage. If used in excess of the load capacity, the positioning stage may not move properly or get stuck. Refer to the values of "Horizontal" and "Vertical" for the load resistance for horizontal and vertical installation respectively. Note that when the linear motion positioning stage is installed vertically or upside down, the accuracy may be less than the value indicated in the catalog.

■Straightness
  The maximum offset relative to the ideal axis of movement (the line connecting the start and end points is shown as the red line in the figure below. The black line is the actual trajectory of movement.) when the positioning stage moves at full stroke. Detection method: Place the micrometer on the positioning stage, with the pointer held against the reference block, let the positioning stage move at full stroke, and measure its maximum displacement, which is the straightness.

Meaning of Straightness of MISUMI Manual Positioning StageDetection Method of MISUMI Manual Positioning Stage

Usage Method
■Installation Method of X-Axis Positioning Stage
   When mounting the positioning stage to the base, basically it is mounted by moving the positioning stage surface. Refer to the following diagram.
Standard Installation Method of MISUMI Manual X-Axis Positioning Stage
The above diagram is for demonstration purpose only. Refer to each catalog or 3D data for detailed shapes and specifications of the positioning stage.

■Mounting Posture
DiagramHorizontal Installation Diagram of MISUMI X-Axis Positioning Stage Inverted Installation Diagram of MISUMI X-Axis Positioning Stage  Side-Mounted Horizontal Installation Diagram of MISUMI X-Axis Positioning Stage Side-Mounted Vertical Installation Diagram of MISUMI X-Axis Positioning Stage
Mounting PostureHorizontalInvertedSide-Mounted HorizontalSide-Mounted Vertical
Load Resistance Characteristics
Horizontal, inverted, side-mounted horizontal or side-mounted vertical installation options are available. Other installation methods should be given more attention.
Load capacity and accuracy will change greatly depending on the mounting posture.
○:Same as horizontal load capacity.
△:About 1/3 of the horizontal load capacity is the approximate standard, if the catalog contains the vertical load capacity, it should be given priority.

■Vertical Use of X-Axis Positioning Stage
  When using the X-axis positioning stage vertically, pay attention to the feed direction, which should not be in the same direction as gravity.
  When using a micrometer knob type positioning stage, note that the positioning stage is reset by extension spring. If the force applied is greater than the spring load, the positioning stage surface may fall. For such occasions, alterations can be used as a solution.
Wrong Usage MethodCorrect Usage Method
(Usually) If the force applied exceeds the tensile load of the spring, the positioning stage surface may slip off because it cannot support the weight.After selecting the alteration of the micrometer knob position change, the positioning stage surface does not fall even when used vertically.
Example of wrongly using MISUMI X-axis positioning stage verticallyExample of correctly using MISUMI X-axis positioning stage vertically
Avoid applying loads that exceed the load carrying range in the vertical direction.
Example of Use
Mechanism name: Sensor position adjustment for detecting the completion of the transducer riveting
MISUMI InCAD Library Case Study on the Use of Economy Series Manual Positioning Stages

Example of Use
Electronics/Home Appliance Automotive Medical
Application Scenario Diagram of MISUMI Manual Positioning Stages in Electronics and Home Appliance Fields Application Scenario Diagram of MISUMI Manual Positioning Stages in Automotive Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Medical Device Industry
Smart Phones Semiconductor Lithium battery
Application Scenario Diagram of MISUMI Manual Positioning Stages in Smart Phone Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Semiconductor Industry Application Scenario Diagram of MISUMI Manual Positioning Stages in Lithium-Ion Battery Industry
Precautions
■Operating temperature and environment
  Recommended operating environment: 10~50℃, 20~70%RH (no condensation)
  Accuracy assurance environment: 22±5℃, 20~70%RH (no condensation)

■Guiding mechanism
  This positioning stage adopts crossed roller guide as the guiding mechanism. Please refill the lubricant at the right time according to the usage conditions to prevent the life of crossed roller guide from being shortened due to the decrease of lubricant and aging.

■Clamping mechanism
  ①The clamping mechanism of the positioning stage is fixed by the frictional force generated by the fastening screw, so when the applied external force exceeds the frictional force of the clamping mechanism section, it will cause the positioning stage to move. The user should take appropriate measures to avoid movement of the positioning stage surface during use. If clamping reinforcement is required, disc clamping or opposite clamping can be selected.
  ②The holding force is the value of the force that keeps the positioning stage surface from moving in the clamped condition. Since the maximum holding force varies with the tightening torque, please ensure a sufficiently large safety factor when designing.

■Feed mechanism
  The shape of a positioning stage with a micrometer knob installed as shown in the figure below is generally called the standard type. Free selection is possible by combining the installation space, mounting posture, and operation method. However, due to the structure of the product, there are some models where the installation position of the micrometer knob cannot be changed. For details, refer to the [Alteration] at the bottom of each product page.
Micrometer Knob Position Diagram of MISUMI Manual X-Axis Positioning Stage Standard Type

■Flatness of the mounting surface
The upper and lower positioning stage surface may be deformed due to the different flatness of its mounting surface. Deformation of the positioning stage surface may result in gaps, looseness due to failure to obtain the specified preload, or poor sliding due to excessive preload. Therefore, it is recommended that the flatness of the mounting surface be kept at about 5 microns.
Related Products
X-Axis Motorized Positioning Stages XY-Axis Motorized Positioning Stages Z-Axis Motorized Positioning Stages
MISUMI Economy series Electric X-Axis Linear Ball Guide Type Positioning Stages C-XMBS Series MISUMI Economy series Electric X-Axis Linear Ball Guide Type Positioning Stages C-XMBS Series MISUMI Economy series Electric Z-Axis Linear Ball Guide Type Positioning Stages C-XMBS Series
Typical Model: C-XMBS420-L-A-2 Typical Model: C-XYMBS420-L-A-2 Typical Model: C-ZMBS420-L-A-2
Advantages: low price, fast delivery Advantages: low price, fast delivery Advantages: low price, fast delivery

Additional Products in this Category

Tech Support