(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

FCN Connector Cable, Straight Discrete Wire, Selectable Angle Type (Connectors Made by TE Connectivity)

FCN Connector Cable, Straight Discrete Wire, Selectable Angle Type (Connectors Made by TE Connectivity)

Space saving is possible with angle shape / loose wire

  • Connection in Boards
  • PLC
  • Solder
  • Gold Plated

● The angle shape is useful for easy maneuvering in narrow areas.
● Wires are available in a total of 5 colors, with yellow for AC, blue for DC, and red, white and black for multiple purposes.
● Mark tube printing is possible when a custom number is used. 
● Supports sectional color changing of loose wires with "WEB Design Harness Plus." 

· When the mark tube has no printed custom number specified, the connector pin arrangement number is printed. Be careful not to forget to put the custom number on the supported device.
· Hoods may not shut due to cable thickness, however, this does not affect product quality or performance.

Component Page >>Click here.

PDF

Specifications

Loose Wire with Hood Angle:Related Image

Specified Length (m)~ 0.91 ~ 44.1 ~ 10
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.

Connector TypeShape Specification TypeMating Surface and Wiring DirectionOutline Image DrawingWire TypeNumber of CoresSpecified Length (m)
BHFCNA
With Hood
M2.6 Screw
Lock Type

Tyco Electronics
 SAT
(Female Angle)
with Pin No. Insertion
Mark Tube
SBT
(Female Angle)
with Pin No. Insertion
Mark Tube
 Loose Wire with Hood Angle:Related ImageLoose Wire with Hood Angle:Related Image
Female
Mark Tube Only
A
Yellow

B
Blue

C
White

D
Black

E
Red

UL1007
AWG24
Equivalent Product




400.2
~
10
Can be specified by
0.1m
increments
 SAY
(Female Angle / Y Terminal)
with Pin No. Insertion
Mark Tube
SBY
(Female Angle / Y Terminal)
with Pin No. Insertion
Mark Tube
 Loose Wire with Hood Angle:Related ImageLoose Wire with Hood Angle:Related Image
Female
Y Terminal
 SAR
(Female Angle / Round Terminal)
with Pin No. Insertion
Mark Tube
SBR
(Female Angle / Round Terminal)
with Pin No. Insertion
Mark Tube
 Loose Wire with Hood Angle:Related ImageLoose Wire with Hood Angle:Related Image
Female
Round Terminal

More Information

Loose Wire with Hood Angle:Related Image
Loose Wire with Hood Angle:Related Image
Part Number
BHFCNA-SAR-A-40-[0.2-10/0.1]
BHFCNA-SAR-B-40-[0.2-10/0.1]
BHFCNA-SAR-C-40-[0.2-10/0.1]
BHFCNA-SAR-D-40-[0.2-10/0.1]
BHFCNA-SAR-E-40-[0.2-10/0.1]
BHFCNA-SAT-A-40-[0.2-10/0.1]
BHFCNA-SAT-B-40-[0.2-10/0.1]
BHFCNA-SAT-C-40-[0.2-10/0.1]
BHFCNA-SAT-D-40-[0.2-10/0.1]
BHFCNA-SAT-E-40-[0.2-10/0.1]
BHFCNA-SAY-A-40-[0.2-10/0.1]
BHFCNA-SAY-B-40-[0.2-10/0.1]
BHFCNA-SAY-C-40-[0.2-10/0.1]
BHFCNA-SAY-D-40-[0.2-10/0.1]
BHFCNA-SAY-E-40-[0.2-10/0.1]
BHFCNA-SBR-A-40-[0.2-10/0.1]
BHFCNA-SBR-B-40-[0.2-10/0.1]
BHFCNA-SBR-C-40-[0.2-10/0.1]
BHFCNA-SBR-D-40-[0.2-10/0.1]
BHFCNA-SBR-E-40-[0.2-10/0.1]
BHFCNA-SBT-A-40-[0.2-10/0.1]
BHFCNA-SBT-B-40-[0.2-10/0.1]
BHFCNA-SBT-C-40-[0.2-10/0.1]
BHFCNA-SBT-D-40-[0.2-10/0.1]
BHFCNA-SBT-E-40-[0.2-10/0.1]
BHFCNA-SBY-A-40-[0.2-10/0.1]
BHFCNA-SBY-B-40-[0.2-10/0.1]
BHFCNA-SBY-C-40-[0.2-10/0.1]
BHFCNA-SBY-D-40-[0.2-10/0.1]
BHFCNA-SBY-E-40-[0.2-10/0.1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCN2 Cable color Cable wiring direction (CN1 connector) Cable type Specified Length
(m)

-

1 Piece(s) 5 Day(s) or more Circular TerminalYellowLeft SideA0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalBlueLeft SideB0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalWhiteLeft SideC0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalBlackLeft SideD0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalRedLeft SideE0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offYellowLeft SideA0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offBlueLeft SideB0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offWhiteLeft SideC0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offBlackLeft SideD0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offRedLeft SideE0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalYellowLeft SideA0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalBlueLeft SideB0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalWhiteLeft SideC0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalBlackLeft SideD0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalRedLeft SideE0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalYellowRight SideA0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalBlueRight SideB0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalWhiteRight SideC0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalBlackRight SideD0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Circular TerminalRedRight SideE0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offYellowRight SideA0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offBlueRight SideB0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offWhiteRight SideC0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offBlackRight SideD0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Cut offRedRight SideE0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalYellowRight SideA0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalBlueRight SideB0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalWhiteRight SideC0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalBlackRight SideD0.2 ~ 10

-

1 Piece(s) 5 Day(s) or more Y terminalRedRight SideE0.2 ~ 10

Loading...

  1. 1

Compatible Wire

Connector Type Wire Size
Soldered Type Loose wire of AWG23 ~ AWG30, or 0.2 mm2 ~ 0.05 mm2
Pressure Welding Type 1.27 mm Pitch Flat Cable AWG28, AWG30
* Loose wires cannot be used. (Fused cables can be used)

Material / Finish

Item Material / Finish
Insulator Polyester
Contact Copper Alloy / Gold Plating

Contact Arrangement Diagram


Electrical Properties

Item Characteristics Conditions
Rated Current 3 ADC (1 ADC for pressure welded type) or lower Allowable current of single contact after coupling
Rated Voltage 250 VAC or less Allowable voltage within operating temperature range
Contact Resistance 15 mΩ or less Measured at 6 VDC, 0.3 A
Insulation Resistance 1000 MΩ or more Between terminals and between ground & terminal are measured at 500 VDC
Withstand Voltage 500 VAC / 1 min No abnormality to be found when 500 VDC is applied for 1 minute to the same location as the insulation resistance measurement.
Operating Temperature Range -55°C ~ +85°C -

Electrical Properties

Item Characteristics Conditions
Insertion and Extraction Force Per Single Pole Insertion Force: 312 g or less, Extraction Force: 50 g or more When male and female are inserted and extracted, the total extraction force is divided by each core number to convert into force per single pole
Vibration Resistance No interruption to power supplies of 1 μs or more. Matching contact resistance. After mounting of compatible electric wires, under conditions of DC current of 100 mA passing through the terminals, it will provide vibrations at a total amplitude of 1.5 mm and
vibration frequency of 10 ~ 55 Hz (1 minute reciprocal) in right angled 3 directions for 2 hours.
Insertion and Removal Durability Contact resistance at 20 mΩ or less. Matching insertion and extraction force per single pole. Perform insertion-extraction 500 times at a speed of 600 times / hour.

Environmental Properties

Item Characteristics Conditions
Temperature Resistance Matching contact resistance, insulation resistance and withstand voltage. Performs 5 cycles of -55°C ±0.3 for 30 minutes, 25°C ±10.5 for 10 ~ 15 minutes, 85°C ±0.3 for 30 minutes and 25°C ±10.5 for 10 ~ 15 minutes consecutively.
Humidity Resistance Matching contact resistance of 100 MΩ or more, insulation resistance and withstand voltage. Remove after placing in conditions of temperature 40 ±2°C and relative humidity of 90 ~ 95% for 96 hours, remove water droplets and then leave at room humidity conditions for between 1 and 2 hours.
Corrosion Resistance Contact resistance at 20 mΩ or less. After testing for 48 hours at saltwater concentration of 5% and temperature of 35°C, wash salt encrustation off with water and let dry.

Connector x Hood Combination Table

Hood Connector Resin Hood Zinc Die-cast Hood
Standard Screw Long Screw Hood for Relay
FCN-360C0**-B FCN-360C0**-E FCN-360C0**-C FCN-360C040-H-E
Male Solder Type Connectors FCN-361P0**-AU ○ (8-, 16-core not available) ○ (8-, 16-core not available) ○ (40-core only)
Female Solder Type Connectors FCN-361J0**-AU ○ (8-, 16-core not available) ○ (8-, 16-core not available) ○ (40-core only)
Pressure Welding Type Connector FCN-367J0**-AU-F x x x x
○ = Combination available x = Combination unavailable
・Connectors can be coupled if they have the same core numbers and are a combination of male <--> female.
・ When connecting hood to hood without using a relay hood, use a connecting fixing bracket.

Basic Information

Connector type FCN Connector manufacturer AMP Connector Shape Angle
Machining Method Solder Cable shape Discrete wire Hood Plastic
Hood screw M2.6 screw lock CN1 Female Number Of Cores 40
Cable rated voltage(V) 300 Cable standard (UL/CSA) UL / CSA AWG 24
Notes Please see the catalog for more information on mating surface and wiring direction.

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)