(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

300 V UL Standard Intermittently Bonded Cable (MAST-SFKK-SGR-30-1)

300 V UL Standard Intermittently Bonded Cable MAST-SFKK-SGR-30-1

Click this image to zoom it.

Move the mouse over the image to zoom

300 V, UL standard ribbon cable, conductor cross-sectional area: 0.08 mm2, AWG size (AWG): 28

  • VW-1
  • ULAWM
  • 300 V

● Misumi original flat cable.
● Suitable for wiring between devices as it is very soft.
● Flat cable that has both fused and unfused portions, better for internal wiring compared to 100% fused-model flat cables.
● It can be pressure welded to 2.54 pitch MIL connectors (MIL-C-83503 Standard).

· This product can be used in computers, peripheral devices, communication devices and office equipment.
* For cables in stock, please keep in mind that because we cut them to the specified size,
they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.
* This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

(i)Caution

  • Some products are scheduled to be discontinued as soon as supplier is out of stock.Please check the quotation and order screen for details.

PDF

Part Number

Configured Part Number is shown.

MAST-SFKK-SGR-30-1

Specifications

300 V UL Standard Intermittently Bonded Cable:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

MAST-SFKK-SGR
Shape SpecificationIntermittent Bonded Type
Rated Voltage300V
Operating Temperature Range0 ~ 105°C
Standard AcquiredULAWM2651
Insulation MaterialPVC

1 Piece Unit 1 Roll Unit
Model NumberNumber of CoresTotal Length
(m)
MAST-SFKK-SGR
(Intermittent Bonded)
661
8
10
14
16
20
24
26
30
34
36
40
50
60
64

Model NumberNumber of CoresTotal Length
(m)
Sample Provided
MAST-SFKK-SGR
(Intermittent Bonded)
61
/
5
/
10
-
8-
10-
14-
16-
20
24-
26-
30-
34-
36-
40-
50-
60-
64-

More Information

Specifications
Model NumberNumber of CoresTotal Length
(m)
SizeConductor
(Strands / mm)
Span
(mm)
Overall Width
(mm)
Conductor Resistance
Ω/km (20 °C)
Insulation Properties
MΩkm
Withstand Voltage
(V / Min)
Allowable Current
A (30 °C)
Capacitance
(Approx. pF / m)
Characteristic Impedance
Approx. Ω
Propagation Delay
Approx. ns / m
Near-end
Crosstalk
Approx. %
Flame
Retardance Properties
Approximate
Mass
kg / roll
MAST-SFKK-SGR
(Intermittent Bonded)
61
/
5
/
10
/
61
(1 Roll)
AWG28
(0.08 mm2)
7/0.127
Tin Plated Annealed
Copper Wire
6.357.62225
or less
10 or moreAC 200015110854VW-10.7
88.8910.160.93
1011.4312.701.16
1416.5117.781.62
1619.0520.321.86
2024.1325.402.31
2429.2130.482.78
2631.7533.023.01
3036.8338.103.47
3441.9143.183.93
3644.4545.724.16
4049.5350.804.63
5062.2363.505.78
6074.9376.206.94
6480.0181.287.4

*Measurement values are in GSG mode for capacitance, characteristic impedance, propagation delay and near-end crosstalk. * (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.

300 V UL Standard Intermittently Bonded Cable:Related Image

300 V UL Standard Intermittently Bonded Cable:Related Image

Current Reduction Factor
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value. If the ambient temperature is 30 °C or above, the below current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 1 x 0.93 = 0.93 (A) when the ambient temperature is 40 °C

Ambient Temperature (°C)35404550556065
Current Reduction Factor0.970.930.890.860.820.770.73
Ambient Temperature (°C)707580859095100
Current Reduction Factor0.680.630.580.520.450.370.26

Part Number
MAST-SFKK-SGR-30-1
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Number Of Cores
(Core)
Finished outer diameter
(mm)

MYR 20.98

1 Piece(s) 4 Day(s) or more 13038.1

Loading...

  1. 1

Basic Information

Conductor Cross Section(mm2) 0.08 AWG size(AWG) 28 Rated Voltage 300V
Shield None Representative Standard UL

Please check the type/dimensions/specifications of the part MAST-SFKK-SGR-30-1 in the 300 V UL Standard Intermittently Bonded Cable series.

Products like this...

Part Number
MAST-SFKK-SGR-10-61
MAST-SFKK-SGR-16-1
MAST-SFKK-SGR-16-10
MAST-SFKK-SGR-30-10
MAST-SFKK-SGR-30-5
MAST-SFKK-SGR-30-61
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Number Of Cores
(Core)
Finished outer diameter
(mm)

MYR 285.49

1 Piece(s) 4 Day(s) or more 611012.7

MYR 11.54

1 Piece(s) 4 Day(s) or more 11620.32

MYR 90.52

1 Piece(s) 4 Day(s) or more 101620.32

MYR 133.64

1 Piece(s) 4 Day(s) or more 103038.1

MYR 85.58

1 Piece(s) 4 Day(s) or more 53038.1

MYR 694.15

1 Piece(s) 4 Day(s) or more 613038.1

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)