300 V UL Standard Ribbon Cable (MAST-SFL-BGR-34-10)

300 V UL Standard Ribbon Cable MAST-SFL-BGR-34-10

Move the mouse over the image to zoom

300 V UL Standard Bridge Model

  • VW-1
  • ULAWM
  • 300 V

● Misumi original flat cable.
● Suitable for wiring between devices as it is very soft.
● It can be pressure welded to 2.54 pitch MIL connectors (MIL-C-83503 Standard).

· This product can be used in computers, peripheral devices, communication devices and office equipment.
· Be careful not to confuse specified length and quantity when ordering.
* For cables in stock, please keep in mind that because we cut them to the specified size,
they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter]
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.
* This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

(i)Caution

  • Some products are scheduled to be discontinued as soon as supplier is out of stock.Please check the quotation and order screen for details.

PDF

Part Number

Configured Part Number is shown.

MAST-SFL-BGR-34-10

Configured Specifications

Overall Length(m)10Conductor Cross Section(mm2)0.08
AWG size(AWG)28Number Of Cores(Core)34
Finished outer diameter(mm)43.18Rated Voltage300V
ShieldNoneRepresentative StandardUL

Specifications

300 V UL Standard Ribbon Cable:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

MAST-SFL-BGR
Shape SpecificationBridge Type
Rated Voltage300V
Operating Temperature Range0 ~ 105°C
Standard AcquiredULAWM2651
Insulation MaterialPVC

Model NumberNumber of CoresTotal Length
(1 roll) * Meter increments
MAST-SFL-BGR
(Bridge)
61
/
5
/
10
/
61
(1 Roll)
8
10
14
16
20
24
26
30
34
36
40
50
60
64

More Information

Specifications
Model NumberNumber of CoresTotal Length
(m)
SizeConductor
(Strands / mm)
Span
(Approx. mm)
Overall Width
(mm)
Conductor Resistance
Ω/km (20 °C)
Insulation Properties
MΩkm
Withstand Voltage
(V / Min)
Allowable Current
A (30 °C)
Capacitance
(Approx. pF / m)
Characteristic Impedance
Approx. Ω
Propagation Delay
Approx. ns / m
Near-end
Crosstalk
Approx. %
Flame
Retardance Properties
Approximate
Mass
kg / roll
MAST-SFL-BGR
(Bridge)
61
·
5
·
10
·
61
(1 Roll)
AWG28
(0.08 mm2)
7/0.127
Tin Plated Annealed
Copper Wire
6.35 7.62 225
or less
10 or moreAC 200015210654VW-10.7
88.89 10.16 0.93
1011.43 12.70 1.16
1416.51 17.78 1.62
1619.05 20.32 1.86
2024.13 25.40 2.31
2429.21 30.48 2.78
2631.75 33.02 3.01
3036.83 38.10 3.47
3441.91 43.18 3.93
3644.45 45.72 4.16
4049.53 50.80 4.63
5062.23 63.50 5.78
6074.93 76.20 6.94
6480.01 81.28 7.4
*Measurement values are in GSG mode for capacitance, characteristic impedance, propagation delay and near-end crosstalk.
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.

300 V UL Standard Ribbon Cable:Related Image

Current Reduction Factor
Ambient Temperature (°C)35404550556065
Current Reduction Factor0.970.930.890.860.820.770.73
Ambient Temperature (°C)707580859095100
Current Reduction Factor0.680.630.580.520.450.370.26
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 1 x 0.93 = 0.93 (A) when the ambient temperature is 40 °C
Part Number
MAST-SFL-BGR-34-10
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Number Of Cores
(Core)
Finished outer diameter
(mm)

MYR 157.44

1 Piece(s) 4 Day(s) or more 103443.18
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Number Of Cores
(Core)
Finished outer diameter
(mm)
  1. 1

Basic Information

Conductor Cross Section(mm2) 0.08 AWG size(AWG) 28 Rated Voltage 300V
Shield None Representative Standard UL

Please check the type/dimensions/specifications of the part MAST-SFL-BGR-34-10 in the 300 V UL Standard Ribbon Cable series.

Products like this...

Part Number
MAST-SFL-BGR-10-61
MAST-SFL-BGR-20-1
MAST-SFL-BGR-20-10
MAST-SFL-BGR-34-5
MAST-SFL-BGR-34-61
MAST-SFL-BGR-36-1
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Number Of Cores
(Core)
Finished outer diameter
(mm)

MYR 285.49

1 Piece(s) 4 Day(s) or more 611012.7

MYR 14.69

1 Piece(s) 4 Day(s) or more 12025.4

MYR 94.46

1 Piece(s) 4 Day(s) or more 102025.4

MYR 94.50

1 Piece(s) 4 Day(s) or more 53443.18

MYR 791.41

1 Piece(s) 4 Day(s) or more 613443.18

MYR 26.23

1 Piece(s) 4 Day(s) or more 13645.72
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Number Of Cores
(Core)
Finished outer diameter
(mm)

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)

Not a MISUMI customer yet? Register & enjoy 50% off your 1st order!* (*T&C apply.)

  • 7 Million Products
  • 2,000 Brands
  • Free CAD downloads
  • Quote/order any time