Removal Tools For SM Connectors

Removal Tools For SM Connectors

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Extraction tool that minimizes the load when extracting contact


● This is a tool for extracting contacts inserted into the housing of SM and NH connectors.
● Weight: 22.59 g
● Manufacturer: J.S.T. Mfg. Co., Ltd


· Once extracted, the contact cannot be used again.
· It cannot be used for other than BYM-001T-P0.6 and BHF-001T-0.8BS contacts.

PDF

Specifications

Removal Tools For SM Connectors:Related Image

More Information

Extraction Method
(1) Insert the extraction tool from the mating side of the housing.
(2) Pull the electric wire with the terminal stop of the housing pushed up.
(3) When you pull the wire, take care not to pull too hard.
(4) If you pull too hard, the housing may become scratched and unusable.
Part Number
SMJ-06
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHS

MYR 298.65

1 Piece(s)Available 1 Day(s) 10

Loading...

  1. 1

Features

● Compact, high-density relay nylon connectors, widely used in FA devices, etc.
● Due to the installation of the lock mechanism after bonding, a configuration is formed that prevents an undoing of the bond caused by possible vibration.
● The good quality and stability of use are due to the SM Connectors having UL / CSA / TUV standards.
UL: E60389
CSA: LR20812
TÜV: R75050

Specifications

Item Content
Rated Voltage 250 VAC / VDC
Rated Current 3 A
Withstand Voltage 1,500 VAC (1 minute)
Insulation Resistance 500 MΩ or more
Contact Resistance Initial 10 mΩ or less
After environmental testing 20 mΩ or less
Applicable Electric Wire Range AWG28 ~ 22 (0.08 ~ 0.33 mm2)
Suitable Electric Wire Insulation Outer Diameter 1.7 ~ 3.0 mm
Operating Temperature Range -25 ~ 85°C
Compatible Panel Thickness 0.5 ~ 2.0 mm

Material

Item Material
Housing Nylon 6 (UL94V-0)
Housing Color Black
Crimp Contact Phosphor Bronze / Tin Plated

About Coupling

About Coupling

Basic Information

Applicable type SM Connector Product classification Extraction Tool

Please check the type/dimensions/specifications of the part SMJ-06 in the Removal Tools For SM Connectors series.

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)