(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Kindly be informed that it will be peak period in conjunction with the Chinese New Year festive season. Delivery pickup upon 25 January 2025 estimated would arrive after CNY holidays. Please expect slight delay for orders shipped during this peak season and we thank you for your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

VCT531BX

VCT531BX

Click this image to zoom it.

Move the mouse over the image to zoom

  • VCT531BX
  • VCT531BX

600 V Mobile Power Supply Cable Using Braided Conductor

  • Oil-Resistant
  • Strand Wire
  • Braided Conductor
  • 600 V

* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Part Number

Configured Part Number is shown.

Specifications

VCT531BX:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model NumberSection Area (mm2)Number of Cores
VCT531BX0.752
3
4
6
8
10
12
16
20
30
1.252
3
4
6
8
10
12
16
20
30
2.02
3
4
6
8
10
12
16
30
20


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
 

More Information

VCT531BX:Related ImageVCT531BX:Related Image

VCT531BX:Related Image

VCT531BX:Related Image

Specifications

Model NumberSection Area
( mm2) *1
Number of CoresTotal LengthAWG
Reference
Strand
Structure
(See Figure)
Wire Core
Count
*4
Finish
Outer Diameter
(mm)
Estimated
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecification
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
VCT531BX0.7521
~
100
(Specify 1 m
Increments)
18Core / Layer
Strand
29.61201429.2 or less50 or moreAC
3000
96/0.101.6N/A0.8PVC3.21.7PVC
3310.5140121.8
4411.5160111.8
6613.522081.9
8816.029572.1
101017.533072.2
121218.036562.2
161620.045062.3
202022.055552.4
303026.079052.7
1.25216210.51451917.4 or less50 or moreAC
3000
112/0.122.20.83.61.8
3311.5165171.8
4412.5200161.9
6615.0280122.0
8817.537092.2
101019.041092.2
121219.546082.3
161621.558082.4
202024.571572.5
303028.5101062.7
2.0214211.01802711.1 or less50 or moreAC
3000
176/0.122.40.84.01.8
3312.5215231.9
4413.5255201.9
6616.5365162.1
8819.0480132.3
101021.0550132.4
121221.0605122.4
161624.5775112.6
302026.595592.7
203031.5137083.0


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 

Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.880.750.580.33
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40°C, 0.75mm2 2-core: 14 × 0.88 = 12.32 (A) 
 
Structural Drawing
Number of Core LinesWire Core Identification Method
4-core or lessInsulator Coloring Method
(In the order of black, white, red, and green)
5-core or moreNumbering Method
Numbers 1, 2, 3, 4... are consecutively printed on the surface of the black insulator
Part Number
VCT531BX-1.25-2-[1-99/1]
VCT531BX-1.25-4-[1-99/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Number Of Cores
(Core)

-

1 Piece(s) 3 Day(s) or more 1 ~ 992

-

1 Piece(s) 3 Day(s) or more 1 ~ 994

Loading...

  1. 1

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)