(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

UL2464FA UL Standard

UL2464FA UL Standard

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

300 V UL AWM2464 compatible flexible signal cable. (Twisting test for cableveyor more than 10 million times)

  • VW-1
  • ULAWM
  • Strand Wire
  • Thinned Wire Conductor
  • 300 V

·This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Part Number

Configured Part Number is shown.

UL2464FA-23-16-[1-100/1]

Specifications

UL2464FA UL Standard:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model NumberAWG SizeNumber of Cores
UL2464FA252
3
4
6
8
10
12
16
20
232
3
4
6
8
10
12
16
20
202
3
4
6
8
10


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]

More Information

UL2464FA UL Standard:Related ImageUL2464FA UL Standard:Related Image

UL2464FA UL Standard:Related Image

UL2464FA UL Standard:Related Image
UL2464FA UL Standard:Related Image

Specifications

Model NumberAWG
Size
Number of CoresEstimated
Section Area
( mm2) *1
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided *4
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
UL2464 (FA)2520.2Core / Layer
Stranding
24.1203.58105 or less1,000 or more200040/0.080.58Tin0.2Fluorine (ETFE)0.981.0PVCULAWM2464-
334.3243.10-
444.5282.77-
665.1372.34-
885.7462.05-
10106.3551.91-
12126.9651.62-
16166.7711.43-
20207.4901.43-
2320.324.4254.7069.5 or less60/0.080.720.21.12-
334.6304.07-
444.9353.63-
665.5453.07-
886.2602.69-
10106.9702.50-
12127.6832.13-
16167.4921.88-
20208.11151.88-
2020.525.0336.9740.1 or less104/0.080.940.251.44-
335.3416.04-
445.6505.39-
666.5674.55-
887.4854.00-
10108.21053.72-


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 
 
Current Reduction Factor
Ambient Temperature (°C)304050607080
Current Reduction Factor1.000.910.820.710.580.41
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG25 2-core when the ambient temperature is 40°C
3.58 × 0.91 = 3.257 (A)

Part Number
UL2464FA-23-16-[1-100/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Shield Representative Standard Sheath (outer coating) color Sheath (outer coating) material Insulation body materials Other properties

-

1 Piece(s) 4 Day(s) or more 1 ~ 1000.323167.4300VNoneULBlackPVCFluorineElastic, Vibration-resistant

Loading...

  1. 1

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)