(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

UL2464SSB UL Standard with Shield

UL2464SSB UL Standard with Shield

300 V shielded cable for fixed signals, CL3/ULAWM2464/c-UL standard compliant, with excellent oil resistance.

  • c-UL
  • VW-1
  • ULAWM
  • ULLISTED
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • 300 V

· Those other than AWG18 2 ~ 4-core are twisted pairs.
· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Part Number

Configured Part Number is shown.

UL2464SSB-24-50-[1-99/1]

Specifications

UL2464SSB UL Standard with Shield:Related Image

Model NumberAWG SizeCore Number / Pair Number
1P = 2 Cores
Total Length
or
Specified Length
UL2464SSB242 (1P)1
~
100
(Specify 1 m
Increment)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
14 (7P)
16 (8P)
20 (10P)
24 (12P)
30 (15P)
36 (18P)
40 (20P)
50 (25P)
64 (32P)
222 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
14 (7P)
16 (8P)
20 (10P)
24 (12P)
30 (15P)
36 (18P)
40 (20P)
50 (25P)
202 (1P)
4 (2P)
6 (3P)
8 (4P)
10 (5P)
12 (6P)
16 (8P)
182
3
4


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]

More Information

UL2464SSB UL Standard with Shield:Related Image
UL2464SSB UL Standard with Shield:Related Image
UL2464SSB UL Standard with Shield:Related Image

Specifications
Model NumberAWG
Size
Core Number * 1Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided* 5
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
UL2464SSB242 (1P)0.2Twisted Pair24.8394.888.310.0200011/0.160.60Tin0.3PVC1.20.9PVCULAWM2464
CL3
c-UL
4 (2P)46.4543.61.0
6 (3P)66.6613.11.0
8 (4P)87.1722.71.0
10 (5P)107.7822.41.0
12 (6P)128.4962.31.1
14 (7P)148.41022.21.1
16 (8P)169.01112.11.1
20 (10P)2010.51401.91.2
24 (12P)2410.81531.81.2
30 (15P)3012.01861.61.3
36 (18P)3612.82201.51.4
40 (20P)4013.42361.41.4
50 (25P)5014.62801.31.4
64 (32P)6416.43501.11.6
222 (1P)0.325.2466.457.217/0.160.760.321.40.9
4 (2P)47.0664.91.0
6 (3P)67.3774.11.0
8 (4P)87.9903.71.0
10 (5P)108.71093.31.1
12 (6P)129.61303.11.2
14 (7P)149.61363.01.2
16 (8P)1610.21552.81.2
20 (10P)2011.91862.61.3
24 (12P)2412.32082.41.3
30 (15P)3013.72532.21.4
36 (18P)3614.32882.01.4
40 (20P)4015.03131.81.4
50 (25P)5016.93861.71.6
202 (1P)0.525.8608.636.027/0.160.960.321.61.0
4 (2P)48.0826.61.0
6 (3P)68.6985.61.0
8 (4P)89.21205.01.1
10 (5P)109.71444.41.2
12 (6P)1210.51644.21.2
16 (8P)1611.21963.81.2
1820.75Core Layer Stranding26.45311.623.634/0.181.210.351.90.9
336.7659.80.9
447.1808.90.9


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other

Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.890.770.630.44
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG24 2-core when the ambient temperature is 40°C
4.8 x 0.89 = 4.27 (A)

UL2464SSB UL Standard with Shield:Related Image
UL2464SSB UL Standard with Shield:Related Image
Part Number
UL2464SSB-24-50-[1-99/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)

-

1 Piece(s) 2 Day(s) or more 1 ~ 99

Loading...

  1. 1

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)