(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

FKEV-SB 100 V or Less with Shield Instrumentation (Part Numbers)

FKEV-SB 100 V or Less with Shield Instrumentation

Click this image to zoom it.

Move the mouse over the image to zoom

For Weak Current Circuit Signal / Instrumentation Cable

  • For Signal
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • Less than 100 V

● Polyethylene, more electrically stable than PVC, is used for insulation.
The Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

Specifications

FKEV-SB 100 V or Less with Shield Instrumentation:Related Image

Model NumberSection Area
(mm2)
Number of Pairs
1P = 2 Cores
Total Length
or
Specified Length
FKEV-SB
(Twisted Pair Type)
0.31P1
~
100
(Specify 1 m
Increment)
2P
3P
5P
7P
10P
0.51P
2P
3P
5P
7P
10P
0.751P
2P
3P
5P
10P
1.251P
2P
3P
5P
10P


Be sure to read the following precautions when you place an order.
For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* Length in meters is included within the model number. Always specify quantity as number of units, not as meters.
* All listed unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* Check the indications for number of cores, pair number, core / pair number, and
pair number / core when ordering (check the Specification Table for number of wire cores). 1P (1 PS) is "x 2-core".
* Allowable current is to be used only as a reference value and is not guaranteed.

More Information

FKEV-SB 100 V or Less with Shield Instrumentation:Related Image
FKEV-SB 100 V or Less with Shield Instrumentation:Related Image
FKEV-SB 100 V or Less with Shield Instrumentation:Related Image

Specifications
Model NumberSection Area
( mm2) *1
Number of Pairs
1P = 2 Cores
AWG
Estimated
Size *1
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecification
Allowable Current
A (30°C)* 2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3Thickness
(mm)
Material *3Thickness
(mm)
Material *3
FKEV-SB
(Twisted Pair Type)
0.31P22Twisted Pair25.2402.064.4 or less10,000 or more1000 VAC12/0.180.7Tin0.3PE1.31.0 PVCN/A
2P46.9621.61.0
3P67.4701.41.0
5P109.11001.31.1
7P149.91231.11.1
10P20111701.01.1
0.51P2026.1503.338.7 or less20/0.180.950.41.751.0
2P48.4802.71.0
3P69.41052.41.1
5P1011.51502.11.2
7P1412.62091.81.2
10P2014.32601.71.3
0.751P1826.8605.925.8 or less30/0.181.10.52.11.0
2P49.41004.71.1
3P610.91504.21.2
5P1012.62103.71.2
10P2016.13603.01.3
1.251P1627.7901017.2 or less1500 VAC7/0.451.30.62.551.0
2P410.91708.01.1
3P612.52207.21.2
5P1014.93306.41.3
10P2020.25905.21.5


*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 Allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material; P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.890.750.580.34
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value with 1P of 0.2 mm2 at the ambient temperature of 40°C 2.0 x 0.89 = 1.78 (A)

FKEV-SB 100 V or Less with Shield Instrumentation:Related Image

Wire Core Identification Table
Pair Number12345678910
Class 1 Wire CoreBlueYellowGreenRedPurpleBlueYellowGreenRedPurple
Class 2 Wire CoreWhiteWhiteWhiteWhiteWhiteBrownBrownBrownBrownBrown
Pair Number11121314151617181920
Class 1 Wire CoreBlueYellowGreenRedPurpleBlueYellowGreenRedPurple
Class 2 Wire CoreBlackBlackBlackBlackBlackGrayGrayGrayGrayGray
Part Number
FKEV-SB-0.3-2P-[1-99/1]
FKEV-SB-0.3-3P-[1-99/1]
FKEV-SB-0.5-2P-[1-99/1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Finished outer diameter
(mm)

-

1 Piece(s) 4 Day(s) or more 1 ~ 990.3226.9

-

1 Piece(s) 4 Day(s) or more 1 ~ 99---

-

1 Piece(s) 4 Day(s) or more 1 ~ 990.5208.4

Loading...

  1. 1

Basic Information

Logarithm 2P Rated Voltage For Low Current Circuits Shield Present
Properties Oil resistance Sheath (outer coating) color Black Sheath (outer coating) material PVC
Insulation body materials Polyethylene type Power supply/signal Dual use Other properties Noise Resistance

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)