Small Limit Switch [D4C] (D4C-4302)

Small Limit Switch [D4C] D4C-4302

Compact limit switch excelling in compact size, thin and high seal properties.
[Features]
● Approved by EN (TÜV), UL, CSA, CCC standard. (ask your manufacturer for information on approved models)
● High sealing property compliant with IEC Standard IP67.
● The plunger has a seal packing, a diaphragm and the built-in switch has a protective cap and a triple seal structure.
● 3 m and 5 m cords are used as a standard. Series with cords certified by UL and CSA standards.
● Plunger type enables multiple mountings.
● A series of LED indicator lights (red) is made to facilitate confirmation during operation. (Lights up when not operating as a standard)
● VCTF oil-resistant cord type and pre-wired type products confirm with CE marking. (However this is applicable to the Standard type only).

PDF

Japanese Only

Dimensional Drawing of OMRON Limit Switch

Model D4C-□□01 of Limit Switch

Compact limit switch D4C Model D4C-□□01 outline drawing

*For information on model numbers other than those listed above, please refer to the digital catalog.

Specification Table of OMRON Limit Switch

Performance of Limit Switch

Protective structure of Limit SwitchIP67
Durability*1Mechanical*3Over 10 million times
Electrical*2200,000 times or more (AC125V 5A resistive load)
Allowable Operating Speed0.1mm to 0.5m/s (for plunger type)
1mm to 1m/s (for roller lever type)
Allowable operating frequencyMechanical120 times/min
Electrical30 times/min
Rated Frequency50/60Hz
Insulation resistance100MΩ or more (at DC500V mega)
Contact resistance (initial value)250mΩ or less (with 2m cord)
300mΩ or less (with 3m cord)
400mΩ or less (with 5m cord)
Withstand voltageBetween same-polarity terminalsAC1,000V 50/60Hz 1min
Between live metal parts and earthAC1,500V 50/60Hz 1min
Uimp 2.5kV (EN60947-5-1)
Between each terminal and non-current-carrying metal partsAC1,500V 50/60Hz 1min
Uimp 2.5kV (EN60947-5-1)
Rated insulation voltage (Ui)300V (EN60947-5-1) *5
Pollution level (usage environment)3 (EN60947-5-1)
Short Circuit Protection Device10A fuse type gI or gG (IEC60269)
Conditional Short Circuit Current100A (EN60947-5-1)
Rated sealed thermal current (I the)5A, 4A, 0.5A (EN60947-5-1)
Electric shock protection classClass I (with earth wire)*6
vibrationmalfunction10 to 55Hz, double amplitude 1.5mm *4
Shock ResistantDurabilityUp to 1,000m/s2
malfunctionMaximum 500m/s2* 4
Ambient temperature-10 to +70℃ (but do not freeze)
Ambient humidity35~95% RH
Mass (for D4C-1202)Approx. 360g (with VCTF3m)
approx. 540g (with VCTF5m)

Note: The above values ​​are initial values of Limit Switch.
*1. The durability values ​​are for an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH, but the durability varies depending on the type of load and the magnitude of the current.
*2. Pre-wired type: 1 million operations or more. (DC specification, switching current 0.1A)
*3. Weather-resistant type: 500,000 operations or more.
*4. Plastic rod type excluded.
*5. Pre-wired type: 250V.
*6. Pre-wired type: class III

Structure of Limit Switch

Small limit switch D4C structure diagram
Part Number
D4C-4302
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Environment Plunger Shape Type Boot Seal Roller Lever Shape Type Rod Shape Type Operating Temperature Range
(°C)
Acquired Standards Protection Structure Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Angle to Switching P.T
(deg)
Max. Stroke T.T
(mm)
Max. Angle T.T
(deg)
Contact Type Mechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Lever Length R
(mm)
Cable Specifications Detector element details Indicator Light Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N·m)
Rubber material (scraper) Box shape Conduit size Specification of Terminal Cord / cable length
(m)
Details Type O.D. Mounting system Roller Type Contact format Wiring Specifications AC Rated Voltage DC Rated Voltage AC Electrical Rating details DC Electrical Rating details

MYR 217.63

1 Piece(s) 5 Day(s) or more Plunger TypeStandard[Roller Plungers] Roller PlungerNo---10~70TUV / ENIP6711.771.8-4.8-Single Pole Double Throw1000120DC30V or Less / AC100/125V0.14017.467-VCTF Oil Resistance Code 5m (0.75mm2 4 core Finished Outer Diameter 7.6mm)-No328.5----Ground terminal (micro-load type) included5-φ12×4.4Front mountingStainless steel-based sintered roller1c-----

Loading...

  1. 1
 

Basic Information

Main Body Size Small

Please check the type/dimensions/specifications of the part D4C-4302 in the Small Limit Switch [D4C] series.

Products like this...

Part Number
D4C-1201
D4C-1202
D4C-1203
D4C-4320
D4C-4324
D4C-4332
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Environment Plunger Shape Type Boot Seal Roller Lever Shape Type Rod Shape Type Operating Temperature Range
(°C)
Acquired Standards Protection Structure Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Angle to Switching P.T
(deg)
Max. Stroke T.T
(mm)
Max. Angle T.T
(deg)
Contact Type Mechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Lever Length R
(mm)
Cable Specifications Detector element details Indicator Light Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N·m)
Rubber material (scraper) Box shape Conduit size Specification of Terminal Cord / cable length
(m)
Details Type O.D. Mounting system Roller Type Contact format Wiring Specifications AC Rated Voltage DC Rated Voltage AC Electrical Rating details DC Electrical Rating details

MYR 178.94

1 Piece(s) 2 Day(s) Plunger TypeStandard[Top Plunger] Pin, PlungersNo---10~70EN / TUVIP6711.771.8-4.8-Single Pole Double Throw1000120DC30V or Less / AC240/250V44017.449-VCTF Oil Resistance Code 3m (0.75mm2 4 core Finished Outer Diameter 7.6mm)-No315.7----Ground terminal (general load type) included3Stainless Steel Plungerφ10Front mounting-1c-----

MYR 194.46

1 Piece(s) 2 Day(s) Plunger TypeStandard[Roller Plungers] Roller PlungerNo---10~70EN / TUVIP6711.771.8-4.8-Single Pole Double Throw1000120DC30V or Less / AC240/250V44017.467-VCTF Oil Resistance Code 3m (0.75mm2 4 core Finished Outer Diameter 7.6mm)-No328.5----Ground terminal (general load type) included3-φ12×4.4Front mountingStainless steel-based sintered roller1c-----

MYR 194.46

1 Piece(s) 1 Day(s) Plunger TypeStandard[Roller Plungers] Cross Roller PlungerNo---10~70EN / TUVIP6711.771.8-4.8-Single Pole Double Throw1000120DC30V or Less / AC240/250V44017.467-VCTF Oil Resistance Code 3m (0.75mm2 4 core Finished Outer Diameter 7.6mm)-No328.5----Ground terminal (general load type) included3-φ12×4.4Front mountingStainless Steel Roller1c-----

MYR 229.22

1 Piece(s) 5 Day(s) or more Roller Lever Type (rotation)Standard--Standard--10~70EN / TUVIP675.69-25-65Single Pole Double Throw1000120AC100/125V / DC30V or Less0.14017.46538VCTF Oil Resistance Code 5m (0.75mm2 4 core Finished Outer Diameter 7.6mm)-No------Ground terminal (micro-load type) included5-φ17.5×7Front mountingStainless steel-based sintered roller1c-----

MYR 227.49

1 Piece(s) 6 Day(s) or more Roller lever typeStandard-----10~70EN / CE / GB(CCC) / TUVIP67------1000120-------Roller lever type (high sensitivity type)No-------5Standard type----VCTF oil resistance cord12530125 V AC (0.1 A)30 V DC (0.1 A)

MYR 229.22

1 Piece(s) 2 Day(s) Plunger TypeStandard[Roller Plungers] Seal, Roller PlungersPresence---10~70EN / TUVIP6717.651.8-4.8-Single Pole Double Throw1000120AC100/125V / DC30V or Less0.14017.449-VCTF Oil Resistance Code 5m (0.75mm2 4 core Finished Outer Diameter 7.6mm)-No334.3----Ground terminal (micro-load type) included5-φ12×4.4Front mountingStainless Steel Roller1c-----

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)