(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Electromagnetic Valve for Special Control Equipment Applications, Mechanical Operation Valve, Round Series

Electromagnetic Valve for Special Control Equipment Applications, Mechanical Operation Valve, Round Series

Compact, lightweight, no sticking, mounting posture free, no need for additional oil, withstands high frequency operation, long service life. Many types of voltage, common to each model.
Note: CAD data of this series is being revised. Please wait till the corrections are done.

(i)Caution

  • [Discontinued Information]Part number: The 030E1-2 12 V DC will be discontinued in April 2022.

PDF

Part Number

Configured Part Number is shown.

030E1 AC200V

Drawing

Special Purpose Solenoid Valve Mechanically Actuated Valve Round Series, drawing 01

Single solenoid (standard type) 062E1

 
Special Purpose Solenoid Valve Mechanically Actuated Valve Round Series, drawing 02

Single solenoid (standard type) 062-4E1

 
Special Purpose Solenoid Valve Mechanically Actuated Valve Round Series, drawing 03

Double solenoid (standard type) 062-4E2
Keep solenoid (standard type) 062-4SE2
*: () Is for the keep solenoid.

Product Specifications

ItemPart number
062E1-2062E1-2-11062E1062E1-11062-4E1062E2-2062E2062-4E2062SE2-2062SE2062-4SE2
Number of positions2
Number of ports234234234
Valve FunctionsSingle solenoidDouble solenoidKeep solenoid
Normally closed
(NC standard)
Normally open
(NO option)
Normally closed
(NC standard)
Normally open
(NO option)
Normally closed (NC) and normally open (NO)Normally closed (NC) and normally open (NO)

Basic form and valve function

ItemPart number
062E1-2062E1-2-11062E1062E1-11062-4E1062E2-2062E2062-4E2062SE2-2062SE2062-4SE2
Operating fluidAir
Operating methodLinear Motion Type
Flow rate
Characteristic
Sonic conductance C dm^3 / (s*bar) *10.50.360.50.360.50.36
Effective cross-sectional area [Cv value] mm^22.5 [0.12]1.8 [0.08]2.5 [0.12]1.8 [0.08]2.5 [0.12]1.8 [0.08]
Piping Connection Port Diameter Rc1/4
LubricationNot required
Operating pressure range MPa / *20 to 0.9
Proof pressure resistant MPa1.35
Response time ON/OFF msON30
OFF30
Maximum operating frequency: Hz5
Minimum excitation time required for self-holding ms50
Operating temperature range (atmosphere and operating fluid)°C0 to 60
Mounting DirectionFree
Weight (kg)0.30.50.4

Specifications
*1: The value of sonic conductance is a calculated value, not an actual measurement value.
*2: For holding when not energized, apply a pressure of 0.6 MPa or more for 062E2 and 062-4E2.

ItemSolenoid Form
Single solenoid (E1)Double solenoid (E2)Keep solenoid (SE2)
Voltage range %±10% of operating voltage+10%, -5% of operating voltage
Energization methodContinuous energization typeInstant energization, continuous energization shared type
Insulation TypeType B
Connection MethodGrommet Type
Lead length, mmApprox. 300

Electrical Specifications

Product features details

Compact and lightweight, no sticking, and free mounting orientation

Air flow rate of each series (2,3 ports)

Air flow rate of each series (2,3 ports)

Supply pressure 0.5 MPa (When open air)

Supply pressure 0.5 MPa (When open air)

Compatible cylinder quick reference table

Compatible cylinder quick reference table

1. The □ part of the graph shows the range normally used (cylinder speed 300 to 600 mm/s) 2. This graph shows the measurement results at a supply pressure of 0.5 MPa and a load factor of 0, but with a 0.4 to 0.7 MPa load, with nearly the same results at load factors up to around 30%. 3. Generally, select a valve with a margin of about 50% of the required cylinder speed and use it at a reduced speed with a speed controller
  1. 1. The □ part of the graph shows the range normally used (Cylinder speed 300 to 600 mm/s)
  2. 2. This graph shows the measurement results at a supply pressure of 0.5 MPa and a load factor of 0, but it is almost the same if the load factor is about 0.4 to 0.7 MPa and the load factor is about 30%.
  3. 3. Generally, select a valve with a margin of about 50% of the required cylinder speed, and use a speed controller to reduce the speed.
Cylinder speed of each series / The graph above shows the maximum speed when the cylinder is operated within a supply pressure of 0.5 MPa and a load factor of 30%.

Cylinder speed of each series
The graph above shows the maximum speed when the cylinder is operated within a supply pressure of 0.5 MPa and a load factor of 30%.

Secret story of development

 

It is a product with combining design know-how and production technology cultivated since the manufacturer founding to meet customer needs, and it is developed after undergoing strict inspection.

Part Number
030E1 AC200V
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 220.59

1 Piece(s) 4 Day(s) or more

Loading...

  1. 1
 

Basic Information

Type Electromagnetic Valve Application Single Item Operating Number of Ports 3-port valve
Mounting Orientation Direct Specifications Standard / Oil-Free Number of Solenoids Single
Status at Power Off Self-reset(spring return) Pipe Port Type M Plumbing Thread Nominal M5
Plumbing Direct piping Driving Type Linear Motion Type Poppet CV Value 0.03
Seal Type Soft seal Voltage AC200V

Please check the type/dimensions/specifications of the part 030E1 AC200V in the Electromagnetic Valve for Special Control Equipment Applications, Mechanical Operation Valve, Round Series series.