  • Kindly be informed that it will be peak period in conjunction with the Chinese New Year festive season. Delivery pickup upon 25 January 2025 estimated would arrive after CNY holidays. Please expect slight delay for orders shipped during this peak season and we thank you for your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Polyacetal Float Switch

Polyacetal Float Switch

Polyacetyl type float switch is applied as reed switch. Ideal in detecting oils such as paraffin, lubricating oils etc.

[Features]
· HL-S2 Developed for detecting oils like paraffin, lubricating oils etc. reed switch type float switch flange 27 mm
· Rising liquid level ON type and drop level ON type, these 2 types of switch are lined up.
· When liquid level in the storage tank reaches lowest level, or while controlling the highest upper level, distance between the mounted float switch and highest liquid level is shorter, substantially allowing the usage of increased quantity of liquid.
· HL-201N... It is polyacetyl mainframe system and NBR float switch.
· Slightly bigger than HL-S2 the miniature model

PDF

Japanese Only

Part Number

Configured Part Number is shown.

 
Part Number
HL-201NA
HL-201NB
HL-207A
HL-207B
HL-S2A
HL-S2B
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOperating Voltage Mount Type Standard liquid Direction of Operation Operating Point
(mm)
Full Length
(mm)
Operating Temperature Range
(℃)
Switching current/switching capacity

MYR 257.29

1 Piece(s) 9 Day(s) or more 10Max AC100V/DC100VPF1/8KeroseneON when liquid level rises17.5±244-10~100Max 10VA/10W And Max 0.5A

MYR 257.29

1 Piece(s) 9 Day(s) or more 10Max AC100V/DC100VPF1/8KeroseneON when liquid level falls22.5±244-10~100Max 10VA/10W And Max 0.5A

MYR 300.17

1 Piece(s) 9 Day(s) or more 10Max AC200V/DC200VM10×P1LubricantON when liquid level rises87.0±1.5116-10~80Max 50VA/50W And Max 0.5A

MYR 300.17

1 Piece(s) 9 Day(s) or more 10Max AC200V/DC200VM10×P1LubricantON when liquid level falls89.5±1.5116-10~80Max 50VA/50W And Max 0.5A

MYR 140.47

1 Piece(s) 9 Day(s) or more 10Max AC100V/DC100VM8XP1.25KeroseneON when liquid level rises5.5±1.527-10~100Max 10VA/10W And Max 0.5A

MYR 141.48

1 Piece(s) 9 Day(s) or more 10Max AC100V/DC100VM8XP1.25KeroseneON when liquid level falls8±1.527-10~100Max 10VA/10W And Max 0.5A

Loading...

  1. 1

Basic Information

Detection Method Reed Switch Material (stem) POM Material (float) NBR
Initial contact resistance(mΩ) 300 Cable Specifications UL3266 AWG24 Minimum operating liquid specific gravity 0.7