(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Small Safety Limit Switch [D4N]

Small Safety Limit Switch [D4N]

Click this image to zoom it.

Move the mouse over the image to zoom

  • Small Safety Limit Switch [D4N]
  • Small Safety Limit Switch [D4N]
  • Small Safety Limit Switch [D4N]
  • Small Safety Limit Switch [D4N]
  • Small Safety Limit Switch [D4N]
  • Small Safety Limit Switch [D4N]
  • Small Safety Limit Switch [D4N]

The standard for safety limit switches. A full lineup is offered globally.
[Features]
● Contact configurations include 1NC/1NO, 2NC, 2NC/1NO, and 3NC. (MBB specifications are available for slow action).
● Also available are M12 connector types that reduce labor and make replacement easier.
●Compatible with both general loads and microloads.
● Au-clad contacts with high contact reliability are used as standard.
● Complies with the safety contact requirements of EN115-1, EN81-20, and EN81-50 (slow action types only).
● UL, EN (TÜV), and CCC standards obtained.

PDF

Japanese Only

Dimensional Drawing of OMRON Limit Switch

1 Conduit Type of Limit Switch

Small safety limit switch D4N 1 conduit type outline drawing-1
Small safety limit switch D4N 1 conduit type outline drawing-2

Note: Limit Switch, The dimensional tolerance of all parts not specified in the above dimensional diagrams for each model is ±0.4 mm.
*For the M12 connector, see "1-conduit type, M12 connector type common."

*For information on model numbers other than those listed above, please refer to the digital catalog.

Specification Table of OMRON Limit Switch

Structure of Limit Switch

Small safety limit switch D4N structure diagram

Performance of Limit Switch

Protective structure*1 of Limit SwitchIP67 (EN60947-5-1)
Durability*2MechanicalOver 1 million times
Electrical500,000 times or more (AC250V 3A, resistive load)*3
300,000 times or more (AC250V 10A, resistive load)
Allowable Operating Speed1 to 500 mm/s (D4N-1A20R)
Allowable operating frequencyMaximum 30 times/min
Contact Resistance25mΩ or less
Minimum applicable load*4DC5V 1mA resistive load (N level reference value)
Rated insulation voltage (Ui)300V
Rated Frequency50/60Hz
Electric shock protection classClass II (double insulated)
Pollution level (usage environment)Pollution degree 3 (EN60947-5-1)
Impulse withstand voltage
(EN60947-5-1)
Between same-polarity terminals2.5kV
Between different terminals4kV
Between each terminal and non-current-carrying metal parts6kV
Insulation resistance100MΩ or more
Contact GapMinimum 2 x 2 mm
vibrationmalfunction10 to 55Hz, single amplitude 0.75mm
impactDurability1,000m/s2
malfunction300m/s2
Conditional Short Circuit Current100A (EN60947-5-1)
Rated open thermal current (Ith)10A (EN60947-5-1)
Ambient temperature-30 to +70℃ (but do not freeze)
Ambient humidity95% RH or less
massApproximately 92g (for D4N-1A20R)

Note 1. The above values ​​are initial values of Limit Switch.
   2. Once a load has been switched, a load with a smaller capacity cannot be connected to the contact. This
      may cause the contact surface to become rough and the contact reliability to be impaired.
*1. This protective structure is based on a test method based on the standard (EN60947-5-1), and the sealing performance under the actual usage environment and conditions should be confirmed in advance.
      The switch box body is protected from the intrusion of dust, oil, water, etc., but the operation key insertion port in the head part should not be exposed to cutting chips, oil, water, chemicals,etc., when using the switch. This
      may cause early wear, damage, and failure of Limit Switch.
*2. The durability conditions are at an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
*3. Do not apply AC250V 3A to two or more circuits.
*4. This value may change depending on the switching frequency, environmental conditions, reliability level, etc. Please check with the actual load in advance.

Part Number
D4N-1A32
D4N-1B32
D4N-2A32
D4N-4A32
D4N-4132
D4N-4232
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Main Body Size Environment Plunger Shape Type Roller Lever Shape Type Lever Shape Type Rod Shape Type Acquired Standards Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Angle to Switching P.T
(deg)
Max. Stroke T.T
(mm)
Max. Angle T.T
(deg)
Contact Type Contact Point Type Mechanical Life
(10,000 times)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Lever Length R
(mm)
Detector element details Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N·m)
Conduit size Specification of Terminal Details Type O.D. Mounting system Direction of Operation Roller Type Contact format Built-in Switch Specification AC Rated Voltage DC Rated Voltage

MYR 80.73

1 Piece(s) 5 Day(s) or more Plunger TypeSmallStandard[Roller Plungers] Top, Roller Plunger---TUV / UL / GB(CCC) / EN6.52.8-6-2-circuit Double-break-1500DC125V / DC250V2.53131.583.6-Roller plunger type (resin roller)428.2±0.80PG13.5-1 Conduit Shape 2 Contact Seriesφ9.5×5Front mountingSlow action (direct circuit opening operation included)Plastic Rollers1NC/1NO---

MYR 68.71

1 Piece(s) 5 Day(s) or more Plunger TypeSmallStandard[Roller Plungers] Top, Roller Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-1500DC125V / DC250V2.53131.583.6-Roller plunger type (resin roller)428.2±0.80PG13.5-1 Conduit Shape 2 Contact Seriesφ9.5×5Front mountingSlow action (direct circuit opening operation included)Plastic Rollers2NC---

MYR 90.03

1 Piece(s) 5 Day(s) or more Plunger TypeSmallStandard[Roller Plungers] Top, Roller Plunger---TUV / UL / GB(CCC) / EN6.52.8-6-2-circuit Double-break-1500DC125V / DC250V2.53131.583.6-Roller plunger type (resin roller)428.2±0.8-G1/2-1 Conduit Shape 2 Contact Seriesφ9.5×5Front mountingSlow action (direct circuit opening operation included)Plastic Rollers1NC/1NO---

MYR 80.73

1 Piece(s) 5 Day(s) or more Plunger TypeSmallStandard[Roller Plungers] Top, Roller Plunger---TUV / UL / GB(CCC) / EN6.52.8-6-2-circuit Double-break-1500DC125V / DC250V2.53131.583.6-Roller plunger type (resin roller)428.2±0.8-M20-1 Conduit Shape 2 Contact Seriesφ9.5×5Front mountingSlow action (direct circuit opening operation included)Plastic Rollers1NC/1NO---

MYR 59.06

1 Piece(s) 5 Day(s) or more Plunger TypeSmallStandard[Roller Plungers] Top, Roller Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-1500DC125V / DC250V2.53131.583.6-Roller plunger type (resin roller)428.2±0.8-M20-1 Conduit Shape 2 Contact Seriesφ9.5×5Front mountingSnap action (direct circuit opening operation included)Plastic Rollers1NC/1NO---

MYR 59.06

1 Piece(s) 5 Day(s) or more Plunger TypeSmallStandard[Roller Plungers] Top, Roller Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-1500DC125V / DC250V2.53131.583.6-Roller plunger type (resin roller)428.2±0.8-M20-1 Conduit Shape 2 Contact Seriesφ9.5×5Front mountingSnap action (direct circuit opening operation included)Plastic Rollers2NC---

Loading...

  1. 1
 

Basic Information

Operating Temperature Range(°C) -30::70 Protection Structure IP67 Mechanical Operation Frequency(times/min or Less) 30

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)