(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Pressure sensor with easy-to-read LED display
[Features]
· Pressure status can be checked at a glance using digital and bar displays
· Chattering prevention function (when set to hysteresis mode) prevents incorrect output due to momentary pressure changes
· Perform automatic teaching simply by teaching pressure values for products with acceptable and unacceptable levels of quality
Part Number
Configured Part Number is shown.
E89-F4
E8F2 model
E89-F4 model
* Compatible panel thickness: 1.2 to 4 mm
Item | Type | ||||
---|---|---|---|---|---|
NPN output | E8F2-A01C model | E8F2-B10C model | E8F2-AN0C model | ||
PNP output | E8F2-A01B model | E8F2-B10B model | E8F2-AN0B model | ||
Power supply voltage | 12 to 24 V DC ±10% Ripple (pp) 10% or less | ||||
Current Consumption | 70 mA or less * 1 | ||||
Pressure type | Gauge pressure | ||||
Pressure range | 0 to 100 kPa | 0 to 1 MPa | 0 to -101 kPa | ||
Pressure setting range | 0 to 100 kPa | 0 to 1 MPa | 0 to -101 kPa | ||
Withstand pressure | 400 kPa | 1.5 MPa | 400 kPa | ||
Fluid | Non-corrosive gas, non-flammable gas | ||||
Operating Mode | Hysteresis mode, wind mode, auto teaching mode | ||||
Repeatability (ON/OFF output) | Within ±1% (F.S.) | ||||
Linearity (Linear output) | Within ±1% (F.S.) | ||||
Response Time (ON/OFF output) | 5 ms or less | ||||
Linear output | 1 to 5 V ±5%F.S (Output impedance: 1 kΩ, allowable load resistance: 500 kΩ or more) | ||||
Output format (ON/OFF) | Open collector output (NO/NC) (Depends on NPN/PNP output format) | ||||
Load current | 30 mA or less | ||||
Output applied voltage | 30 V DC or less | ||||
Residual voltage | NPN open collector output type 1 V or less (When the load current is 30 mA) PNP open collector output type 2 V or less (When the load current is 30 mA) | ||||
Display method * 2 | 3.5 digit digital display by LED (red), LED bar display (green), When the output transistor is ON, the orange LED lights up (2 outputs are independent), and the LED unit display (Green) | ||||
Display accuracy | ±3% F.S. ±1 digit or less | ||||
Protection circuit | Reverse connection, load short circuit protection | ||||
Ambient temperature range | During operation: 0 to +55°C, when stored: -10 to +60℃ (However, do not freeze) | ||||
Ambient humidity range | When operating/saving: 35 to 85% RH each (However, no condensation) | ||||
Influence of temperature | ±3% F.S. or less | ||||
Influence of voltage | ±1.5% F.S. or less | ||||
Insulation Resistance | 100 MΩ or more (at 500 V DC mega) Charge unit batch and case | ||||
Withstand Voltage | 1,000 V AC 1 min | ||||
Vibration (durable) | 10 to 500 Hz, double amplitude 1 mm 150 m/s^2, 11 min × 3 sweep in X, Y, Z directions | ||||
Shock (durable) | 300 m/s2 3 times each in the X, Y, and Z directions | ||||
Protective Enclosure | IEC standard IP50 | ||||
Pressure port | R (PT) 1/8 tapered thread and M5 female thread | ||||
Connection method | Pre-wired type (Standard cord length 2 m) | ||||
Cord | UL certification code | ||||
Mass (In packaged state) | Approx. 110 g | ||||
Material | Pressure port | Die-cast aluminum | |||
Case | Heat-resistant ABS | ||||
Accessories | Mounting bracket, instruction manual |
* 1. Approximately 43 mA when operating power saving function.
* 2. Display example of digital display.
Part Number |
---|
E89-F4 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
---|---|---|---|---|
MYR 28.68 | 1 Piece(s) | 2 Day(s) |
Loading...
Type | Panel Mounting Fittings |
---|
Please check the type/dimensions/specifications of the part E89-F4 in the Digital Pressure Sensor [E8F2] series.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy