Non-Contact Temperature Sensor [ES1]

Non-Contact Temperature Sensor [ES1]

[ES1-N]
Measure the temperature without touching the workpiece. Achieves hygienic and efficient temperature control without damaging
[ES1B]
Realizes non-contact temperature measurement at low cost
[ES1C]
Wide measurement range from 0 to 400°C and high environmental resistance

PDF

Dimensional Drawing of OMRON Other Temperature / Humidity Sensors

Model ES1-LP3-N/Model ES1-LP10-N Main Unit of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1-LP3-N/Model ES1-LP10-N Body outline drawing

Model ES1-LW50-N/Model ES1-LW50L-N Main Unit of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1-LW50-N/Model ES1-LW50L-N Body outline drawing

(The ES1-LW50-N does not have the laser output port (6) or laser switch (7).)

Model ES1-LW100-N/Model ES1-LW100L-N Main Unit of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1-LW100-N/Model ES1-LW100L-N Body outline drawing

(The ES1-LW100-N does not have the laser output port (6) or laser switch (7).)

Model ES1B of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1B outline drawing

Model ES1C of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1C outline drawing

Specification Table of OMRON Other Temperature / Humidity Sensors

ES1-N Ratings/Performance of OMRON Other Temperature / Humidity Sensors

ES1-N

typeNo aiming laserWith aiming laser
Model numberModel ES1-LP3-NModel ES1-LP10-NModel ES1-LW50-NModel ES1-LW100-NModel ES1-LW50L-NModel ES1-LW100L-N
Detector elementThermopile
lenssilicon
Wavelength8–14 μm
outputUSB OutputResolution: 0.1°C
Current Output4~20mA/-50~500℃*1
Load impedance 250Ω or less
Resolution 0.24μA
4~20mA/-50~1,000℃*1
Load impedance 250Ω or less
Resolution 0.24μA
4~20mA/-50~500℃*1
Load impedance 250Ω or less
Resolution 0.24μA
4~20mA/-50~1,000℃ *1
Load impedance 250Ω or less
Resolution 0.24μA
Power supply voltageDC12 to 24V/USB bus power (USB bus power only, other than current output possible)
Allowable power supply voltage fluctuation95 to 105% of power supply voltage
Current consumption30mA or less (24V DC)・30mA or less (DC24V, when aiming laser is not used)
・40mA or less (DC24V, when aiming laser is used)
Cable length2m±5cm
Measurement accuracyUSB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 500℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
USB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 1,000℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
USB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 500℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
USB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 1,000℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
Reproducibility・Within 0.5℃・Within 1℃
(measurement temperature: -50 to 0℃)
・Within 0.5℃
(measurement temperature: 0 to 500℃)
・Within 1℃
(measurement temperature: 500 to 1,000℃)
・Within 0.5℃・Within 1℃
(measurement temperature: -50 to 0℃)
・Within 0.5℃
(measurement temperature: 0 to 500℃)
・Within 1℃
(measurement temperature: 500 to 1,000℃)
Temperature Drift・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: 500 to 1,000℃)
・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: 500 to 1,000℃)
Effects of electromagnetic interference *2Electromagnetic field discharge
immunity
Within ±10℃ (80MHz to 1.0GHz)
Conducted interference
immunity
Within ±10℃ (150kHz to 80MHz)
Response TimeCurrent output: 0.14 s or less (95% response, moving average 1)
EmissivityFactory setting: 0.95 Can be changed from 0.100 to 1.999 using the setting tool
Moving average functionFactory setting: 10
Can be changed from 1 to 1,000 using the setting tool
Factory setting: 50 Can be changed from 1 to 1,000
using the setting tool
Factory setting: 10 Can be changed from 1 to 1,000
using the setting tool
Factory setting: 50 Can be changed from 1 to 1,000
using the setting tool
Operating temperature and humidity rangeTemperature: 0 to 55°C, Humidity: 35 to 85% (no condensation)
Storage Temperature Range-20 to 55°C (no condensation)
Vibration resistancemalfunction10~55Hz 20m/s2 3 axis direction 10min
Durability10 to 55Hz, half amplitude 0.75mm, 3 axial directions 2h
Protective structureNo
Compliance standardsCE, KC, FCC, RCM
-IEC60825-1, PSC, FDA
External dimensionsW32mm×H40mm×L58mmW32mm×H40mm×L90.3mmW32mm×H40mm×L60.4mmW32mm×H40mm×L92.7mm
massApprox. 95gApprox. 115gApprox. 95gApprox. 115g
Standard accessoriesInstruction manual, mounting bracket,
power/output cable (2m),
installation gauge
Instruction manual, mounting bracket, power/output cable (2m)

*1. The default range is 0 to +500°C. When using in -50°C to +500°C or -50°C to +1,000°C, the range must be changed using the ES1-TOOLS.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2). In this case, the measurement error is ±10°C.

Model ES1B

itemModel number
Model ES1B
Power supply voltageDC12/24V
Allowable power supply voltage fluctuation90% to 110% of power supply voltage
Current consumption20mA or less
Measurement Temperature Range10~70℃, 60~120℃, 115~165℃, 140~260℃
Accuracy*1±5℃*2±2%PV or ±2℃, whichever is greater
±10℃*2±4%PV or ±4℃, whichever is greater
±30℃*2±6%PV or ±6℃, whichever is greater
±40℃*2±8%PV or ±8℃, whichever is greater
Reproducibility±1%PV or ±1℃, whichever is greater
Temperature Drift±0.4℃/℃ or less
Effects of electromagnetic interferenceField Strength ImmunityWithin ±10℃ (80-800MHz)
Within ±30℃ (800-1000MHz)
Conducted interference immunity±10℃
Measurement distance: Field of view diameter1:1 typ.
Wavelength6.5 to 14.0 μm
Light receiving elementThermopile
Response speedApproximately 300 ms at 63% response
Output Impedance1 to 4 kΩ
Operating Temperature Range-25 to +70°C (no condensation or freezing)
Permitted ambient humidityRelative humidity 35-85%
Vibration resistance (durability)98m/s2 10~55Hz 2h each in X, Y, and Z directions
Impact resistance (durability)300m/s2 3 times each in X, Y, and Z directions
Body MaterialABS resin
Protective structureIP65
Compliance standardsCE marking*3
massApprox. 120g
Lead WireCompensating wire 3m
PVC coating, heat resistant up to 70℃

*1.For K thermocouple characteristics and emissivity of 0.98
*2.Example of temperature change from any reference temperature of the measurement object
    : When corrected to a reference temperature of 50°C,         the accuracy is
        the greater of ±2% PV or ±2°C at 55°C, and ±4% PV or ±4°C at 60°C.*3.EN61326-1: Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

ES1C

itemModel number
Model ES1C
Power supply voltageDC12-24V
Allowable voltage fluctuation range90 to 110% of rated voltage
Current consumption70mA or less
Measurement Temperature Range0~400℃
Measurement accuracy0 to 200℃: ±2℃ 201 to 400℃: ±1% PV (emissivity 0.95)
Effects of electromagnetic interferenceField Strength Immunity±10℃ max
Conducted interference immunity±10℃ max
Response Time100ms/90%
Reproducibility±1% of reading
Wavelength8–14 μm
Light receiving elementThermopile
EmissivityFixed at 0.95
Current OutputDC4 to 20mA Load 250Ω or less
Ambient Temperature RangeDuring use: 0 to +70°C During storage: -20 to +70°C (no freezing or condensation)
Ambient Humidity RangeUse/storage: Relative humidity 35-85%
Vibration resistance (durability)10~55Hz, amplitude 1.5mm, 2h each in X, Y, and Z directions
mass180g
Protective structureIP67 equivalent
Compliance standardsCE marking*

*EN61326-1: Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

Bill of Materials of OMRON Other Temperature / Humidity Sensors

No.name
(1)lens
(2)Mounting bracket screw holes
(3)Tripod screw hole
(4)Power output connector
(5)Micro USB Connector
(6)Laser output port
(7)Laser Switch
(8)Installation gauge fixing hole
Part Number
ES1B 10-70C
ES1B 60-120C
ES1B 115-165C
ES1B 140-260C
ES1C-A40
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOperating Environment Operating Temperature Range
(°C)
Lead Wire Length F
(m)
Lead wire coating material Measurement temperature range
(°C)

MYR 1,427.00

1 Piece(s) 5 Day(s) or more Heat Resistant-25~703Vinyl10 to 70

MYR 1,427.00

1 Piece(s) 9 Day(s) or more Heat Resistant-25~703Vinyl60 to 120

MYR 1,427.00

1 Piece(s) 24 Day(s) or more Heat Resistant-25~703Vinyl115 to 165

MYR 1,427.00

1 Piece(s) 20 Day(s) or more Heat Resistant-25~703Vinyl140 to 260

MYR 2,483.00

1 Piece(s) 5 Day(s) or more Heat Resistant / Water Proofing0~702-0 to 400

Loading...

  1. 1
 

Basic Information

Measurement Object Temperature Operating Humidity Range(%) 35::85 Power supply voltage(V) DC12 to 24

Additional Products in this Category

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)