  • Kindly be informed that it will be peak period in conjunction with the Chinese New Year festive season. Delivery pickup upon 25 January 2025 estimated would arrive after CNY holidays. Please expect slight delay for orders shipped during this peak season and we thank you for your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Non-Contact Temperature Sensor [ES1]

Non-Contact Temperature Sensor [ES1]

[ES1-N]
Measure the temperature without touching the workpiece. Achieves hygienic and efficient temperature control without damaging
[ES1B]
Realizes non-contact temperature measurement at low cost
[ES1C]
Wide measurement range from 0 to 400°C and high environmental resistance

PDF

Dimensional Drawing of OMRON Other Temperature / Humidity Sensors

Model ES1-LP3-N/Model ES1-LP10-N Main Unit of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1-LP3-N/Model ES1-LP10-N Body outline drawing

Model ES1-LW50-N/Model ES1-LW50L-N Main Unit of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1-LW50-N/Model ES1-LW50L-N Body outline drawing

(The ES1-LW50-N does not have the laser output port (6) or laser switch (7).)

Model ES1-LW100-N/Model ES1-LW100L-N Main Unit of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1-LW100-N/Model ES1-LW100L-N Body outline drawing

(The ES1-LW100-N does not have the laser output port (6) or laser switch (7).)

Model ES1B of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1B outline drawing

Model ES1C of OMRON Other Temperature / Humidity Sensors

Non-contact temperature sensor ES1 Model ES1C outline drawing

Specification Table of OMRON Other Temperature / Humidity Sensors

ES1-N Ratings/Performance of OMRON Other Temperature / Humidity Sensors

ES1-N

typeNo aiming laserWith aiming laser
Model numberModel ES1-LP3-NModel ES1-LP10-NModel ES1-LW50-NModel ES1-LW100-NModel ES1-LW50L-NModel ES1-LW100L-N
Detector elementThermopile
lenssilicon
Wavelength8–14 μm
outputUSB OutputResolution: 0.1°C
Current Output4~20mA/-50~500℃*1
Load impedance 250Ω or less
Resolution 0.24μA
4~20mA/-50~1,000℃*1
Load impedance 250Ω or less
Resolution 0.24μA
4~20mA/-50~500℃*1
Load impedance 250Ω or less
Resolution 0.24μA
4~20mA/-50~1,000℃ *1
Load impedance 250Ω or less
Resolution 0.24μA
Power supply voltageDC12 to 24V/USB bus power (USB bus power only, other than current output possible)
Allowable power supply voltage fluctuation95 to 105% of power supply voltage
Current consumption30mA or less (24V DC)・30mA or less (DC24V, when aiming laser is not used)
・40mA or less (DC24V, when aiming laser is used)
Cable length2m±5cm
Measurement accuracyUSB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 500℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
USB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 1,000℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
USB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 500℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
USB output
: Within ±(-8%rdg+1)℃
(measurement temperature: -50 to 0℃)
Within ±1℃
(measurement temperature: 0 to 200℃)
Within ±0.5%rdg℃
(200 to 1,000℃)
Current output
: Difference from USB output is
within (±0.1% output range)℃
Reproducibility・Within 0.5℃・Within 1℃
(measurement temperature: -50 to 0℃)
・Within 0.5℃
(measurement temperature: 0 to 500℃)
・Within 1℃
(measurement temperature: 500 to 1,000℃)
・Within 0.5℃・Within 1℃
(measurement temperature: -50 to 0℃)
・Within 0.5℃
(measurement temperature: 0 to 500℃)
・Within 1℃
(measurement temperature: 500 to 1,000℃)
Temperature Drift・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: 500 to 1,000℃)
・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: -50 to 0℃)
・Within ±0.25℃/℃
(measurement temperature: 0 to 500℃)
・Within ±0.5℃/℃
(measurement temperature: 500 to 1,000℃)
Effects of electromagnetic interference *2Electromagnetic field discharge
immunity
Within ±10℃ (80MHz to 1.0GHz)
Conducted interference
immunity
Within ±10℃ (150kHz to 80MHz)
Response TimeCurrent output: 0.14 s or less (95% response, moving average 1)
EmissivityFactory setting: 0.95 Can be changed from 0.100 to 1.999 using the setting tool
Moving average functionFactory setting: 10
Can be changed from 1 to 1,000 using the setting tool
Factory setting: 50 Can be changed from 1 to 1,000
using the setting tool
Factory setting: 10 Can be changed from 1 to 1,000
using the setting tool
Factory setting: 50 Can be changed from 1 to 1,000
using the setting tool
Operating temperature and humidity rangeTemperature: 0 to 55°C, Humidity: 35 to 85% (no condensation)
Storage Temperature Range-20 to 55°C (no condensation)
Vibration resistancemalfunction10~55Hz 20m/s2 3 axis direction 10min
Durability10 to 55Hz, half amplitude 0.75mm, 3 axial directions 2h
Protective structureNo
Compliance standardsCE, KC, FCC, RCM
-IEC60825-1, PSC, FDA
External dimensionsW32mm×H40mm×L58mmW32mm×H40mm×L90.3mmW32mm×H40mm×L60.4mmW32mm×H40mm×L92.7mm
massApprox. 95gApprox. 115gApprox. 95gApprox. 115g
Standard accessoriesInstruction manual, mounting bracket,
power/output cable (2m),
installation gauge
Instruction manual, mounting bracket, power/output cable (2m)

*1. The default range is 0 to +500°C. When using in -50°C to +500°C or -50°C to +1,000°C, the range must be changed using the ES1-TOOLS.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2). In this case, the measurement error is ±10°C.

Model ES1B

itemModel number
Model ES1B
Power supply voltageDC12/24V
Allowable power supply voltage fluctuation90% to 110% of power supply voltage
Current consumption20mA or less
Measurement Temperature Range10~70℃, 60~120℃, 115~165℃, 140~260℃
Accuracy*1±5℃*2±2%PV or ±2℃, whichever is greater
±10℃*2±4%PV or ±4℃, whichever is greater
±30℃*2±6%PV or ±6℃, whichever is greater
±40℃*2±8%PV or ±8℃, whichever is greater
Reproducibility±1%PV or ±1℃, whichever is greater
Temperature Drift±0.4℃/℃ or less
Effects of electromagnetic interferenceField Strength ImmunityWithin ±10℃ (80-800MHz)
Within ±30℃ (800-1000MHz)
Conducted interference immunity±10℃
Measurement distance: Field of view diameter1:1 typ.
Wavelength6.5 to 14.0 μm
Light receiving elementThermopile
Response speedApproximately 300 ms at 63% response
Output Impedance1 to 4 kΩ
Operating Temperature Range-25 to +70°C (no condensation or freezing)
Permitted ambient humidityRelative humidity 35-85%
Vibration resistance (durability)98m/s2 10~55Hz 2h each in X, Y, and Z directions
Impact resistance (durability)300m/s2 3 times each in X, Y, and Z directions
Body MaterialABS resin
Protective structureIP65
Compliance standardsCE marking*3
massApprox. 120g
Lead WireCompensating wire 3m
PVC coating, heat resistant up to 70℃

*1.For K thermocouple characteristics and emissivity of 0.98
*2.Example of temperature change from any reference temperature of the measurement object
    : When corrected to a reference temperature of 50°C,         the accuracy is
        the greater of ±2% PV or ±2°C at 55°C, and ±4% PV or ±4°C at 60°C.*3.EN61326-1: Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

ES1C

itemModel number
Model ES1C
Power supply voltageDC12-24V
Allowable voltage fluctuation range90 to 110% of rated voltage
Current consumption70mA or less
Measurement Temperature Range0~400℃
Measurement accuracy0 to 200℃: ±2℃ 201 to 400℃: ±1% PV (emissivity 0.95)
Effects of electromagnetic interferenceField Strength Immunity±10℃ max
Conducted interference immunity±10℃ max
Response Time100ms/90%
Reproducibility±1% of reading
Wavelength8–14 μm
Light receiving elementThermopile
EmissivityFixed at 0.95
Current OutputDC4 to 20mA Load 250Ω or less
Ambient Temperature RangeDuring use: 0 to +70°C During storage: -20 to +70°C (no freezing or condensation)
Ambient Humidity RangeUse/storage: Relative humidity 35-85%
Vibration resistance (durability)10~55Hz, amplitude 1.5mm, 2h each in X, Y, and Z directions
mass180g
Protective structureIP67 equivalent
Compliance standardsCE marking*

*EN61326-1: Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

Bill of Materials of OMRON Other Temperature / Humidity Sensors

No.name
(1)lens
(2)Mounting bracket screw holes
(3)Tripod screw hole
(4)Power output connector
(5)Micro USB Connector
(6)Laser output port
(7)Laser Switch
(8)Installation gauge fixing hole
Part Number
ES1B 10-70C
ES1B 60-120C
ES1B 115-165C
ES1B 140-260C
ES1C-A40
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOperating Environment Operating Temperature Range
(°C)
Lead Wire Length F
(m)
Lead wire coating material Measurement temperature range
(°C)

MYR 1,427.00

1 Piece(s) 5 Day(s) or more Heat Resistant-25~703Vinyl10 to 70

MYR 1,427.00

1 Piece(s) 9 Day(s) or more Heat Resistant-25~703Vinyl60 to 120

MYR 1,427.00

1 Piece(s) 24 Day(s) or more Heat Resistant-25~703Vinyl115 to 165

MYR 1,427.00

1 Piece(s) 20 Day(s) or more Heat Resistant-25~703Vinyl140 to 260

MYR 2,483.00

1 Piece(s) 5 Day(s) or more Heat Resistant / Water Proofing0~702-0 to 400

Loading...

  1. 1
 

Basic Information

Measurement Object Temperature Operating Humidity Range(%) 35::85 Power supply voltage(V) DC12 to 24

Additional Products in this Category

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)