(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
[Features]
·Easy setting with DIP switch
·A 2-point alarm type has also been added to the series. Suitable for alarm applications
·Multi-input (thermocouple/platinum resistance thermometer) type is also available
·Easy-to-read digital display with character height of 13.5 mm
Part Number
Configured Part Number is shown.
* The external dimensions are the same for both models with and without alarm.
No alarm type
Alarm type
Power supply voltage | AC100~240V 50/60Hz AC24V 50/60Hz/DC24V | |
---|---|---|
Allowable voltage fluctuation range | 85 to 110% of power supply voltage | |
Power Consumption | 5VA (AC100~240V) 3VA (AC24V)/2W (DC24V) | |
Temperature Controllers input | Thermocouple types: K, J, L Platinum resistance thermometer types: Pt100, JPt100 Thermistor type: E52-THE Thermocouple/Platinum resistance thermometer multi-input type : K, J, L, T, U, N, R, Pt100, JPt100 | |
Temperature Controllers Output | Relay Output | AC250V 3A (resistive load) 1c |
Voltage output (for driving SSR) | DC12V 21mA (with short circuit protection circuit) | |
Temperature Controllers Method | ON/OFF, 2-degree-of-freedom PID (with automatic PID parameter setting function) | |
Alarm Output | AC250V 1A (resistive load) 1a | |
Setting method | Digital setting by front keys | |
Instruction method | 7-segment digital display (character height 13.5 mm) and deviation indication | |
Other features | · Prohibits setting changes (key protect) · Input correction · Display unit switching (℃/°F) · Forward/reverse operation switching · Temperature Controllers range, sensor switching (K/J/L, Pt100/JPt100), thermocouple/platinum resistance thermometer multi-input type switches between thermocouple and platinum resistance thermometer · Control cycle switching · 8 mode alarm output · Sensor abnormality detection (excluding thermistor type) | |
Ambient Temperature Controllers | -10 to +55°C (but no freezing or condensation) / 3-year warranty: -10 to +50°C | |
Ambient humidity | Relative humidity 25-85% | |
Storage Temperature Controllers | -25 to +65°C (but no freezing or condensation) |
Note: Do not use the inverter output as a power supply.
Indication accuracy (ambient temperature 23℃) | Thermocouple: *1 (±1% of indicated value or ±2°C, whichever is greater) ±1 digit or less Platinum resistance thermometer: *2 (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit or less Thermistor: *3 (1%FS) ±1 digit or less | |
---|---|---|
Temperature Controllers effects | Thermocouple (R): (±2% PV or ±10°C, whichever is greater) ±1 digit or less Other thermocouple: (±2% PV or ±4°C, whichever is greater) ±1 digit or less Platinum resistance thermometer: (±1% PV or ±2°C, whichever is greater) ±1 digit or less Thermistor: (±2% FS) ±1 digit or less | |
Voltage Effects | ||
Effects of electromagnetic interference (according to EN61326-1) | ||
Adjustment sensitivity (at ON/OFF control) | 0.2%FS (0.1%FS for thermocouple/platinum resistance thermometer multi-input type) | |
Proportional Band | 1 to 999°C (self-tuning, automatically set by auto-tuning) | |
Integration Time | 1 to 1999s (automatically set by self-tuning and auto-tuning) | |
Differential Time | 1 to 1999s (automatically set by self-tuning and auto-tuning) | |
Alarm output setting range | Absolute value alarm: Same as control setting range Others: 0 to full scale input setting range [unit: °C or °F] Alarm hysteresis: 0.2 °C or °F (fixed) | |
Temperature Controllers Period | 2/20s | |
Sampling Period | 500ms | |
Insulation resistance | 20MΩ or more (at DC500V megger) | |
Withstand voltage | AC2,000V 50/60Hz 1min (between terminals of different polarity live parts) | |
Vibration resistance | malfunction | 10~55Hz 20m/s2 10min each in X, Y, and Z directions |
Durability | 10~55Hz 0.75mm 2h each in X, Y, and Z directions | |
Shock Resistant | malfunction | 100m/s26 directions 3 times each |
Durability | 300m/s26 directions 3 times each | |
lifespan | Electrical | Over 100,000 times (relay output type) |
mass | Approx. 110g (body only) | |
Protective structure | Front IP50, Enclosure Category 2 (according to IEC60529), Rear case IP20, Terminal IP00 | |
Memory Protection | Non-volatile memory (number of writes: 1 million times) | |
EMC | Radiated interference field strength EN55011 Group1 Class ANoise terminal voltage EN55011 Group1 Class AElectrostatic discharge immunity EN61000-4-2 : 4kV contact discharge (Level 2), 8kV air discharge (Level 3) Field strength immunity EN61000-4-3 : 10V/m (80 to 1,000MHz, 1.4 to 2.0GHz amplitude modulated)(Level 3), 10V/m (900MHz pulse modulated) Conducted interference immunity EN61000-4-6 : 3V (0.15 to 80MHz) (Level 2) First transient EN61000-4-4Burst noise immunity: 2kV power line (Level 3), 1kVinput/output signal line (Level 3) Surge immunity EN61000-4-5 : Power line normal mode 1kV common mode 2kV output line (relay output) normal mode 1kV common mode 2kV voltage dip/interruption immunity EN61000-4-11 :0.5 period, 100% (rated voltage) | |
Certification Standards | UL61010-1 (listing compatible) CSA C22.2 No.1010-1 | |
Compliance standards | EN61326-1, EN61010-1, IEC61010-1 |
Part Number |
---|
E5CS-Q1PU-W AC100-240 |
E5CS-R1PDU-W AC/DC24 |
E5CS-R1PU-W AC100-240 |
E5CS-R2TU-W AC100-240 |
E5CS-RPU-W AC100-240 |
E5CS-RTU-W AC100-240 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Input Method | Power Supply Voltage (V) | Control Output 1 | Alarm Output |
---|---|---|---|---|---|---|---|---|
MYR 1,059.23 | 1 Piece(s) | 24 Day(s) or more | Platinum temperature measuring resistor | 100 to 240 VAC | Voltage output (for driving SSR) | 1 alarm | ||
MYR 1,059.23 | 1 Piece(s) | 16 Day(s) or more | Platinum temperature measuring resistor | 24 VAC/DC | Relay | 1 alarm | ||
MYR 1,059.23 | 1 Piece(s) | 5 Day(s) or more | Platinum temperature measuring resistor | 100 to 240 VAC | Relay | 1 alarm | ||
MYR 1,074.75 | 1 Piece(s) | 9 Day(s) or more | Thermocouple / Platinum temperature measuring resistor | 100 to 240 VAC | Relay | 2 alarms | ||
MYR 966.46 | 1 Piece(s) | 9 Day(s) or more | Platinum temperature measuring resistor | 100 to 240 VAC | Relay | No alarm | ||
MYR 966.46 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor | 100 to 240 VAC | Relay | No alarm |
Loading...
Number of Input Points(pcs.) | 1 | Case color | Light Gray |
---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy