Direct Piping3GA1/2/3R and 4GA1/2/3R Series Unit Valve

Direct Piping3GA1/2/3R and 4GA1/2/3R Series Unit Valve

The new 3GA1/2/3R, 4GA1/2/3R series have inherited the legacy 3G/4G series concept and evolved it further.

[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
3GA210R-06N-7
3GA210R-06N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
3GA310R-08N-7
3GA310R-08N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GA210R-06N-7
4GA210R-06N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GA220R-06N-7
4GA220R-06N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GA230R-06N-7
4GA230R-06N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GA310R-08N-7
4GA310R-08N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GA320R-08N-7
4GA320R-08N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
4GA330R-08N-7
4GA330R-08N-[B,​BN,​E00,​E01J,​E01,​E02J,​E02,​E03J,​E03,​E0N,​E0,​E1,​E2N,​E2,​E3,​E20,​E21J,​E21,​E22J,​E22,​E23J,​E23]-7
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber of Ports Number of Solenoids Switching Type Status at Power Off Voltage Pipe Port Type Plumbing Thread Nominal Applicable Cylinder Dia.
(Ø)
Connecting Tube Diameter Manual Equipment Option Connection Tube Diameter (P/R1/R2 Ports) Electrical Wiring Connection Rc (R) Model Details

-

1 Piece(s) 20 Day(s) or more 3-port valveSingle2-position Normally ClosedSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----Grommet Lead Wire-

-

1 Piece(s) 20 Day(s) or more 3-port valveSingle2-position Normally ClosedSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-

-

1 Piece(s) 13 Day(s) or more 3-port valveSingle2-position Normally ClosedSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----Grommet Lead Wire-

-

1 Piece(s) 13 Day(s) or more 3-port valveSingle2-position Normally ClosedSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-

-

1 Piece(s) 21 Day(s) or more 5-port valveSingle2-position exhaustSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----Grommet Lead Wire-

-

1 Piece(s) 21 Day(s) or more 5-port valveSingle2-position exhaustSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-

-

1 Piece(s) 13 Day(s) or more 5-port valveDouble2-position exhaustSelf-holdingDC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----Grommet Lead Wire-

-

1 Piece(s) 13 Day(s) or more 5-port valveDouble2-position exhaustSelf-holdingDC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-

-

1 Piece(s) 13 Day(s) or more 5-port valveDouble[3-Position Closed Center] 3 Position All Ports Blocked[Self-Recovery (Spring Return)] Self-reset(spring return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----Grommet Lead Wire-

-

1 Piece(s) 13 Day(s) or more 5-port valveDouble[3-Position Closed Center] 3 Position All Ports Blocked[Self-Recovery (Spring Return)] Self-reset(spring return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-40 to 80----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-

-

1 Piece(s) 13 Day(s) or more 5-port valveSingle2-position exhaustSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----Grommet Lead Wire-

-

1 Piece(s) 13 Day(s) or more 5-port valveSingle2-position exhaustSelf-reset(differential pressure return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-

-

1 Piece(s) 17 Day(s) or more 5-port valveDouble2-position exhaustSelf-holdingDC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----Grommet Lead Wire-

-

1 Piece(s) 17 Day(s) or more 5-port valveDouble2-position exhaustSelf-holdingDC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-

-

1 Piece(s) 65 Day(s) or more 5-port valveDouble[3-Position Closed Center] 3 Position All Ports Blocked[Self-Recovery (Spring Return)] Self-reset(spring return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----Grommet Lead Wire-

-

1 Piece(s) 65 Day(s) or more 5-port valveDouble[3-Position Closed Center] 3 Position All Ports Blocked[Self-Recovery (Spring Return)] Self-reset(spring return)DC12V / DC24V / AC100V / AC200V / DC5V / DC3VNPT-63 to 100----E00 / E0 / E0N / E01 / E1 / E01J / E2 / E02 / E02J / E2N / E3 / E03 / E03J / E20 / E21 / E21J / E22 / E22J / E23 / E23J / B / BN-
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber of Ports Number of Solenoids Switching Type Status at Power Off Voltage Pipe Port Type Plumbing Thread Nominal Applicable Cylinder Dia.
(Ø)
Connecting Tube Diameter Manual Equipment Option Connection Tube Diameter (P/R1/R2 Ports) Electrical Wiring Connection Rc (R) Model Details

Loading...

  1. 1

Basic Information

Type Electromagnetic Valve Application Single Item Operating Mounting Orientation Direct
Specifications Standard / Oil-Free Plumbing Direct piping Driving Type Pilot-operated Spool
Seal Type Soft seal

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)

Not a MISUMI customer yet? Register & enjoy 50% off your 1st order!* (*T&C apply.)

  • 7 Million Products
  • 2,000 Brands
  • Free CAD downloads
  • Quote/order any time