(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Please note that some of the items may take longer lead time to ship due to Japan New Year holidays (29-Dec-2024 to 5-Jan-2025). Early order placement is recommended. We apologize for the inconvenience caused and appreciate your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Fluoropolymer Pipe Fitting, LQ2 Series, Male Run Tee, Inch Size

Fluoropolymer Pipe Fitting, LQ2 Series, Male Run Tee, Inch Size

Quadruple seal construction fluoropolymer fitting, male run tee.
[Features]
· Material: New PFA.
· Maximum operating pressure (at 20°C): 1.0 MPa.
· Operating temperature: 0 to 200°C.
· The reducer method allows tubing size changes without replacing the body.

(i)Caution

  • For specifications and details, please refer to the catalog.
  • Product images may be representative images. Refer to the catalog for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Male Run Tee LQ2R-M Inch Size Specifications

Male Run Tee Dimensional Drawing

Male Run Tee Dimensional Drawing

(A): Reference dimension after installation
(E): Reference dimension for the inserted tubing from the end surface of the nut

Male Run Tee Dimensional Drawing for Sizes 2, 3

Male Run Tee Dimensional Drawing for Sizes 2, 3

Male Run Tee Dimensional Drawing for Sizes 4, 5

Male Run Tee Dimensional Drawing for Sizes 4, 5

ModelApplicable Tubing Outer DiameterConnection thread
R/NPT
ABEFGHL1L2MN
LQ2R2A-M□1/4 "1/8 "18.5ø4196121834.52219.9-
LQ2R2B-M□3/16 "
LQ2R2C-M□1/8 "
LQ2R2D-M□1/4 "1/4 "16.5
LQ2R2E-M□3/16 "
LQ2R2F-M□1/8 "
LQ2R3A-M□3/8 "1/4 "23.5ø522918244329.526.2-
LQ2R3B-M□1/4 "42.5
LQ2R3C-M□3/8 "3/8 "2343
LQ2R3D-M□1/4 "42.5
LQ2R4A-M□1/2 "3/8 "30ø628112230523633.121
LQ2R4B-M□3/8 "51
LQ2R4C-M□1/2 "1/2 "28.552
LQ2R4D-M□3/8 "51
LQ2R5A-M□3/4 "1/2 "35ø73214283659.542.54026
LQ2R5B-M□1/2 "58.5
LQ2R5C-M□3/4 "3/4 "33.559.5
LQ2R5D-M□1/2 "58.5

Unit: mm

Withstand Pressure and Heat Resistance Performance

Withstand Pressure and Heat Resistance Performance Data

Withstand Pressure and Heat Resistance Performance Data

Applicable Fluids

ChemicalCompatibility
Acetic acid100%Acetic acid
Acetone100%Acetone○ Note)
Ammonium fluoride40%Ammonium fluoride
Ammonium hydroxide30%Ammonium hydroxide
Butyl acetate100%Butyl acetate
Methylene chloride100%Methylene chloride
Hydrochloric acid38%Hydrochloric acid
Hydrofluoric acid50%Hydrofluoric acid
Hydrogen peroxide60%Hydrogen peroxide
Methanol100%Methanol
Methyl ethyl Ketone-Methyl ethyl Ketone
Nitric acid70%Nitric acid
Phosphoric acid86%Phosphoric acid
Caustic potash85%Caustic potash
Sulfuric acid100%Sulfuric acid
Toluene-Toluene○ Note)
Xylene-Xylene
Sodium hydroxide100%Sodium hydroxide
1.1.1-Trichloroethane100%1.1.1-Trichloroethane
Phosphorus pentachloride-Phosphorus pentachloride
Isobutyl alcohol-Isobutyl alcohol○ Note)
Isopropyl alcohol-Isopropyl alcohol○ Note)
Ozone-Ozone
Ethyl acetate-Ethyl acetate○ Note)
Pure water-Pure water
Nitrogen-Nitrogen
Ultrapure water-Ultrapure water
Tmah-Tmah

○: Can be used
The material and fluid compatibility check list provides reference values as a guide only.
Note) Static electricity may be generated. Implement suitable countermeasures.

  • *Fluid temperature indicates compatibility below 200°C.
  • * The material and fluid compatibility check list provides reference values as a guide only, therefore we do not guarantee the application to our product.
  • * The data above is based on the information presented by the material manufacturers.
  • * The manufacturer is not responsible for the accuracy of the data and any damage incurred from the data.

Precautions for piping

1. Use special tools to connect tubing.

Special Tool Outline Drawing

Special Tool Outline Drawing

2. Tighten the nut until it touches the end surface of the body, and then tighten it an additional 1/8 turn to ensure that the nut has reached the end surface. If the nut will not turn any further, then it means a sufficient tightening has occurred. Refer to the proper tightening torques shown below.

Body sizeTorque (N·m)
21.5 to 2.0
33.0 to 3.5
47.5 to 9.0
511.0 to 13.0

*See the manufacturer's catalog for other precautions and important notes before use.

Part Number
LQ2R2A2C-M
LQ2R2A2C-MN
LQ2R2B2C-M
LQ2R2B2C-MN
LQ2R2D2F-M
LQ2R2D2F-MN
LQ2R2E2F-M
LQ2R2E2F-MN
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Type Applicable Tube O.D. (inch) D (D1) Applicable Tube O.D. (inch) D2 Connection Screw Type M (M1) Connection Screw Nominal M (M1) Size of Body

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)1/41/8R1/8B(6A)2

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)1/41/8NPT (Male thread)1/8B(6A)2

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)-1/8R1/8B(6A)2

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)-1/8NPT (Male thread)1/8B(6A)2

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)1/41/8R1/4B(8A)2

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)1/41/8NPT (Male thread)1/4B(8A)2

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)-1/8R1/4B(8A)2

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)-1/8NPT (Male thread)1/4B(8A)2

Loading...

  1. 1

Basic Information

Type Fitting Body Material PFA Thread-to-Pipe Multipoint Connection Type Male Run Tee
Maximum Operating Temperature(°C) 200

Additional Products in this Category

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)