Compact Guide Cylinder MGP Series (Part Numbers)

Compact Guide Cylinder MGP Series

Click this image to zoom it.

Move the mouse over the image to zoom

  • Compact Guide Cylinder MGP Series
  • Compact Guide Cylinder MGP Series
  • Compact Guide Cylinder MGP Series

Compact cylinder with guide.
[Features]
· Shortened guide rod.
· Saves space.
· By reducing the guide rod length by a maximum 22 mm, the machining required to create space between the bottom of the cylinder body and the equipment is reduced.
· Round auto switches and strong magnetic field resistant auto switches can be directly mounted without spacers.
· 4 types of mounting are possible.
· Piping from either direction.

(i)Caution

  • See catalog for specification details.
  • See the manufacturer's catalog for details about auto switches.
  • Product pictures are representations.

PDF

Compact Guide Cylinder MGP Series Specifications

4 Types of Mounting Are Possible, Piping Is Possible from 2 Directions

4 types of mounting / Piping from 2 directions

4 types of mounting / Piping from 2 directions

3 Types of Bearing Can Be Selected

Slide bearing / ball bushing / high precision ball bushing

Slide bearing / ball bushing / high precision ball bushing

Guide Rod Shortened

Shortened guide rod image

Shortened guide rod image

Tube I.D.Guide rod
Shortened dimensionsNew dimensions
ø322215.5
ø40229
ø501816.5
ø631811.5
ø8010.58
ø10010.510.5

 

(Unit: mm)

 

Compared with the slide bearing type, 25 stroke.
(ø32 to ø100 [32‑ to 100‑mm bore size])
(no projection for ø12 to ø25 [12‑ to 25‑mm bore size] 25 stroke)

Specifications

Tube Internal Diameter (mm)121620253240506380100
Operating methodDouble acting type
Applicable fluidsAir
Proof pressure1.5 MPa
Maximum operating pressure1.0 MPa
Minimum operating pressure0.12 MPa0.1 MPa
Ambient temperature and working fluid temperature-10°C to 60°C (no freezing)
Piston speedNote)50 to 500 mm/s50 to 400 mm/s
CushioningRubber bumper at both ends
LubricationNot required (non-lube)
Stroke length tolerance0 to +1.5 mm

Maximum speed with no load. Depending on the operating conditions, the piston speed may not be satisfied.

Standard stroke

Symbol Rubber bumper

Symbol Rubber bumper

Tube Internal Diameter (mm)Standard stroke (mm)
12, 1610, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250
20, 2520, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400
32 to 10025, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400

Theoretical Output List

OUT/IN

OUT/IN

Tube I.D.
(mm)
Rod size
(mm)
Operating DirectionPiston area
(mm2)
Operating pressure (MPa)
0.20.30.40.50.60.70.80.91.0
126OUT11323344557687990102113
IN85172534425159687685
168OUT201406080101121141161181201
IN1513045607590106121136151
2010OUT3146394126157188220251283314
IN236477194118141165188212236
2510OUT49198147196245295344393442491
IN41282124165206247289330371412
3214OUT804161241322402483563643724804
IN650130195260325390455520585650
4014OUT1,2572513775036287548801,0051,1311,257
IN1,1032213314415516627728829921,103
5018OUT1,9633935897859821,1781,3741,5711,7671,963
IN1,7093425136848551,0251,1961,3671,5381,709
6318OUT3,1176239351,2471,5591,8702,1822,4942,8063,117
IN2,8635738591,1451,4311,7182,0042,2902,5762,863
8022OUT5,0271,0051,5082,0112,5133,0163,5194,0214,5245,027
IN4,6469291,3941,8592,3232,7883,2523,7174,1824,646
10026OUT7,8541,5712,3563,1423,9274,7125,4986,2837,0697,854
IN7,3231,4652,1972,9293,6624,3945,1265,8586,5917,323

 

(Unit: N)

 

Theoretical output (N) = Pressure (MPa) × Piston area (mm2)

Part Number
Part NumberMinimum order quantityVolume DiscountDays to ShipCylinder (Tube) Inner Diameter
(Ø)
Stroke
(mm)
Additional Function Operating Temperature
(°C)
Operating Pressure
(MPa)
Cushion Port thread type Auto Switches Lead Wire The number of the switches Type of Shaft Bearing Option

Loading...

Basic Information

Cylinder Operation Method Double Acting Rod Operation Method Single Rods Main Body Shape Guided