(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Kindly be informed that it will be peak period in conjunction with the Chinese New Year festive season. Delivery pickup upon 25 January 2025 estimated would arrive after CNY holidays. Please expect slight delay for orders shipped during this peak season and we thank you for your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Thermo-Chiller Standard Type Single-Phase 200 to 230 V AC HRS Series (Part Numbers)

Thermo-Chiller Standard Type Single-Phase 200 to 230 V AC HRS Series

[Features]
· With a high temperature stability of ±0.1°C due to a precise temperature control method that uses an expansion valve and a temperature sensor.
· With a compact tank.
· Power supply: Single-phase 200 to 230 V AC.
· Set temperature range: 5 to 40°C.
· HRS-0□□-A: Air-cooled refrigeration type.
· HRS-0□□-W: Water-cooled refrigeration type.

(i)Caution

  • Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.
  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Thermo-Chiller Standard Type Single-Phase 200 to 230 V AC HRS Series Specifications

Air-Cooled Refrigeration Type External Appearance / Specifications

HRS Series Air-Cooled Refrigeration Type external appearance

HRS Series Air-Cooled Refrigeration Type external appearance

ModelHRS012-A□-20HRS018-A□-20HRS024-A□-20HRS030-A□-20HRS050-A□-20HRS060-A□-20
Cooling MethodAir-cooled refrigeration type
RefrigerantR407C (HFC)R410A (HFC)
Refrigerant Charge (kg)0.350.360.360.570.650.85
Control MethodPID control
Ambient Operating Temperature / Humidity / Altitude*1 *12Temperature: 5 to 40°C, High-temperature environment specification (optional): 5 to 45°C, Humidity: 30 to 70%, Altitude: less than 3,000 m
Circulating Fluid SystemCirculating Fluid*2Clear water, 15% ethylene glycol aqueous solution*4
Set Temperature Range*1 (°C)5 to 40
Cooling Capacity*3 (50/60 Hz) (W)1,100/1,3001,700/1,9002,100/2,4002,600/3,2004,700/5,1004,900/5,900
Heating Capacity*3 (50/60 Hz) (W)530/650600/6401,100/1,4001,000/1,300
Temperature Stability*5 (°C)±0.1
PumpRated Flow Rate*6 *7 (50/60 Hz) (L/min)7 (0.13 MPa) / 7 (0.18 MPa)23 (0.24 MPa) / 28 (0.32 MPa)23 (0.21 MPa) / 28 (0.29 MPa)
Maximum Flow Rate (50/60 Hz) (L/min)27/2934/4031/4229/38
Maximum Pump Head (50/60 Hz) (m)14/1950
Output (W)200550
Tank Capacity (L)Approx. 5
Pipe Connection Port DiameterRc 1/2
Fluid Contacting Parts MaterialStainless steel, copper (heat exchanger brazing), bronze, alumina ceramic, carbon, PP, PE, POM, FKM, EPDM, PVC
Electrical SystemsPower SupplySingle-phase 200 to 230 V AC (50/60 Hz)
Allowable voltage variation ±10%
Circuit Protector (A)102030
Compatible Earth Leakage Circuit Breaker Capacity*8 (A)102030
Rated Operating Current (A)4.6/5.14.7/5.25.1/5.95.2/6.08/118.9/11.5
Rated Power Consumption*3 (50/60 Hz) (kVA)0.9/1.00.9/1.01.0/1.21.0/1.21.7/2.21.8/2.3
Noise Level*9 (50/60 Hz) (dB)60/6162/6565/6866/68
AccessoriesPipe fitting (for drain outlet) 1 pc.*11, Input/output signal connector 1 pc., Power supply connector 1 pc.*11
Operation manual (for installation and operation) 1 pc., Quick manual (with a clear case) 1 pc.*11
Alarm code list sticker 1 pc., ferrite core (for communication) 1 pc.
Power cable must be purchased separately or provided by the user.
Weight*10 (kg)43476973

*Some values differ from the standard specifications due to optional features. See the catalog for details.

*1: Use in a condensation-free environment.
*2: If you are using clear water, please use water that meets the Japan Refrigeration and Air Conditioning Industry Association Water Quality Standards (JRA GL-02-1994: Cooling Water / Circulation Type / Supply Water).
*3: Values when: 1. Ambient operating temperature: 25°C, 2. Circulating fluid temperature: 20°C, 3. Rated flow rate of circulating fluid, 4. Circulating fluid: clear water. See the cooling capacity graphs in the catalog for details.
*4: If the circulating fluid temperature is below 10°C, use 15% ethylene glycol aqueous solution.
*5: Outlet temperature when the circulating fluid is at rated flow rate, and the outlet and return port are connected. When the installation environment and power supply are within the specification range and stable.
*6: The capacity at the outlet of this device when the circulating fluid temperature is 20°C.
*7: Minimum flow rate required to maintain cooling capacity, temperature stability, etc. Below the rated flow rate, the cooling capacity and temperature stability may not meet specifications. (In that case, use a bypass piping set [sold separately].
*8: To be provided by the customer. Use an earth leakage circuit breaker with a current sensitivity of 30 mA. (An option with an earth leakage circuit breaker [symbol B] is also available.)
*9: When front 1 m, height 1 m, stable with no load. See *3 for other conditions.
*10: Weight in a dry state without circulating fluid.
*11: Not included with the HRS050/060.
*12: For altitudes above 1,000 m, please refer to "*For altitudes above 1,000 m" in Section 14 "Operating Environment and Storage Environment," on p. 64 of the catalog.

Water-Cooled Refrigeration Type External Appearance / Specifications

HRS Series Water-Cooled Refrigeration Type external appearance

HRS Series Water-Cooled Refrigeration Type external appearance

ModelHRS012-W□-20HRS018-W□-20HRS024-W□-20HRS030-W□-20HRS050-W□-20HRS060-W□-20
Cooling MethodWater-cooled refrigeration type
RefrigerantR407C (HFC)R410A (HFC)
Refrigerant Charge (kg)0.30.310.310.50.650.75
Control MethodPID control
Ambient Operating Temperature / Humidity / Altitude*1Temperature: 5 to 40°C, Humidity: 30 to 70%, Altitude: Less than 3,000 m
Circulating Fluid SystemCirculating Fluid*2Clear water, 15% ethylene glycol aqueous solution*4
Set Temperature Range*1 (°C)5 to 40
Cooling Capacity*3 (50/60 Hz) (W)1,100/1,3001,700/1,9002,100/2,4002,600/3,2004,700/5,1004,900/5,900
Heating Capacity*3 (50/60 Hz) (W)530/650400/6001,000/1,300
Temperature Stability*5 (°C)±0.1
PumpRated Flow Rate*6 *7 (50/60 Hz) (L/min)7 (0.13 MPa) / 7 (0.18 MPa)23 (0.24 MPa) / 28 (0.32 MPa)23 (0.21 MPa) / 28 (0.29 MPa)
Maximum Flow Rate (50/60 Hz) (L/min)27/2934/4031/4229/38
Maximum Pump Head (50/60 Hz) (m)14/1950
Output (W)200550
Tank Capacity (L)Approx. 5
Pipe Connection Port DiameterRc 1/2
Fluid Contacting Parts MaterialStainless steel, copper (heat exchanger brazing), bronze, alumina ceramic, carbon, PP, PE, POM, FKM, EPDM, PVC
Heat-Dissipating Water SystemTemperature Range (°C)5 to 40
Pressure Range (MPa)0.3 to 0.5
Required Flow Rate*11 (50/60 Hz) (L/min)81214151617
Inlet-Outlet Pressure Differential of Heat-Dissipating Water (MPa)0.3 or more
Pipe Connection Port DiameterRc3/8Rc 1/2
Fluid Contacting Parts MaterialStainless steel, copper (heat exchanger brazing), bronze, synthetic rubber
Electrical SystemsPower SupplySingle-phase 200 to 230 V AC (50/60 Hz)
Allowable voltage variation ±10%
Circuit Protector (A)1020
Compatible Earth Leakage Circuit Breaker Capacity*8 (A)1020
Rated Operating Current (A)4.6/5.14.7/5.25.1/5.95.2/6.07.6/107.6/10.4
Rated Power Consumption Note 3) (50/60 Hz) kVA0.9/1.00.9/1.01.0/1.21.0/1.21.5/2.01.5/2.1
Noise Level*9 (50/60 Hz) (dB)60/6162/6565/6866/68
AccessoriesPipe fitting (for drain outlet) 1 pc.*12, Input/output signal connector 1 pc., Power supply connector 1 pc.*12
Operation manual (for installation and operation) 1 pc., Quick manual (with a clear case) 1 pc.*12
Alarm code list sticker 1 pc., ferrite core (for communication) 1 pc.
Power cable must be purchased separately or provided by the user.
Weight*10 (kg)434667

*Some values differ from the standard specifications due to optional features. See the catalog for details.

*1: Use in a condensation-free environment.
*2: If you are using clear water, please use water that meets the Japan Refrigeration and Air Conditioning Industry Association Water Quality Standards (JRA GL-02-1994: Cooling Water / Circulation Type / Supply Water).
*3: Values when: 1. Ambient operating temperature: 25°C, 2. Circulating fluid temperature: 20°C, 3. Rated flow rate of circulating fluid, 4. Circulating fluid: clear water, 5. Heat-dissipating water temperature: 25°C. See the cooling capacity graphs in the catalog for details.
*4: If the circulating fluid temperature is below 10°C, use 15% ethylene glycol aqueous solution.
*5: Outlet temperature when the circulating fluid is at rated flow rate, and the outlet and return port are connected. When the installation environment and power supply are within the specification range and stable.
*6: The capacity at the outlet of this device when the circulating fluid temperature is 20°C.
*7: Minimum flow rate required to maintain cooling capacity, temperature stability, etc.
Below the rated flow rate, the cooling capacity and temperature stability may not meet specifications. (In that case, use a bypass piping set [sold separately].)
*8: To be provided by the customer. Use an earth leakage circuit breaker with a current sensitivity of 30 mA. (An option with an earth leakage circuit breaker [symbol B] is also available.)
*9: When front 1 m, height 1 m, stable with no load. See *3 for other conditions.
*10: Weight in a dry state without circulating fluid.
*11 Required flow rate when the circulating fluid temperature is 20°C, the circulating fluid is at the rated flow rate, the heat-dissipating fluid is 25°C and the listed cooling capacity load is applied.
*12: Not included with the HRS050/060.

Pump Capacity

HRS012/018-A/W-10 (single-phase 100/115 V AC) pump capacity

HRS012/018-A/W-10 (single-phase 100/115 V AC) pump capacity

HRS-012/018/024-A/W-20 (single-phase 200 to 230 V AC) pump capacity

HRS-012/018/024-A/W-20 (single-phase 200 to 230 V AC) pump capacity

Mechanical seal details

Mechanical seal details

Notes

*The pump used in the Thermo-Chiller HRS050/060 Series uses a mechanical seal with a fixed ring and a rotating ring in the shaft seal. If foreign matter enters the gap in the seal, it could cause issues such as seal leakage, pump lock, etc., so it is highly recommended that a particle filter is installed on the chiller return piping.

Dimensions

 

(Unit: mm)

 

HRS012/018/024 dimensions/diagram

HRS012/018/024 dimensions/diagram

  1. *1: A power supply cable is not included. (Power supply connectors are included.)
  2. *2: Conversion fitting (R 3/8 male thread) is included.
HRS030-A-20 dimensions/diagram

HRS030-A-20 dimensions/diagram

  1. *1: A power supply cable is not included. (Power supply connectors are included.)
  2. *2: Conversion fitting (R 3/8 male thread) is included.
HRS030-W-20 dimensions/diagram

HRS030-W-20 dimensions/diagram

  1. *1: A power supply cable is not included. (Power supply connectors are included.)
  2. *2: Conversion fitting (R 3/8 male thread) is included.
HRS050/060-A dimensions/diagram

HRS050/060-A dimensions/diagram

HRS050/060-W dimensions/diagram

HRS050/060-W dimensions/diagram

  • *For information other than the above, please refer to the catalog.
  • *Product pictures are representative images.
Part Number
HRS024-A-20-BGJT
HRS024-A-20-BGM
HRS024-A-20-BGMT
HRS024-A-20-BGT
HRS024-A-20-BJ
HRS024-A-20-BJM
HRS024-A-20-BJT
HRS024-A-20-BM
HRS024-A-20-BMT
HRS024-A-20-BMW
HRS024-A-20-BT
HRS024-A-20-BW
HRS024-A-20-G
HRS024-A-20-GJ
HRS024-A-20-GM
HRS024-A-20-GMT
HRS024-A-20-GT
HRS024-A-20-J
HRS024-A-20-JM
HRS024-A-20-JMT
HRS024-A-20-JT
HRS024-A-20-M
HRS024-A-20-MT
HRS024-A-20-MW
HRS024-A-20-T
HRS024-A-20-W
HRS024-AF-20
HRS024-AF-20-B
HRS024-AF-20-BGJ
HRS024-AF-20-BGJMT
HRS024-AF-20-BJ
HRS024-AF-20-BJM
HRS024-AF-20-BT
HRS024-AF-20-G
HRS024-AF-20-GJ
HRS024-AF-20-GJM
HRS024-AF-20-GT
HRS024-AF-20-J
HRS024-AF-20-JMT
HRS024-AF-20-JT
HRS024-AF-20-M
HRS024-AF-20-MT
HRS024-AF-20-T
HRS024-AF-20-W
HRS024-AN-20
HRS024-AN-20-B
HRS024-AN-20-BG
HRS024-AN-20-BJW
HRS024-AN-20-BT
HRS024-AN-20-GT
HRS024-AN-20-J
HRS024-AN-20-JMT
HRS024-AN-20-M
HRS024-AN-20-MT
HRS024-AN-20-T
HRS024-AN-20-TW
HRS024-W-20
HRS024-W-20-B
HRS024-W-20-BJ
HRS024-W-20-BJMT
HRS024-W-20-BM
HRS024-W-20-BMT
HRS024-W-20-BT
HRS024-W-20-J
HRS024-W-20-JM
HRS024-W-20-JMT
HRS024-W-20-JT
HRS024-W-20-M
HRS024-W-20-MT
HRS024-W-20-T
HRS024-WF-20
HRS024-WF-20-B
HRS024-WF-20-BJ
HRS024-WF-20-J
HRS024-WF-20-M
HRS024-WF-20-MT
HRS024-WF-20-T
HRS024-WN-20
HRS024-WN-20-BJ
HRS024-WN-20-BM
HRS024-WN-20-BT
HRS024-WN-20-JT
HRS024-WN-20-M
HRS024-WN-20-MT
HRS024-WN-20-T
HRS030-A-20
HRS030-A-20-B
HRS030-A-20-BJ
HRS030-A-20-BJM
HRS030-A-20-BJT
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Cooling Method Cooling capacity Piping thread type Optional specifications Cooling method Power Supply Specification

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / High-temperature environment specification / With automatic water supply / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / High-temperature environment specification / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / High-temperature environment specification / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / High-temperature environment specification / High pump head specifications--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)RcWith earth leakage circuit breaker / for deionized water (pure water) piping / SI unit onlyAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

MYR 47,521.85

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / High pump head specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)RcWith earth leakage circuit breaker / SI unit onlyAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

MYR 41,618.10

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcHigh-temperature environment specification--

MYR 43,808.50

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcHigh-temperature environment specification / With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcHigh-temperature environment specification / Compatible with deionized water (pure water) piping--

MYR 56,042.88

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcHigh-temperature environment specification / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcHigh temperature environmental specification / High pump head specification--

MYR 41,992.00

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcWith automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith automatic water supply / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith automatic water supply / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcAutomatic water supply / High pump head specification--

MYR 42,299.23

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcCompatible with deionized water (pure water) piping--

MYR 54,226.38

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcCompatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)RcFor deionized water (pure water) piping / SI unit onlyAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

MYR 46,640.32

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcHigh pump head specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)RcSI unit fixedAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

MYR 40,590.00

1 Piece(s) 21 Day(s) Thermo-ChillerAir-Cooling2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)None--

-

1 Piece(s) Quote Thermo-ChillerAir-Cooling2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker / High-temperature environment specification / With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker / High-temperature environment specification / With automatic water supply / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker / With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping--

MYR 48,470.07

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)High-temperature environment specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)High-temperature environment specification / With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)High-temperature environment specification / With automatic water supply / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)High temperature environmental specification / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With automatic water supply / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)G (PT-G conversion fitting set included)Automatic water supply / High pump head specificationAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

-

1 Piece(s) Quote Thermo-ChillerAir-Cooling2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)Compatible with deionized water (pure water) piping--

MYR 55,175.02

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)Compatible with deionized water (pure water) piping / High pump head specification--

MYR 47,588.50

1 Piece(s) 21 Day(s) Thermo-ChillerAir-Cooling2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)High pump head specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)G (PT-G conversion fitting set included)SI unit fixedAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

MYR 40,590.00

1 Piece(s) 21 Day(s) Thermo-ChillerAir-Cooling2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)None--

MYR 41,471.10

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With earth leakage circuit breaker--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With earth leakage circuit breaker / High-temperature environment specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With earth leakage circuit breaker / with automatic water supply / SI unit onlyAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With earth leakage circuit breaker / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)High temperature environmental specification / High pump head specification--

MYR 43,341.02

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With automatic water supply / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)Compatible with deionized water (pure water) piping--

MYR 55,175.02

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)High pump head specification--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)High head pump specifications / SI unit onlyAir-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

MYR 41,671.50

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcNone--

MYR 42,553.05

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith earth leakage circuit breaker / High pump head specification--

MYR 43,861.90

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcWith automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith automatic water supply / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcWith automatic water supply / Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)RcAutomatic water supply / High pump head specification--

MYR 44,169.15

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcCompatible with deionized water (pure water) piping--

MYR 56,096.28

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcCompatible with deionized water (pure water) piping / High pump head specification--

MYR 48,510.23

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)RcHigh pump head specification--

MYR 42,740.23

1 Piece(s) 21 Day(s) Thermo-ChillerWater Cooling2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)None--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With earth leakage circuit breaker / With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)With automatic water supply--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)Compatible with deionized water (pure water) piping--

MYR 57,325.25

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)Compatible with deionized water (pure water) piping / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)G (PT-G conversion fitting set included)High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)None--

-

1 Piece(s) Quote --2100/2400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With earth leakage circuit breaker / With automatic water supplyWater-cooled refrigeration typeSingle-phase 200 to 230 V AC (50/60 Hz)

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With earth leakage circuit breaker / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)With earth leakage circuit breaker / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)Automatic water supply / High pump head specification--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)Compatible with deionized water (pure water) piping / High pump head specification--

MYR 49,738.73

1 Piece(s) 21 Day(s) --2,100/2,400 W (50/60 Hz)NPT (PT-NPT conversion fitting set included)High pump head specification--

MYR 47,548.33

1 Piece(s) 21 Day(s) Thermo-ChillerAir-Cooling2,600/3,200 W (50/60 Hz)RcNone--

MYR 48,429.88

1 Piece(s) 21 Day(s) Thermo-ChillerAir-Cooling2,600/3,200 W (50/60 Hz)RcWith earth leakage circuit breaker--

MYR 50,620.30

1 Piece(s) 21 Day(s) --2,600/3,200 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply--

-

1 Piece(s) Quote --2,600/3,200 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote --2,600/3,200 W (50/60 Hz)RcWith earth leakage circuit breaker / With automatic water supply / High pump head specification--

Loading...

Additional Products in this Category

Tech Support