(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
· A series of valves with a maximum change in volume of just 0.01 μL when opened or closed.
[Features]
· Body ported types and base mounted types.
· A compact direct operated 2/3 port solenoid valve for chemical liquids.
· Optional power-saving circuit.
· Space saving.
[Applications]
· Various types of analytic and testing devices.
Body ported type (tubing type) external appearance
Base Mounted Type (Without Sub-Plate) external appearance
Base Mounted Type (With Sub-Plate) external appearance
Model | Body Ported Type (Tubing Type) | Base Mounted Type | ||||||
---|---|---|---|---|---|---|---|---|
LVM20R1 | LVM20R2 | LVM202R | LVM20R3 | LVM20R4 | LVM205R | |||
Valve Structure | Diaphragm type direct acting poppet (rocker type) | |||||||
Valve Type | N.C. | N.O. | Universal | N.C. | N.O. | Universal | ||
Number of Ports | 2 | 3 | 2 | 3 | ||||
Fluids*1 | Air, water, deionized water (pure water), diluent, detergent | |||||||
Operating Pressure Range | -75 kPa to 0.25 MPa | -75 kPa to 0.3 MPa | ||||||
Orifice Diameter | 2 mm | |||||||
Response Time*8 | 20 ms or less (with pneumatic pressure) | |||||||
Leakage Rate | Zero for both internal and external parts (with hydraulic pressure) | |||||||
Proof Pressure*2 | 0.38 MPa | 0.45 MPa | ||||||
Ambient Operating Temperature*9 | 0 to 50°C | |||||||
Operating Fluid Temperature*9 | 0°C to 50°C (no freezing) | |||||||
Volume of Valve Chamber*3 | 84 μL | |||||||
Mounting Orientation*4 | Free | |||||||
Enclosure | IP40 equivalent | |||||||
Weight | 80 g | 80 g (without sub-plate), 94 g (with sub-plate) | ||||||
Rated Voltage | 12, 24 V DC | |||||||
Allowable Voltage Fluctuation*5 | ±10% of rated voltage | |||||||
Coil Insulation Type | Class B | |||||||
Power Consumption - Current (at 24‑V rated voltage) | Standard Type | 2.5 W (0.1 A) | ||||||
With power-saving circuit | Inrush | 4 W (0.17 A) | ||||||
Holding | 0.6 W | |||||||
Coil Switching Noise*6 | 60 dB |
*1: Select an appropriate material for the wetted parts according to the type of fluid to be used. Be sure to check the chemical resistance beforehand.
*2: Indicates pressures which do not cause breakage or cracks after a 1 minute airtight test.
*3: Indicates the volume of the clearance inside the volume chamber after the volume of the diaphragm has been subtracted.
*4: As the body (orifice shape) is designed to eliminate residual liquid, mounting in a vertical orientation with the coil facing upward is recommended. If liquid pooling is not an issue, it may be installed in any orientation.
*5: If response speed is considered critical, take adequate regulations to prevent voltage fluctuations on the negative side.
*6: This value is depending on the measurement conditions and the sound level may change depending on the measurement conditions.
*7: See the SMC catalog if the valve is to be energized continuously for extended periods of time.
*8: According to JIS B8419:2010
{Value at an ambient and fluid temperature of 25°C, at rated voltage, at the maximum operating pressure (air) and when the N.C. (IN) port is pressurized}
The response time may vary depending on the supply pressure, fluid quality, piping conditions, ambient temperature, etc.
*9: Note that when the diaphragm material is Kalrez, the valve changeover time becomes significantly longer at ambient and fluid temperatures of 15°C or less in comparison to at room temperature (roughly 25°C).
*Kv, Cv values conform to JIS B 2005:1995. C and b values conform to JIB B8390:2000.
LVM20R1 diagram
LVM20R2 diagram
LVM202R diagram
Component Parts: LVM20R1, 20R2, 202R
Number | Part Name | Material |
---|---|---|
1 | Plate | PEEK |
2 | Diaphragm Assembly | EPDM, FKM, Kalrez |
3 | Body | PBT |
4 | Slide Bushing Assembly | PPS, SUS |
5 | Armature Assembly | - |
6 | Coil Assembly | - |
7 | Sleeve | SUY |
8 | Board assembly | - |
9 | Casing | PBT |
10 | Plug | NBR |
11 | O-Ring | NBR |
(Units: mm)
LVM20R1-□□-□ (N.C.) / LVM20R2-□□-□ (N.O.) / LVM202R-□□-□ (Universal) dimensional drawing
LVM20R3-□□-□ (N.C.) / LVM20R4-□□-□ (N.O.) / LVM205R-□□-□ (Universal) dimensional drawing
Interface Recommended Dimensions
LVM20R3-□□-□ (N.C.) / LVM20R4-□□-□ (N.O.) / LVM205R-□□-□ (Universal) image of recommended interface dimensions
*Surface roughness for LVM20R3 and LVM205R is Rz3.2 or less / Surface roughness for LVM20R4 is Rz3.2 or less
LVM20R3-□□□-□ (N.C.) / LVM20R4-□□□-□ (N.O.) / LVM205R-□□□-□ (universal) dimensional drawing
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Switching Type | Connection Type | Plumbing Thread Nominal | Tube Dia. | Orifice Dia. (Ø) | Pipe opening type (details) | Voltage | Power consumption (W) | Lead wire length (mm) | Liquid-contacting parts material | Functions | Subplate specifications | CE compliant | Number of ports |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | Normally Closed | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | 2.5 | 600 | Plate: PEEK, Diaphragm: EPDM | Standard Type | Material: PVDF / Diameter: Rc 1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: EPDM | Standard Type | Material: PVDF / Diameter: Rc 1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | NPT | 1/8 | - | - | Base Mounted Type | - | 2.5 | 600 | Plate: PEEK, Diaphragm: EPDM | Standard Type | Material: PVDF / Diameter: NPT 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | 2.5 | 600 | Plate: PEEK, Diaphragm: FKM | Standard Type | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: Rc 1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | G | 1/8 | - | - | Base Mounted Type | - | 2.5 | 600 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF, Port size: G1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | G | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF, Port size: G1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | G | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF, Port size: G1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | NPT | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: NPT 1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | NPT | 1/8 | - | - | Base Mounted Type | - | 2.5 | 300 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: NPT 1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | G | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF, Port size: G1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | NPT | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 600 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: NPT 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | NPT | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: NPT 1/8 | CE-compliant product | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | G | 1/8 | - | - | Base Mounted Type | - | Inrush: 4 / Holding: 0.6 | 300 | Plate: PEEK, Diaphragm: EPDM | With power-saving circuit | Material: PVDF, Port size: G1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | NPT | 1/8 | - | - | Base Mounted Type | - | Inrush: 4 / Holding: 0.6 | 600 | Plate: PEEK, Diaphragm: Kalrez (R) | With power-saving circuit | Material: PVDF / Diameter: NPT 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Closed | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | 12 V DC | Inrush: 4 / Holding: 0.6 | 300 | Plate: PEEK, Diaphragm: EPDM | With power-saving circuit | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Open | NPT | 1/8 | - | - | Base Mounted Type | - | 2.5 | 300 | Plate: PEEK, Diaphragm: FKM | Standard Type | Material: PVDF / Diameter: NPT 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Open | NPT | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 600 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: NPT 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Open | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | Inrush: 4 / Holding: 0.6 | 1,000 | Plate: PEEK, Diaphragm: EPDM | With power-saving circuit | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 2 | ||
- | 1 Piece(s) | Quote | Normally Open | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | 12 V DC | Inrush: 4 / Holding: 0.6 | 300 | Plate: PEEK, Diaphragm: EPDM | With power-saving circuit | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 2 | ||
MYR 579.15 | 1 Piece(s) | 21 Day(s) | Universal | NPT | 1/8 | - | - | Base Mounted Type | - | 2.5 | 300 | Plate: PEEK, Diaphragm: EPDM | Standard Type | Material: PVDF / Diameter: NPT 1/8 | CE-compliant product | 3 | ||
- | 1 Piece(s) | Quote | Universal | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: FKM | Standard Type | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 3 | ||
- | 1 Piece(s) | Quote | Universal | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: Rc 1/8 | CE-compliant product | 3 | ||
- | 1 Piece(s) | Quote | Universal | G | 1/8 | - | - | Base Mounted Type | - | 2.5 | 300 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF, Port size: G1/8 | Not compliant with CE | 3 | ||
- | 1 Piece(s) | Quote | Universal | G | 1/8 | - | - | Base Mounted Type | - | 2.5 | 1,000 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF, Port size: G1/8 | Not compliant with CE | 3 | ||
- | 1 Piece(s) | Quote | Universal | NPT | 1/8 | - | - | Base Mounted Type | - | 2.5 | 600 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: NPT 1/8 | CE-compliant product | 3 | ||
- | 1 Piece(s) | Quote | Universal | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 1,000 | Plate: PEEK, Diaphragm: EPDM | Standard Type | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 3 | ||
- | 1 Piece(s) | Quote | Universal | G | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 300 | Plate: PEEK, Diaphragm: EPDM | Standard Type | Material: PVDF, Port size: G1/8 | CE-compliant product | 3 | ||
- | 1 Piece(s) | Quote | Universal | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 1,000 | Plate: PEEK, Diaphragm: FKM | Standard Type | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 3 | ||
- | 1 Piece(s) | Quote | Universal | NPT | 1/8 | - | - | Base Mounted Type | 12 V DC | 2.5 | 300 | Plate: PEEK, Diaphragm: Kalrez (R) | Standard Type | Material: PVDF / Diameter: NPT 1/8 | Not compliant with CE | 3 | ||
- | 1 Piece(s) | Quote | Universal | [Rc (R)] Rc | 1/8 | - | - | Base Mounted Type | - | Inrush: 4 / Holding: 0.6 | 600 | Plate: PEEK, Diaphragm: FKM | With power-saving circuit | Material: PVDF / Diameter: Rc 1/8 | Not compliant with CE | 3 |
Loading...
Type | Electromagnetic Type | Applicable Fluid | Air / Water / Chemical | Operating Environment | Standard |
---|---|---|---|---|---|
Driving Type | Linear Motion Type | Operating Temperature Range(°C) | 0::50 | Body Material | Resin |
Insulation Class | B |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy