(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Vacuum regulator with built-in one-touch tube fittings.
[Features]
· Stepless control of air pressure proportional to an electrical signal.
· ITV1000, 2000 and 3000 Series are compatible with various input specifications including serial communications.
· Compact and lightweight (integrated communications).
· Straight and right angle types available.
· With error indication LED.
· Flat bracket and L-bracket types available.
Part Number
Configured Part Number is shown.
ITV0090-2BS
Compact Vacuum Regulator ITV009□ Series external appearance
Model | ITV009□ | ||
---|---|---|---|
Minimum Supply Pressure | Set pressure -1 kPa | ||
Maximum Supply Pressure | -101 kPa | ||
Set Pressure Range | -1 to -100 kPa | ||
Power Supply | Voltage | 24 V DC ±10%, 12 to 15 V DC | |
Current Consumption | Power supply voltage 24 V DC type: 0.12 A or less Power supply voltage 12 to 15 V DC type: 0.18 A or less | ||
Input Signal | Voltage Type | 0 to 5 V DC, 0 to 10 V DC | |
Current Type | 4 to 20 mA DC, 0 to 20 mA DC (sink type) | ||
Input Impedance | Voltage Type | Approx. 10 k Ω | |
Current Type | Approx. 250 Ω | ||
Output Signal Note 4: | Analog Output | 1 to 5 V DC (output impedance: approx. 1 kΩ) Output accuracy ±6% F.S. or less | |
Linearity | ±1% F.S. or less | ||
Hysteresis | 0.5% F.S. or less | ||
Repeatability | ±0.5% F.S. or less | ||
Sensitivity | 0.2% F.S. or less | ||
Temperature Characteristics | ±0.12% F.S. / °C or less | ||
Operating Temperature Range | 0 to 50°C (no condensation) | ||
Enclosure | IP65 equivalent * | ||
Connection Type | Built-in one-touch fittings | ||
Connection Size | For Single Unit | Metric Size | [1], [2], [3]: ø4 mm |
Inch Size | [1], [2], [3]: ø5/32" | ||
Manifold | Metric Size | [1], [3]: ø6 mm, [2]: ø4 mm | |
Inch Size | [1], [3]: ø1/4", [2]: ø5/32" | ||
Weight Note 1: | 100 g or less (without options) |
Note 1: Indicates the weight of a single unit.
For IITV00-n,
Total weight (g) ≤ number of stations (n) × 100 + 130 (weight of end block A and B assemblies) + DIN rail weight (g).
Note 2: When there is a downstream flow consumption, the pressure may become unstable depending on the tubing conditions.
Note 3: While the power is on, the solenoid valve may make noise when operating. This noise is normal and does not indicate a fault.
Note 4: When measuring ITV analog output from 1 to 5 V DC, if the load impedance is less than 100 kΩ, the analog monitor output accuracy of ±6% F.S. or less may not be achievable. If an accuracy within ±6% is required, contact the manufacturer for further assistance. Output pressure remains unaffected.
*When using under conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use.
(Refer to the manufacturer's catalog for details.)
When the input signal rises, the vacuum pressure solenoid valve (1) turns ON. Due to this, part of the vacuum pressure (VAC.) supply passes through the vacuum pressure solenoid valve (1) and becomes vacuum pressure. This vacuum pressure feeds back to the control circuit (4) via the pressure sensor (3). Here, pressure corrections continue through alternate operation of the vacuum pressure solenoid valve and atmospheric pressure solenoid valve until the vacuum pressure becomes proportional to the input signal, thus supplying vacuum pressure that is consistently proportional to the input signal.
Operating principle drawing
Block diagram
(Unit: mm)
Single unit dimensional drawing 1
Single unit dimensional drawing 2
Single unit dimensional drawing 3
Single unit dimensional drawing 4
Port Positions
No. | [1] | [2] | [3] |
---|---|---|---|
ITV009□ | VAC | OUT | ATM |
Note: When using under conditions equivalent to IP65, connect the fitting or tube to the breathing hole prior to use. (Refer to the manufacturer's catalog for details.)
Single unit for manifold dimensional drawing
Linearity and hysteresis graph
Repeatability graph (at 50% of signal input)
Part Number |
---|
ITV0090-2BS |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Supply Side, Connecting Tube Diameter | Control Side, Connecting Tube Diameter | Input Signal | Piping specifications | Cable connector | Bracket | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,757.35 | 1 Piece(s) | 21 Day(s) | Ø4 | Ø4 | DC 0-5V | For Single Unit | Straight type 3 m | Flat-bracket | 24 V DC |
Loading...
Type | Electronic Electropneumatic Regulator | Control Method | Internal Pilot | Shape | Standard |
---|---|---|---|---|---|
Supply Side, Connection Type | One-Touch Plumbing | Control Side, Connection Type | One-Touch Plumbing | Set Pressure Range(kPa) | -1::-100 |
Please check the type/dimensions/specifications of the part ITV0090-2BS in the Compact Vacuum Regulator ITV0090/0091 Series series.
Part Number |
---|
ITV0090-0CL |
ITV0090-0CN |
ITV0090-0CS |
ITV0090-2CL |
ITV0090-2CN |
ITV0090-2CS |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Supply Side, Connecting Tube Diameter | Control Side, Connecting Tube Diameter | Input Signal | Piping specifications | Cable connector | Bracket | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,757.35 | 1 Piece(s) | 21 Day(s) | Ø4 | Ø4 | DC 4-20mA | For Single Unit | Right angle type 2 m | L-bracket | 24 V DC | ||
MYR 1,631.53 | 1 Piece(s) | 21 Day(s) | Ø4 | Ø4 | DC 4-20mA | For Single Unit | Without cable connector | L-bracket | 24 V DC | ||
MYR 1,757.35 | 1 Piece(s) | 21 Day(s) | Ø4 | Ø4 | DC 4-20mA | For Single Unit | Straight type 3 m | L-bracket | 24 V DC | ||
MYR 1,757.35 | 1 Piece(s) | 21 Day(s) | Ø4 | Ø4 | DC 0-5V | For Single Unit | Right angle type 2 m | L-bracket | 24 V DC | ||
MYR 1,631.53 | 1 Piece(s) | 21 Day(s) | Ø4 | Ø4 | DC 0-5V | For Single Unit | Without cable connector | L-bracket | 24 V DC | ||
MYR 1,757.35 | 1 Piece(s) | 21 Day(s) | Ø4 | Ø4 | DC 0-5V | For Single Unit | Straight type 3 m | L-bracket | 24 V DC |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy