(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 23/2 to 7:00 (MYT) 24/2/2025. We apologize for the inconvenience.
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series

3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series

The main valve structure is a metal seal type solenoid valve.
[Features]
・ Direct acting solenoid valve
・ Pressure can be used from 0 MPa
・ Different pressures can be supplied
・ Manifold model: VVS310, VVS311
・ Body size: 3/8 standard (VS3135), 1/2 standard (VS3145)
・ Screw type: Rc, NPT, NPTF, G
・ Option: None, manual (Locking type)

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

  • Product images may be representative. Refer to the manufacturer's catalog for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

3-Port Solenoid Valve, Direct Operated Type, VS3135/VS3145 Series, Metal Seal Specifications

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series JIS symbol

VS3135/VS3145 Series JIS symbol

FluidAir, inert gases
Operating Pressure1.5 MPa
Guaranteed Proof Pressure0 to 1.0 MPa
*1: Ambient Temperature and Operating Fluid Temperature °C-20 to 60
*2: LubricationNot required
Manual OperationNon-locking type available (manual is optional)
Electrical EntryGrommet, terminal conduit
Drip-proof terminal conduit
Coil Rated VoltageAC100, 200 V 50/60 Hz
DC24 V
Allowable Voltage Fluctuation-15% to 10% of rated voltage
Coil Insulation Type*3: Class B or equivalent (130°C)
Impact Resistance / Vibration Resistance: m/s2*4: 150/50

*1: In low temperatures, dry air is required. (no freezing)
*2: If lubricating, use turbine oil class 1 (ISO VG32).
*3: Based on JIS C 4003.
*4: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)

Model

ModelVS3135VS3145
Flow Rate Characteristics P → AA → EP → AA → E
C (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCv
1/46.10.31.56.10.41.6------
3/87.20.21.87.30.21.8------
1/29.00.22.39.00.32.4180.274.8160.344.1
3/4------200.215.1150.464.5
*1: Response Time msAC30 or less30 or less
DC60 or less80 or less
*2: Maximum Operating Frequency CPMAC300 or less180 or less
DC180 or less180 or less
Weight kgAC0.81.6
DC1.12.4
Apparent Power VAACStarting50 HZ100300
60 HZ90360
Holding50 HZ2050
60 HZ1460
Power Consumption WDC13.224

*1: Based on JIS B 8375-1981. At 0.5 MPa with no surge voltage suppressor.
*2: The minimum operating frequency is according to JIS B 8375 (once per 30 days).
*3: *1 and *2 assume controlled clean air.

Structural Drawing

VS3135/VS3145 Series structural drawing

VS3135/VS3145 Series structural drawing

NumberPart nameMaterial
1BodyDie-cast aluminum
2Solenoid CoverDie-cast aluminum
3Spool/SleeveStainless steel
4CapResin
5BushingResin
6SpringSteel wire
7Rubber Plug for CordNBR
8Round Head Combination ScrewSteel wire
9Plug for CoverNBR
10GasketNBR

11. Solenoid Coil Assembly

Electrical EntryVoltage
Grommet100 V AC
200 V AC
24 V DC
Terminal conduit100 V AC
200 V AC
24 V DC

Outline dimensional drawing

VS3135/VS3145 dimensional drawing

VS3135/VS3145 dimensional drawing

 

(Unit: mm)

 

ModelPiping Connection Port Diameter RcABCDEFGHJKLMNPøQTerminal-Related Dimensions
RSTU
VS3135-02
VS3135-03
VS3135-04
1/4, 3/8, 1/264646570113635964541932505076012096118
VS3145-04
VS3145-06
1/2, 3/4826888921181531281703536665296614096133
DC type dimensional drawing

DC type dimensional drawing

ModelPiping Connection Port Diameter RcABøC
VS3135-02
VS3135-03
VS3135-04
1/4 / 3/8 / 1/21296450.8
VS3145-04
VS3145-06
1/2, 3/41966860.5

Precautions

  • *Before use, be sure to read the safety precautions and common precautions sections in the SMC catalog.
  • *See the SMC catalog for information other than the above.
Part Number
VS3135-024
VS3135-024-N
VS3135-024P
VS3135-024T
VS3135-024T-N
VS3135-024TL
VS3135-024TL-N
VS3135-024TLP
VS3135-024TLZ
VS3135-024TP
VS3135-024TP-N
VS3135-024TZ
VS3135-024TZ-N
VS3135-024TZP
VS3135-024WTB
VS3135-024WTZ
VS3135-034
VS3135-034-N
VS3135-034P
VS3135-034P-N
VS3135-034P-T
VS3135-034T
VS3135-034T-N
VS3135-034TL
VS3135-034TL-N
VS3135-034TLP
VS3135-034TLP-F
VS3135-034TLZ
VS3135-034TLZP
VS3135-034TP
VS3135-034TP-N
VS3135-034TZ
VS3135-034TZP
VS3135-034WTB
VS3135-034WTBP
VS3135-034WTBP-N
VS3135-034WTLZ
VS3135-044
VS3135-044-F
VS3135-044-N
VS3135-044-T
VS3135-044P
VS3135-044P-N
VS3135-044P-T
VS3135-044T
VS3135-044T-N
VS3135-044T-T
VS3135-044TL
VS3135-044TL-N
VS3135-044TLP
VS3135-044TLP-F
VS3135-044TLP-N
VS3135-044TLZ
VS3135-044TLZP
VS3135-044TP
VS3135-044TZ
VS3135-044TZP
VS3135-044WT
VS3135-044WTB
VS3135-044WTBLZ
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSpecifications Voltage Pipe Port Type Plumbing Thread Nominal CV Value Lead wire electrical entry Indicator light / Surge voltage suppressor Option Body size

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT1/41.5Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Lubrication FreeAC220VNPT1/41.5Terminal conduitWith surge voltage suppressor (With AXT307-1-□)None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/41.5Dripproof conduit terminal with surge voltage suppressor (With AXT307-1-□)-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Grommet-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPT3/81.8Grommet-None3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT3/81.8Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPTF3/81.8Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Terminal conduit-None3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPT3/81.8Terminal conduit-None3/8 standard

MYR 1,139.35

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VG3/81.8Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

MYR 1,089.90

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Terminal conduit-Manual (lock type)3/8 standard

MYR 1,089.90

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPT3/81.8Terminal conduit-Manual (lock type)3/8 standard

MYR 1,065.18

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

MYR 1,296.50

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Drip-Proof / Lubrication FreeAC220VNPT3/81.8Drip-proof conduit terminal (through hole metallic fittings used)NoneManual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VG1/22.3Grommet-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPT1/22.3Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPTF1/22.3Grommet-None3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Grommet-Manual (lock type)3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPT1/22.3Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPTF1/22.3Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Terminal conduit-None3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPT1/22.3Terminal conduit-None3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPTF1/22.3Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT1/22.3Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VG1/22.3Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220VNPT1/22.3Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

MYR 1,166.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Drip-proof terminal conduit-None3/8 standard

MYR 1,235.15

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC220V[Rc (R)] Rc1/22.3Drip-proof conduit terminal (through hole metallic fittings used), with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

Loading...

Basic Information

Type Solenoid Valves Application Single Use Number of Ports 3-Port Valve
Mounting Orientation Direct Number of Solenoids Single Switching Type 2-Position Normally Closed
Status at Power Off Self-Recovery (Spring Return) Plumbing Direct Plumbing Driving Type Linear Motion Spool
Seal Type Standard Pressure Rating(MPa) 0 to 1.0

Additional Products in this Category

Tech Support