3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series

3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series

The main valve structure is a metal seal type solenoid valve.
[Features]
・ Direct acting solenoid valve
・ Pressure can be used from 0 MPa
・ Different pressures can be supplied
・ Manifold model: VVS310, VVS311
・ Body size: 3/8 standard (VS3135), 1/2 standard (VS3145)
・ Screw type: Rc, NPT, NPTF, G
・ Option: None, manual (Locking type)

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

  • Product images may be representative. Refer to the manufacturer's catalog for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

3-Port Solenoid Valve, Direct Operated Type, VS3135/VS3145 Series, Metal Seal Specifications

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series JIS symbol

VS3135/VS3145 Series JIS symbol

FluidAir, inert gases
Operating Pressure1.5 MPa
Guaranteed Proof Pressure0 to 1.0 MPa
*1: Ambient Temperature and Operating Fluid Temperature °C-20 to 60
*2: LubricationNot required
Manual OperationNon-locking type available (manual is optional)
Electrical EntryGrommet, terminal conduit
Drip-proof terminal conduit
Coil Rated VoltageAC100, 200 V 50/60 Hz
DC24 V
Allowable Voltage Fluctuation-15% to 10% of rated voltage
Coil Insulation Type*3: Class B or equivalent (130°C)
Impact Resistance / Vibration Resistance: m/s2*4: 150/50

*1: In low temperatures, dry air is required. (no freezing)
*2: If lubricating, use turbine oil class 1 (ISO VG32).
*3: Based on JIS C 4003.
*4: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)

Model

ModelVS3135VS3145
Flow Rate Characteristics P → AA → EP → AA → E
C (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCv
1/46.10.31.56.10.41.6------
3/87.20.21.87.30.21.8------
1/29.00.22.39.00.32.4180.274.8160.344.1
3/4------200.215.1150.464.5
*1: Response Time msAC30 or less30 or less
DC60 or less80 or less
*2: Maximum Operating Frequency CPMAC300 or less180 or less
DC180 or less180 or less
Weight kgAC0.81.6
DC1.12.4
Apparent Power VAACStarting50 HZ100300
60 HZ90360
Holding50 HZ2050
60 HZ1460
Power Consumption WDC13.224

*1: Based on JIS B 8375-1981. At 0.5 MPa with no surge voltage suppressor.
*2: The minimum operating frequency is according to JIS B 8375 (once per 30 days).
*3: *1 and *2 assume controlled clean air.

Structural Drawing

VS3135/VS3145 Series structural drawing

VS3135/VS3145 Series structural drawing

NumberPart nameMaterial
1BodyDie-cast aluminum
2Solenoid CoverDie-cast aluminum
3Spool/SleeveStainless steel
4CapResin
5BushingResin
6SpringSteel wire
7Rubber Plug for CordNBR
8Round Head Combination ScrewSteel wire
9Plug for CoverNBR
10GasketNBR

11. Solenoid Coil Assembly

Electrical EntryVoltage
Grommet100 V AC
200 V AC
24 V DC
Terminal conduit100 V AC
200 V AC
24 V DC

Outline dimensional drawing

VS3135/VS3145 dimensional drawing

VS3135/VS3145 dimensional drawing

 

(Unit: mm)

 

ModelPiping Connection Port Diameter RcABCDEFGHJKLMNPøQTerminal-Related Dimensions
RSTU
VS3135-02
VS3135-03
VS3135-04
1/4, 3/8, 1/264646570113635964541932505076012096118
VS3145-04
VS3145-06
1/2, 3/4826888921181531281703536665296614096133
DC type dimensional drawing

DC type dimensional drawing

ModelPiping Connection Port Diameter RcABøC
VS3135-02
VS3135-03
VS3135-04
1/4 / 3/8 / 1/21296450.8
VS3145-04
VS3145-06
1/2, 3/41966860.5

Precautions

  • *Before use, be sure to read the safety precautions and common precautions sections in the SMC catalog.
  • *See the SMC catalog for information other than the above.
Part Number
VS3135-021
VS3135-021-N
VS3135-021-T
VS3135-021P
VS3135-021P-N
VS3135-021T
VS3135-021TL
VS3135-021TL-N
VS3135-021TLP
VS3135-021TLZ
VS3135-021TLZP
VS3135-021TP
VS3135-021TP-N
VS3135-021TZ
VS3135-021TZP
VS3135-021WT
VS3135-021WTB
VS3135-021WTB-N
VS3135-021WTBL-N
VS3135-021WTBP
VS3135-021WTL
VS3135-021WTLP
VS3135-021WTLZ
VS3135-021WTP
VS3135-022
VS3135-022-T
VS3135-022P
VS3135-022T
VS3135-022TL
VS3135-022TLP
VS3135-022TLZ
VS3135-022TLZP
VS3135-022TP
VS3135-022TZ
VS3135-022TZP
VS3135-022WT
VS3135-022WTB
VS3135-022WTBLZP
VS3135-022WTBP
VS3135-022WTL
VS3135-022WTLZ
VS3135-022WTZ
VS3135-023
VS3135-023-N
VS3135-023-T
VS3135-023P
VS3135-023P-N
VS3135-023P-T
VS3135-023T
VS3135-023T-N
VS3135-023TL
VS3135-023TLP
VS3135-023TLP-N
VS3135-023TLZ
VS3135-023TLZ-N
VS3135-023TP
VS3135-023TP-F
VS3135-023TP-N
VS3135-023TZ
VS3135-023TZP
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSpecifications Voltage Pipe Port Type Plumbing Thread Nominal CV Value Lead wire electrical entry Indicator light / Surge voltage suppressor Option Body size

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPTF1/41.5Grommet-None3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit-None3/8 standard

MYR 1,139.35

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduitWith lamp and surge voltage suppressor (With AXT307-1-□)Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

MYR 1,126.98

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof terminal conduit-None3/8 standard

MYR 1,235.15

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT1/41.5Drip-proof conduit terminal (through hole metallic fittings used), with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Dripproof conduit terminal with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Dripproof conduit terminal with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc1/41.5Drip-proof terminal conduit-Manual (lock type)3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200VNPTF1/41.5Grommet-None3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Lubrication FreeAC200V[Rc (R)] Rc1/41.5Terminal conduitWith lamp and surge voltage suppressor (With AXT307-1-□)None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Terminal conduit-Manual (lock type)3/8 standard

MYR 1,065.18

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Drip-proof terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used), with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Dripproof conduit terminal with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc1/41.5Dripproof conduit terminal with surge voltage suppressor (With AXT307-1-□)-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Grommet-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110VNPT1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPTF1/41.5Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT1/41.5Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPTF1/41.5Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT1/41.5Terminal conduit-None3/8 standard

MYR 1,139.35

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT1/41.5Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT1/41.5Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VG1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

Loading...

Basic Information

Type Solenoid Valves Application Single Use Number of Ports 3-Port Valve
Mounting Orientation Direct Number of Solenoids Single Switching Type 2-Position Normally Closed
Status at Power Off Self-Recovery (Spring Return) Plumbing Direct Plumbing Driving Type Linear Motion Spool
Seal Type Standard Pressure Rating(MPa) 0 to 1.0