3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series (Part Numbers)

3‑Port Direct Operated Solenoid Valve - Metal Seal VS3135/3145 Series

The main valve structure is a metal seal type solenoid valve.
[Features]
・ Direct acting solenoid valve
・ Pressure can be used from 0 MPa
・ Different pressures can be supplied
・ Manifold model: VVS310, VVS311
・ Body size: 3/8 standard (VS3135), 1/2 standard (VS3145)
・ Screw type: Rc, NPT, NPTF, G
・ Option: None, manual (Locking type)

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

  • Product images may be representative. Refer to the manufacturer's catalog for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

3-Port Solenoid Valve, Direct Operated Type, VS3135/VS3145 Series, Metal Seal Specifications

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series terminal type external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series external appearance

VS3135/VS3145 Series JIS symbol

VS3135/VS3145 Series JIS symbol

FluidAir, inert gases
Operating Pressure1.5 MPa
Guaranteed Proof Pressure0 to 1.0 MPa
*1: Ambient Temperature and Operating Fluid Temperature °C-20 to 60
*2: LubricationNot required
Manual OperationNon-locking type available (manual is optional)
Electrical EntryGrommet, terminal conduit
Drip-proof terminal conduit
Coil Rated VoltageAC100, 200 V 50/60 Hz
DC24 V
Allowable Voltage Fluctuation-15% to 10% of rated voltage
Coil Insulation Type*3: Class B or equivalent (130°C)
Impact Resistance / Vibration Resistance: m/s2*4: 150/50

*1: In low temperatures, dry air is required. (no freezing)
*2: If lubricating, use turbine oil class 1 (ISO VG32).
*3: Based on JIS C 4003.
*4: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)

Model

ModelVS3135VS3145
Flow Rate Characteristics P → AA → EP → AA → E
C (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCvC (dm3 (s·bar)]bCv
1/46.10.31.56.10.41.6------
3/87.20.21.87.30.21.8------
1/29.00.22.39.00.32.4180.274.8160.344.1
3/4------200.215.1150.464.5
*1: Response Time msAC30 or less30 or less
DC60 or less80 or less
*2: Maximum Operating Frequency CPMAC300 or less180 or less
DC180 or less180 or less
Weight kgAC0.81.6
DC1.12.4
Apparent Power VAACStarting50 HZ100300
60 HZ90360
Holding50 HZ2050
60 HZ1460
Power Consumption WDC13.224

*1: Based on JIS B 8375-1981. At 0.5 MPa with no surge voltage suppressor.
*2: The minimum operating frequency is according to JIS B 8375 (once per 30 days).
*3: *1 and *2 assume controlled clean air.

Structural Drawing

VS3135/VS3145 Series structural drawing

VS3135/VS3145 Series structural drawing

NumberPart nameMaterial
1BodyDie-cast aluminum
2Solenoid CoverDie-cast aluminum
3Spool/SleeveStainless steel
4CapResin
5BushingResin
6SpringSteel wire
7Rubber Plug for CordNBR
8Round Head Combination ScrewSteel wire
9Plug for CoverNBR
10GasketNBR

11. Solenoid Coil Assembly

Electrical EntryVoltage
Grommet100 V AC
200 V AC
24 V DC
Terminal conduit100 V AC
200 V AC
24 V DC

Outline dimensional drawing

VS3135/VS3145 dimensional drawing

VS3135/VS3145 dimensional drawing

 

(Unit: mm)

 

ModelPiping Connection Port Diameter RcABCDEFGHJKLMNPøQTerminal-Related Dimensions
RSTU
VS3135-02
VS3135-03
VS3135-04
1/4, 3/8, 1/264646570113635964541932505076012096118
VS3145-04
VS3145-06
1/2, 3/4826888921181531281703536665296614096133
DC type dimensional drawing

DC type dimensional drawing

ModelPiping Connection Port Diameter RcABøC
VS3135-02
VS3135-03
VS3135-04
1/4 / 3/8 / 1/21296450.8
VS3145-04
VS3145-06
1/2, 3/41966860.5

Precautions

  • *Before use, be sure to read the safety precautions and common precautions sections in the SMC catalog.
  • *See the SMC catalog for information other than the above.
Part Number
VS3135-025TP
VS3135-025TP-F
VS3135-025TZ
VS3135-025TZP
VS3135-025WT
VS3135-025WT-N
VS3135-025WTB
VS3135-025WTB-N
VS3135-025WTBLZP
VS3135-025WTBP
VS3135-025WTLZ
VS3135-025WTLZP
VS3135-031
VS3135-031-N
VS3135-031-T
VS3135-031P
VS3135-031P-N
VS3135-031T
VS3135-031T-F
VS3135-031T-N
VS3135-031TL
VS3135-031TL-N
VS3135-031TLP
VS3135-031TLZ
VS3135-031TLZP
VS3135-031TP
VS3135-031TP-F
VS3135-031TP-N
VS3135-031TZ
VS3135-031TZ-N
VS3135-031TZP
VS3135-031WT
VS3135-031WTB
VS3135-031WTBL
VS3135-031WTBLZ
VS3135-031WTBP
VS3135-031WTBZ
VS3135-031WTL
VS3135-031WTLP
VS3135-031WTLZ
VS3135-031WTZ
VS3135-032
VS3135-032-T
VS3135-032P
VS3135-032T
VS3135-032T-N
VS3135-032TL
VS3135-032TLP
VS3135-032TLZ
VS3135-032TLZP
VS3135-032TP
VS3135-032TZ
VS3135-032TZP
VS3135-032WT
VS3135-032WTB
VS3135-032WTBLZ
VS3135-032WTBP
VS3135-032WTBP-N
VS3135-032WTL
VS3135-032WTLZ
VS3135-032WTLZP
VS3135-032WTZ
VS3135-033
VS3135-033-N
VS3135-033-T
VS3135-033P
VS3135-033P-F
VS3135-033P-N
VS3135-033P-T
VS3135-033T
VS3135-033T-N
VS3135-033T-T
VS3135-033TL
VS3135-033TL-N
VS3135-033TLP
VS3135-033TLP-N
VS3135-033TLZ
VS3135-033TP
VS3135-033TP-F
VS3135-033TP-N
VS3135-033TZ
VS3135-033TZ-F
VS3135-033TZ-N
VS3135-033TZP
VS3135-033WTB
VS3135-033WTB-T
VS3135-033WTBP
VS3135-033WTLZ
VS3135-034
VS3135-034-N
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipSpecifications Voltage Pipe Port Type Plumbing Thread Nominal CV Value Lead wire electrical entry Indicator light / Surge voltage suppressor Option Body size

-

1 Piece(s) Quote Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24VG1/41.5Terminal conduit-Manual (lock type)3/8 standard

MYR 1,796.63

1 Piece(s) 21 Day(s) Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Drip-proof terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24VNPT1/41.5Drip-proof terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24VNPT1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used), with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Drip-Proof / Lubrication FreeDC24V[Rc (R)] Rc1/41.5Drip-proof terminal conduitWith lamp and surge voltage suppressor (With AXT307-1-□)Manual (lock type)3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Grommet-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100VNPT3/81.8Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPTF3/81.8Grommet-None3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VG3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit-None3/8 standard

MYR 1,139.35

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Lubrication FreeAC100VG3/81.8Terminal conduitNoneManual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100VNPT3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

MYR 1,126.98

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Drip-Proof / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)With lightNone3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used), with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used), with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with light-Manual (lock type)3/8 standard

MYR 1,383.45

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC100V[Rc (R)] Rc3/81.8Dripproof conduit terminal with surge voltage suppressor (With AXT307-1-□)-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Grommet-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200VNPTF3/81.8Grommet-None3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200VNPT3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Drip-proof terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used), with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

MYR 1,296.50

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC200VNPT3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Dripproof conduit terminal with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Dripproof conduit terminal with indicator light/surge voltage suppressor (With AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Drip-Proof / Lubrication FreeAC200V[Rc (R)] Rc3/81.8Drip-proof terminal conduitWith surge voltage suppressor (With AXT307-1-□)None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Grommet-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110VNPT3/81.8Grommet-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110VNPTF3/81.8Grommet-None3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Grommet-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VG3/81.8Grommet-Manual (lock type)3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110VNPT3/81.8Grommet-Manual (lock type)3/8 standard

MYR 951.73

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110VNPTF3/81.8Grommet-Manual (lock type)3/8 standard

MYR 1,028.10

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPTF3/81.8Terminal conduit-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Terminal conduit, with light-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT3/81.8Terminal conduit, with light-None3/8 standard

MYR 1,142.88

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT3/81.8Terminal conduit, with light-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Conduit terminal with light / surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Terminal conduit-Manual (lock type)3/8 standard

MYR 1,089.90

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110VG3/81.8Terminal conduit-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT3/81.8Terminal conduit-Manual (lock type)3/8 standard

MYR 1,065.18

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VG3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPT3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Terminal conduit, with surge voltage suppressor (with AXT307-1-□)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

-

1 Piece(s) Quote Standard / Lubrication FreeAC110VNPTF3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-None3/8 standard

MYR 1,296.50

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Drip-proof conduit terminal (through hole metallic fittings used)-Manual (lock type)3/8 standard

-

1 Piece(s) Quote Drip-Proof / Lubrication FreeAC110V[Rc (R)] Rc3/81.8Drip-proof terminal conduitWith lamp and surge voltage suppressor (With AXT307-1-□)None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220V[Rc (R)] Rc3/81.8Grommet-None3/8 standard

MYR 890.38

1 Piece(s) 21 Day(s) Standard / Lubrication FreeAC220VNPT3/81.8Grommet-None3/8 standard

Loading...

Basic Information

Type Solenoid Valves Application Single Use Number of Ports 3-Port Valve
Mounting Orientation Direct Number of Solenoids Single Switching Type 2-Position Normally Closed
Status at Power Off Self-Recovery (Spring Return) Plumbing Direct Plumbing Driving Type Linear Motion Spool
Seal Type Standard Pressure Rating(MPa) 0 to 1.0