(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A base mounted type compact proportional control solenoid valve that can control the flow rate smoothly according to the current.
[Features]
· Repeatability: 3% or less.
· Hysteresis: 10% or less.
· Lifespan: 25 million cycles.
· Body material: Equivalent to C37 or SUS304 / Sealing material: FKM.
· The valve returns to closed position when power supply is OFF. Leakage amount when OFF is 5 cm³/min or less.
· Suitable for vacuum applications.
· Operation noise when opening/closing the valve is reduced.
· Can be mounted on manifolds.
Part Number
Configured Part Number is shown.
Compact Proportional Solenoid Valve PVQ10 Series external appearance
Compact Proportional Solenoid Valve PVQ10 Series JIS symbols
Standard specification | Valve Construction | Direct operated poppet | |
---|---|---|---|
Usable Fluids | Air | ||
Sealing material | FKM | ||
Main body material | C36 | ||
Fluid temperature | 0 to 50°C | ||
Ambient temperature*1 | 0 to 50°C | ||
Action | N.C. (Normally closed) | ||
Mounting direction | Free | ||
Port size | M5 | ||
Coil specifications | Power supply | 24 V DC | 12 V DC |
Coil current | 0 to 85 mA | 0 to 170 mA | |
Power Consumption | 0 to 2 W | ||
Coil insulation | Class B |
Characteristic specifications | Orifice diameter (mm) ø | 0.3 | 0.4 | 0.6 | 0.8 |
---|---|---|---|---|---|
Maximum operating pressure differential (MPa)*2 | 0.7 | 0.45 | 0.2 | 0.1 | |
Maximum Operating Pressure (MPa) | 1 MPa | ||||
Minimum operating pressure (MPa) (vacuum)*3 | 0 (0.1Pa.abs) | ||||
Flow rate L/min (at maximum operating pressure differential) | 0 to 5 | 0 to 6 | 0 to 5 | ||
Hysteresis (at maximum operating pressure differential) | 10% or less | ||||
Repeatability (at maximum operating pressure differential) | 3% or less | ||||
Start-up current (at maximum operating pressure differential) | 50% or less |
*1: Ambient temperature when not energized. When the valve is continuously energized at an ambient temperature of 50°C (when applying maximum current), the coil outer surface reaches approx. 90°C and the area around the coil (1 mm) reaches approx. 60°C. Ensure that these temperatures or lower are maintained.
*See the manufacturer's catalog regarding continuous energization.
*2: Maximum operating pressure differential indicates the maximum pressure differential (difference between pressure on side 1 and side 2) with the valve open or closed. If the pressure differential exceeds the maximum operating pressure differential for the orifice, the valve may leak.
*3: The operating pressure range for the vacuum specification spans from 0.1 Pa·abs up to the maximum operating pressure differential. A (2) port can be used for vacuum pressure.
PVQ10 (ø0.3 [diameter 0.3 mm]) flow rate characteristics graph
PVQ10 (ø0.4 [diameter 0.4 mm]) flow rate characteristics graph
PVQ10 (ø0.6 [diameter 0.6 mm]) flow rate characteristics graph
PVQ10 (ø0.8 [diameter 0.8 mm]) flow rate characteristics graph
*Flow rate varies depending on model differences and piping conditions. Select the model that fully satisfies the necessary flow rate based on the flow rate characteristics graphs.
PVQ10 Series structure drawing
Number | Part name | Material | Note |
---|---|---|---|
1 | Solenoid coil assembly | - | - |
2 | Fixed core | SUS | - |
3 | Return Spring | SUS | - |
4 | Armature assembly | SUS, aluminum, FKM | - |
5 | Body | C36 | - |
6 | O-ring | FKM | - |
7 | Round Head Combination Screw | Steel | M1.7 × 0.35 × 17 L, 2 pcs. |
8 | Sub-plate | C36 | Part number: PVQ10-15-M5 |
(Unit: mm)
L plug connector (PVQ13-□L-□-M5) dimensional drawings
M plug connector (PVQ13-□M-□-M5) dimensional drawings
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Application | Mounting Orientation | Voltage | Pipe Port Type | Plumbing Thread Nominal | Lead wire electrical entry | Lead wire: Yes/No | Orifice diameter (φ) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | L plug connector | With lead wire | 0.3 | ||
MYR 575.20 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC24V | M | M5 | L plug connector | With lead wire | 0.3 | ||
MYR 542.97 | 1 Piece(s) | 21 Day(s) | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | L plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | L plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | L plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | L plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | L plug connector | With lead wire | 0.8 | ||
MYR 656.85 | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | L plug connector | With lead wire | 0.8 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | L plug connector | Without lead wire | 0.3 | ||
MYR 564.60 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC24V | M | M5 | L plug connector | Without lead wire | 0.3 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | L plug connector | Without lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | L plug connector | Without lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | L plug connector | Without lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | L plug connector | Without lead wire | 0.8 | ||
MYR 564.60 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC24V | M | M5 | L plug connector | Without lead wire | 0.8 | ||
MYR 542.97 | 1 Piece(s) | 21 Day(s) | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | M plug connector | With lead wire | 0.3 | ||
MYR 575.20 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC24V | M | M5 | M plug connector | With lead wire | 0.3 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | M plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | M plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | M plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | M plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC24V | - | - | M plug connector | With lead wire | 0.8 | ||
MYR 575.20 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC24V | M | M5 | M plug connector | With lead wire | 0.8 | ||
MYR 564.60 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC24V | M | M5 | M plug connector | Without lead wire | 0.3 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | M plug connector | Without lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC24V | M | M5 | M plug connector | Without lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | L plug connector | With lead wire | 0.3 | ||
MYR 575.20 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC12V | M | M5 | L plug connector | With lead wire | 0.3 | ||
MYR 542.97 | 1 Piece(s) | 21 Day(s) | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | L plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | L plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | L plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | L plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | L plug connector | With lead wire | 0.8 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | L plug connector | With lead wire | 0.8 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | L plug connector | Without lead wire | 0.3 | ||
MYR 645.28 | 1 Piece(s) | 27 Day(s) | Single Use | Direct | DC12V | M | M5 | L plug connector | Without lead wire | 0.3 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | L plug connector | Without lead wire | 0.6 | ||
MYR 564.60 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC12V | M | M5 | L plug connector | Without lead wire | 0.8 | ||
MYR 621.75 | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | M plug connector | With lead wire | 0.3 | ||
MYR 575.20 | 1 Piece(s) | 21 Day(s) | Single Use | Direct | DC12V | M | M5 | M plug connector | With lead wire | 0.3 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | M plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | M plug connector | With lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | M plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | M plug connector | With lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | M plug connector | With lead wire | 0.8 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | M plug connector | With lead wire | 0.8 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | M plug connector | Without lead wire | 0.3 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | M plug connector | Without lead wire | 0.4 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | M plug connector | Without lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Single Use | Direct | DC12V | M | M5 | M plug connector | Without lead wire | 0.6 | ||
- | 1 Piece(s) | Quote | Unit for Manifold Mounting | Manifold Base | DC12V | - | - | M plug connector | Without lead wire | 0.8 |
Loading...
Type | Solenoid Valves | Specifications | Standard / Low Vacuum Compatible | Number of Solenoids | Single |
---|---|---|---|---|---|
Switching Type | 2-Position Normally Closed | Status at Power Off | Self-Recovery (Spring Return) | Plumbing | Sub-Base Plumbing |
Driving Type | Linear Motion Poppet | Seal Type | Soft Seal | Pressure Rating(MPa) | 0 to 1.0 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy