(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Valve unit for converter.
[Features]
· Valve unit size: small flow / large flow.
· Control valve: none, flow control valve (with pressure compensation), throttle valve, timid flow control valve (only CCVS Series).
· Combined valve: none*, stop valve + skip valve, stop valve, skip valve.
*When combined valve is "none", no solenoid valve is included.
· Electrical entry of solenoid valve: air operated, grommet, DIN terminal.
· Applicable converter: small flow, 63 mm / 100 mm, large flow, 100 mm / 160 mm.
Part Number
Configured Part Number is shown.
CCVL02-0-U2
Valve Unit CCVS/CCVL Series external appearance
Specifications | Combined valve | Control valve | ||||||
---|---|---|---|---|---|---|---|---|
Stop valve + skip valve | Throttle valve | Flow control valve | ||||||
Small flow | High flow rate shape | Small flow | High flow rate shape | Timid flow | Small flow | High flow rate shape | ||
Operating pressure | 0 to 0.7 MPa | 0 to 0.7 MPa | 0.3 to 0.7 MPa | |||||
External pilot pressure | 0.3 to 0.7 MPa | - | - | |||||
Proof pressure | 1.05 MPa | |||||||
Ambient and fluid temperature | 5 to 50°C | |||||||
Fluid | Turbine oil (40 to 100 mm2/s) | |||||||
Effective area (mm2) | Stop valve + skip valve | 40 | 88 | - | ||||
Control valve free open | - | 35 | 77 | 18 | 24 | 60 | ||
Control valve free flow | - | 30 | 80 | 23 | 30 | 80 | ||
Minimum control flow (dm3/min) | - | 0.3 | 0.04 | 0.06 | ||||
Pressure compensating ability | - | - | ±10% | |||||
Pressure compensating range | - | - | Load ratio: 60% compared to theoretical output | |||||
Valve type | N.C. | - | - |
Solenoid valve model | VO307-□□1 | ||
---|---|---|---|
External pilot pressure | 0.3 to 0.7 MPa | ||
Coil rated voltage V | AC (50/60 Hz) | 100, 200, 110, 220, 240 | |
DC | 24, 12 | ||
Apparent power*1 | AC | Inrush | 12.7 VA (50 Hz) 10.7 VA (60 Hz) |
Holding | 7.6 VA (50 Hz) 5.4 VA (60 Hz) | ||
DC | 4 W | ||
Electrical entry | Grommet (standard), DIN terminal |
*1 When rated voltage is applied
Solenoid valve style | *N.C. | **N.O. | |
---|---|---|---|
Valve type | Stop valve | Not displayed | N.O. |
Stop valve | N.O. | Not displayed |
*Valve opens when solenoid valve conducts electricity.
**Valve opens when solenoid valve stops conducting electricity.
CCVS/CCVL Series Valve Unit dimensional drawing
(Unit: mm)
Model | Oil port size Rc | A | B | *CA | *CL | F | GA | GB | GL | KA |
---|---|---|---|---|---|---|---|---|---|---|
CCVS02-□G-S | 1/2 | - | - | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
CCVS□1-□G-S | 1/2 | 121.8 | 98 | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
CCVS□2-□G-S | 1/2 | - | 98 | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
CCVS□3-□G-S | 1/2 | - | 98 | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
CCVS□0-S | 1/2 | - | 98 | 72 | 36 | - | - | 35 | - | 86 |
CCVL02-□G-S | 3/4 | - | - | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
CCVL□1-□G-S | 3/4 | 132.8 | 135 | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
CCVL□2-□G-S | 3/4 | - | 135 | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
CCVL□3-□G-S | 3/4 | - | 135 | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
CCVL□0-S | 3/4 | - | 135 | 100 | 40 | - | - | 50 | - | 116 |
Model | KB | KL | L | M | NB | NL | QA | QB | QL | R | S | T |
---|---|---|---|---|---|---|---|---|---|---|---|---|
CCVS02-□G-S | 45 | 80 | 148.5 | - | 17.5 | 25 | 103.9 | 45 | 88.2 | 1 | M5 × 0.8 | 5.4 to 7.5 |
CCVS□1-□G-S | 45 | 80 | 148.5 | 57 | 17.5 | 25 | - | - | - | 2 | ||
CCVS□2-□G-S | 45 | 80 | 148.5 | 57 | 17.5 | 25 | 103.9 | - | 88.2 | 1 | ||
CCVS□3-□G-S | 45 | 80 | 148.5 | 57 | 17.5 | 25 | 103.9 | - | 88.2 | 1 | ||
CCVS□0-S | 45 | 80 | - | 57 | 17.5 | 25 | - | - | 88.2 | - | ||
CCVL02-□G-S | 66 | 107 | 180.5 | - | 27 | 28 | 124.9 | 62 | 115 | 1 | M6 × 1 | 10.5 to 12.5 |
CCVL□1-□G-S | 66 | 107 | 180.5 | 80 | 27 | 28 | - | - | - | 2 | ||
CCVL□2-□G-S | 66 | 107 | 180.5 | 80 | 27 | 28 | 124.9 | - | 115 | 1 | ||
CCVL□3-□G-S | 66 | 107 | 180.5 | 80 | 27 | 28 | 124.9 | - | 115 | 1 | ||
CCVL□0-S | 66 | 107 | - | 80 | 27 | 28 | - | - | 115 | - |
Part Number |
---|
CCVL02-0-U2 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Converter nominal diameter (mm) | Valve unit size | Control valve | Combined valve | Solenoid valve rated voltage | Electrical entry of solenoid valve | Suffix symbol | CE compliant |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | Connector | - | High flow rate shape | None | Stop valve | Air operated valve | Air operated type | Unit for CC100 and CC160 (unit mounted to CCT100 and 160) | None |
Loading...
Please check the type/dimensions/specifications of the part CCVL02-0-U2 in the CCVS/CCVL Series Valve Unit (Large Flow / Small Flow) series.
Part Number |
---|
CCVL02-0-S |
CCVL02-1D-S |
CCVL02-1D-U2 |
CCVL02-1G-S |
CCVL02-1G-U2 |
CCVL02-2D-S |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Converter nominal diameter (mm) | Valve unit size | Control valve | Combined valve | Solenoid valve rated voltage | Electrical entry of solenoid valve | Suffix symbol | CE compliant |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | Connector | - | High flow rate shape | None | Stop valve | Air operated valve | Air operated type | Single valve | None | ||
- | 1 Piece(s) | Quote | Connector | - | High flow rate shape | None | Stop valve | 100 V AC 50/60 Hz | DIN terminal | Single valve | None | ||
- | 1 Piece(s) | Quote | Connector | - | High flow rate shape | None | Stop valve | 100 V AC 50/60 Hz | DIN terminal | Unit for CC100 and CC160 (unit mounted to CCT100 and 160) | None | ||
MYR 2,623.45 | 1 Piece(s) | 21 Day(s) | Connector | - | High flow rate shape | None | Stop valve | 100 V AC 50/60 Hz | Grommet | Single valve | None | ||
- | 1 Piece(s) | Quote | Connector | - | High flow rate shape | None | Stop valve | 100 V AC 50/60 Hz | Grommet | Unit for CC100 and CC160 (unit mounted to CCT100 and 160) | None | ||
MYR 2,730.28 | 1 Piece(s) | 21 Day(s) | Connector | - | High flow rate shape | None | Stop valve | 200 V AC 50/60 Hz | DIN terminal | Single valve | None |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy