(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Vacuum Switch Diaphragm Type ZSM1-115/121 Series (ZSM1-115L)

Vacuum Switch Diaphragm Type ZSM1-115/121 Series ZSM1-115L

Can be mounted on ejector system ZM series

(i)Caution

  • Product images may be representative images. Refer to the manufacturer's catalog for details

PDF

Part Number

Configured Part Number is shown.

ZSM1-115L

Specifications of Vacuum Pressure Switch / Diaphragm Type

External appearance of vacuum pressure switch / diaphragm type

External appearance of vacuum pressure switch / diaphragm type

Connection method of ZSM1-115

Connection method of ZSM1-115

Internal circuit of ZSM1-115

Internal circuit of ZSM1-115

  • Brown lead wire: Connect to the power supply (+) terminal is necessary to operate the switch main circuit.
  • Black lead wire: Connect to the load. (PLC input, relay)
  • Blue lead wire: Connect to the power supply GND terminal.
Internal circuit of ZSM1-121

Internal circuit of ZSM1-121

Specifications

ModelZSM1-115ZSM1-121
Switch specificationsSolid stateContact (Reed Switch)
FluidAir and inert gas
Maximum operating pressure0.5 MPa
Set pressure range-27 to -80 kPa
HysteresisMax. 15 kPaMax. 20 kPa
Repeat accuracy±10% or less
Ambient and fluid temperature-5~+60℃ (No freezing)
Supply voltageDC4.5 to 28 V100 V AC/DC or less
Indicator LightON lights
Lead number32
Port SizeR1/8
Weight65 g

Electrical Specifications

ZSM1-115

  • Supply voltage: DC4.5 to 28 V
  • Output (Open Collector): 28 V. Max 40 mA
  • Current Consumption: 10 mA or less (DC24V)

ZSM1-121

  • Supply voltage: AC/DC100V
  • Maximum operating current range: 24 V or less: 50 mA, 48 V: 40 mA, 100 V: 20 mA
  • Max. Contact Capacity: AC2VA, DC2W

Dimensions

 

(Units: mm)

 

Dimensional drawing of vacuum pressure switch / diaphragm type

Dimensional drawing of vacuum pressure switch / diaphragm type

Dimensional drawing of ZSM1-115

Dimensional drawing of ZSM1-115

Dimensional drawing of ZSM1-121

Dimensional drawing of ZSM1-121

Notes

Wiring

Contact protection box internal circuit

Contact protection box internal circuit

  1. * 1Do not apply pulling force to the power cord. It may cause damage.
  2. * 2Wiring precautions for ZSM1-121: When ZSM1-121 is connected in series, a voltage drop occurs due to the internal resistance of the light emitting diode. The voltage drop is approx. 2 V per switch. After checking the minimum drive voltage on the drive side, use within the range possible.
  3. * 3Since it does not have a built-in contact protection circuit, use the contact protection box (CD-P11) with an inductive load or a lead wire of 5 m or longer.
  4. * 4Contact protection box / connection method: To connect the switch body to the contact protection box, connect the lead wire on the side labeled SWITCH on the contact protection box and the lead wire from the switch body. Also, keep the lead wire length between the switch body and the contact protection box within 1 m, and set it as close as possible.

Mounting/Piping

The main body must not be turned with a wrench

The main body must not be turned with a wrench

  1. * 1When handling the product, always hold it by the body and do not apply pulling force to the power cord.
  2. * 2When handling, do not drop or hit. It may cause damage.
  3. * 3When mounting on the pipe, apply a wrench to the fitting and screw in. Turning the main body with a wrench may cause damage.
  4. * 4The mounting direction can be horizontal or vertical.

Pressure source

  1. * 1When used as a suction confirmation switch, do not suck in water. It may cause malfunction or damage
  2. * 2Operating fluids are dedicated for air and inert gas. Corrosive fluid cannot be used.
  • *See the SMC catalog for information other than that detailed above.
Part Number
ZSM1-115L
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPipe Port Type Plumbing Thread Type Plumbing Thread Nominal Fluid Characteristics Power Supply Type Power Supply Voltage
(V)
Lead Wire Hysteresis
(MPa)

MYR 720.42

1 Piece(s) 21 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8InertDC4.5 to 283 m0.015

Loading...

  1. 1
 

Basic Information

Type Pressure Switch Fluid Type Air / Nitrogen Gas / Carbonic Acid Gas / City Gas / Methane Gas / Propane gas Sensor, Monitor Structure Separate Type, Connector Joint
Output Method Switch Operating Temperature Range(°C) -5::60 Number of Input Points 1
Number of Output Points 1 Pipe Connection Direction Down Acquired Standards CE

Please check the type/dimensions/specifications of the part ZSM1-115L in the Vacuum Switch Diaphragm Type ZSM1-115/121 Series series.

Products like this...

Part Number
ZSM1-021
ZSM1-021L
ZSM1-115
ZSM1-121
ZSM1-121L
ZSM1-T115
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPipe Port Type Plumbing Thread Type Plumbing Thread Nominal Fluid Characteristics Power Supply Type Power Supply Voltage
(V)
Lead Wire Hysteresis
(MPa)

MYR 527.08

1 Piece(s) 21 Day(s) [Direct Mounting] ZM Ejector Mount--InertAC/DC1000.5 m0.02

MYR 580.05

1 Piece(s) 21 Day(s) [Direct Mounting] ZM Ejector Mount--InertAC/DC1003 m0.02

MYR 667.88

1 Piece(s) 21 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8InertDC4.5 to 280.5 m0.015

MYR 527.08

1 Piece(s) 21 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8InertAC/DC1000.5 m0.02

MYR 580.05

1 Piece(s) 21 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8InertAC/DC1003 m0.02

-

1 Piece(s) Quote [Threads] Male thread[NPT] NPTF[1/8] 1/8InertDC4.5 to 280.5 m0.015

Additional Products in this Category

Tech Support