(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Fan-Type Ionizer IZF10/IZF10R Series (IZF10-LP-B)

Fan-Type Ionizer IZF10/IZF10R Series IZF10-LP-B

[Features]
· Air flow adjustment function added (IZF10R).
· High-speed ionization.
· Allows you to detect emitter contamination.
· Compact fan type with simple functions.
· Alarm function for reporting high voltage issues or maintenance warnings.

(i)Caution

  • Please refer to the manufacturer's catalog for specification details.
  • The products shown in the image may be representative images only. Please refer to the manufacturer's catalog for shape details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

IZF10-LP-B

Fan-Type Ionizer, IZF10/IZF10R Series Specifications

AC Adapter (IZF10/10R-CG1, IZF10/10R-CG2)

Input Voltage100 V AC to 240 V AC, 50/60 Hz
Output Voltage24 V DC
Output Current1 A max
Ambient Operating Temperature0 to 40°C, Stored: -20 to +65℃
Ambient HumidityOperating, Stored: 10 to 90% RH (no condensation)
Standards/DirectiveCE/cUL
ModelIZF10-□□IZF10-L-□□IZF10R-□□IZF10-P-□□IZF10-LP-□□IZF10R-P-□□
Maximum Air Flow0.66 m3/min0.46 m3/min0.80 m3/min (max.)0.66 m3/min0.46 m3/min0.80 m3/min (max.)
Ion Generation MethodCorona discharge type
Voltage Application MethodDC type
Applied Voltage±5 kV
Offset Voltage (Ion Balance)*Within ±13 V
Power Supply Voltage21.6 to 26.4 V DC (Within 24 V DC ±10%)
Current Consumption220 mA or less140 mA or less270 mA or less250 mA or less170 mA or less270 mA or less
Switch outputNPN open collector output
Max. load current: 80 mA
Residual voltage: 1 V or less (load current at 80 mA)
Max. applied voltage: 26.4 V DC
NPN open collector output
Max. load current: 150 mA
Residual voltage: 1 V or less (load current at 150 mA)
Max. applied voltage: 26.4 V DC
PNP open collector output
Max. load current: 80 mA
Residual voltage: 1 V or less (load current at 80 mA)
PNP open collector output
Max. load current: 150 mA
Residual voltage: 1 V or less (load current at 150 mA)
Ambient temperatureOperating: 0 to 50°C, Stored: -10 to +60°C
Ambient humidityOperating, Stored: 35 to 80% RH (no condensation)
MaterialCase: ABS / Stainless steel, Emitter: Tungsten
Weight280 g (With bracket 360 g)260 g (With bracket 340 g)280 g (With bracket 360 g)260 g (With bracket 340 g)
Standards/DirectiveCE (EMC Directive: 2004/108/EC)CE (EMC directive: 2014/30/EU)CE (EMC Directive: 2004/108/EC)CE (EMC directive: 2014/30/EU)

*Based on ANSI/ESD-STM3.1-2006 standards

Display Function Names and Descriptions

IZF10/IZF10R Series display function names and descriptions

IZF10/IZF10R Series display function names and descriptions

No.NamePanel DisplayTypeDescription
1Power supply switch-SwitchSwitches power ON and OFF.
2Power supply indicator-LED (Green/Orange)Lights up green when power is supplied and lights up orange when incorrect high voltage or output signal over current is detected.
3Error indicatorALARMLED (Red)Lights up red when incorrect high voltage of 100 ms or more is generated.
4Maintenance indicatorNDLLED (Green)Lights up green when emitter is contaminated or worn.
5Air flow adjustment*BLOW SPEEDRotary switchAdjusts fan air flow.
6Balance adjustment-TrimmerAdjusts offset voltage (ion balance).
7Power connector-ConnectorConnects the power supply cable or AC adapter.

*IZF10R only

Alarm Details

Alarm nameOutput signal at the time of alarm*LED lightingOperation after alarm generatedDescriptionAction to reset alarm after issue resolved
Incorrect high voltageError signal OFF
(B Contact)
Power supply indicator
(Orange)
Error indicator
(Red)
StopIncorrect high voltage discharge of 100 ms or more generatedSupply power again
Output signal overcurrentOvercurrent generation signal OFFPower supply indicator
(Orange)
ContinueOvercurrent generated on output circuitAutomatic reset
Maintenance alarmMaintenance signal ON
(A-Contact)
Maintenance indicator
(Green)
ContinueStatic neutralization performance is reduced due to contamination or wear of the emittersSupply power again

*NPN/PNP open collector output

Wiring Chart / IZF10

Location of number stamped on IZF10 connector

Location of number stamped on IZF10 connector

Pin No.Signal NameDescription
1+24 V DCPower supply connection.
20 V
3F.G.Ground terminal with a ground resistance of 100Ω or less to use as a reference electric potential of offset voltage.
4Error SignalTurns OFF when a high voltage abnormality or output signal overcurrent is detected (ON during normal operation).

Dimensional Outline Drawing

 

(Unit: mm)

 

IZF10 Series dimensional drawing

IZF10 Series dimensional drawing

 

(Unit: mm)

 

IZF10R Series dimensional drawing

IZF10R Series dimensional drawing

 

(Unit: mm)

 

IZF10/IZF10R Series dimensional drawing (side view)

IZF10/IZF10R Series dimensional drawing (side view)

 

(Unit: mm)

 

IZF10/IZF10R Series dimensional drawing (back view)

IZF10/IZF10R Series dimensional drawing (back view)

 

(Unit: mm)

 

IZF10/IZF10R Series dimensional drawing (top part)

IZF10/IZF10R Series dimensional drawing (top part)

 

(Unit: mm)

 

IZF10/IZF10R Series variable angles

IZF10/IZF10R Series variable angles

 

(Unit: mm)

 

Dimensional drawing with bracket mounted

Dimensional drawing with bracket mounted

Specific Product Precautions

  • *This product is intended for use with general factory automation (FA) equipment. If considering using the product for other applications (especially those stipulated in the Safety Instructions), contact SMC beforehand.
  • *Use this product within the specified voltage and temperature range. Using outside of the specified voltage may cause malfunction, damage, electric shock or fire.
  • *This product is not an explosion-proof structure. Never use this product in locations where a dust explosion may occur or in an atmosphere where flammable or explosive gases are used. This may cause fire.
  • *Ensure that you read the "Safety Precautions" and "Specific Product Precautions" prior to use.
  • *Product images are representative images. These images may differ from the actual products.
  • *Refer to the catalog for further information.
Part Number
IZF10-LP-B
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Indicators Additional Function Air Flow/Air Consumption Quantity
(m3/min)
Ion Balance Adjusting Function Power Supply Options Accessories/options: ordered separately I/O specifications Compatible

MYR 2,654.80

1 Piece(s) 21 Day(s) Fan TypeFan Error LampError Signal Output0.46ManualDC24V-With power supply cable (3 m) / With bracketPNP output-

Loading...

  1. 1

Please check the type/dimensions/specifications of the part IZF10-LP-B in the Fan-Type Ionizer IZF10/IZF10R Series series.

Products like this...

Part Number
IZF10-B1
IZF10-CG1
IZF10-CG2
IZF10-LP-N
IZF10-LP-NB
IZF10-LP-Q
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Indicators Additional Function Air Flow/Air Consumption Quantity
(m3/min)
Ion Balance Adjusting Function Power Supply Options Accessories/options: ordered separately I/O specifications Compatible

MYR 144.80

1 Piece(s) 21 Day(s) Related Components-----Accessories (ordered separately)Bracket / without airflow adjustment function-IZF10 application

MYR 591.08

1 Piece(s) 21 Day(s) ----------

MYR 531.05

1 Piece(s) 21 Day(s) Related Components-----Accessories (ordered separately)AC adapter (without AC cord) / without airflow adjustment function-IZF10 application

-

1 Piece(s) Quote Fan TypeFan Error LampError Signal Output0.46ManualDC24V-NonePNP output-

MYR 2,401.40

1 Piece(s) 21 Day(s) Fan TypeFan Error LampError Signal Output0.46ManualDC24V-With bracketPNP output-

-

1 Piece(s) Quote Fan TypeFan Error LampError Signal Output0.46ManualDC24V-With AC adapter (with AC cord)PNP output-

Additional Products in this Category

Tech Support