Electrostatic Sensor Monitor, IZE11 Series (IZE111-LAC)

Electrostatic Sensor Monitor, IZE11 Series IZE111-LAC

RoHS-compliant electrostatic sensor monitor that can be vertically or horizontally mounted.
[Features]
· Minimum unit setting: 0.001 kV (at ±0.4 kV), 0.1 kV at ±20 kV).
· Display accuracy: ±0.5% F.S. ±1 digit or less.
· Detection distance correction function (adjustable in 1 mm increments).
· Supports two types of sensors (±0.4 kV, ±20 kV) using range selection.
· 2-color (Red/Green) display.
· Connection by connector.
· Peak/Bottom value display.
· Key lock function.

(i)Caution

  • Please refer to the manufacturer's catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

IZE111-LAC

Electrostatic Sensor Monitor, IZE11 Series Specifications

IZE11 Series external appearance

IZE11 Series external appearance

Connection by connector

Connection by connector

Sensors can be mounted so that they are in contact vertically and horizontally, reducing time and labor required for panel cutting

Sensors can be mounted so that they are in contact vertically and horizontally, reducing time and labor required for panel cutting

Product dimension: □30 mm

2-color red and green display can be set to 4 display color patterns

2-color red and green display can be set to 4 display color patterns

PatternONOFF
(1)RedGreen
(2)GreenRed
(3)RedRed
(4)GreenGreen
ModelIZE11□
Connection SensorIZD10-110IZD10-510
Rated Measurement Range-0.4 kV to +0.4 kV*1-20kV to +20kV*2
Minimum Unit Setting0.001 kV0.1 kV
Measurement Distance Setting10 to 50 mm25 to 75 mm
Power Supply Voltage21.6 to 26.4 V DC (24 V DC ±10% or less, with power supply polarity protection)
Current Consumption50 mA or less (excluding sensor unit current consumption)
Sensor Input1 to 5 V DC (Input impedance: 1 MΩ)
-Number of Inputs1 input
Input ProtectionWith excess voltage protection (up to 26.4 V)
HysteresisHysteresis mode: Variable
Window comparator mode: Variable
Switch outputNPN or PNP open collector: 2 outputs
-Max. Load Current80 mA
Max. Applied Voltage30 V DC (with NPN output)
Residual Voltage1 V or less (with load current of 80 mA)
Short Circuit ProtectionWith short circuit protection
Response Time (Including Sensor Response Time)100 ms or less
Response time with anti-chattering function: 500 ms, 1 s, 2 s or less
Analog OutputVoltage OutputOutput voltage: 1 to 5 V (in accordance with rated measurement range), Output impedance: Approx. 1 k Ω
-Accuracy (for Readings) (25°C)±1% F.S.
Current OutputOutput current: 4 to 20 mA (in accordance with rated measurement range)
Max. load impedance: 600 Ω (at 24 V DC, Min. load impedance: 50 Ω
-Accuracy (for Readings) (25°C)±1% F.S.
Response Time (Including Sensor Response Time)200 ms (without filter), 1.5 s (with filter) or less
Display Accuracy±0.5% F.S. ±1 digit
Display Method3 + 1/2 digit, 7-segment indicator, 2-color display (Red/Green) Sampling cycle: 5 times/s
Operation Indicator LightOUT1: Illuminates when output is turned ON (Green), OUT2: Illuminates when output is turned ON (Red)
Environmental ResistanceEnclosureIP40
Operating Temperature RangeOperating: 0 to 50°C, Stored: -10 to +60°C (with no freezing or condensation)
Operating Humidity RangeOperating/stored: 35 to 85% R.H. (with no condensation)
Withstand Voltage1,000 V AC for 1 min, between live parts and housing
Insulation Resistance50 MΩor more (with 500 V DC measured via megohmmeter), between live parts and housing
Vibration Resistance10 to 150 Hz at amplitudes and accelerations smaller than 1.5 mm and
98 m/s2 respectively, in X, Y and Z directions (de-energized)
Impact Resistance100 m/s2 in X, Y, Z directions 3 times each (de-energised)
Temperature Characteristics±0.5% F.S. (based on 25°C)
Connection MethodPower supply, Output connection: 5-pin connector, Sensor connection: 4-pin connector
MaterialFront case: PBT, Rear case: PBT
WeightExcluding Power Supply and Output Connection Cable30 g
StandardsCE marking, UL (CSA) compliant

*1: Rated value when the distance between the charged object and the sensor is 25 mm
*2: Rated value when the distance between the charged object and the sensor is 50 mm

Function Names and Descriptions

IZE11 Series part names

IZE11 Series part names

Dimensional Outline Drawing

 

(Unit: mm)

 

IZE11 Series dimensional drawing

IZE11 Series dimensional drawing

 

(Unit: mm)

 

Power supply / output connection cable dimensional drawing

Power supply / output connection cable dimensional drawing

Structural diagram of connector for sensor connection

Structural diagram of connector for sensor connection

Connector for sensor connection terminal names

  • PIN No. 1: DC (+)
  • PIN No. 2: N.C.
  • PIN No. 3: DC (-)
  • PIN No. 4: IN (1 to 5 V)

 

(Unit: mm)

 

Dimensional drawing with bracket

Dimensional drawing with bracket

 

(Unit: mm)

 

Dimensional drawing with panel mount adapter

Dimensional drawing with panel mount adapter

Specific Product Precautions

  • *Ensure that you read the "Safety Precautions" and "Common/Specific Product Precautions" prior to use.
  • *Product images are representative images. These images may differ from the actual products.
  • *Refer to the catalog for further information.
Part Number
IZE111-LAC
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAccessories/options: ordered separately I/O specifications Connector options

MYR 674.97

1 Piece(s) 21 Day(s) Power supply, output connection cable / bracketNPN open connector 2 outputs + analog output 4 to 20 mAWith connector sensor connection