Refrigerated Air Dryer, Refrigerant R407C (HFC) Standard Temperature Air Inlet, IDF□D Series (IDF240D-9-440V-M)

Refrigerated Air Dryer, Refrigerant R407C (HFC) Standard Temperature Air Inlet, IDF□D Series IDF240D-9-440V-M

Large refrigerated air dryer with energy-saving design.
[Features]
· Refrigerated air dryer that protects pneumatic equipment from moisture.
· Removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail.
· Voltage (IDF190D-3): Three-phase: 200 V AC (50 Hz) / 200/220 V AC (60 Hz).
· Voltage (IDF190D-9): Three-phase different voltage (built-in transformer).
· Power supply voltage: 220 V / 380 V / 400 V / 415 V / 440 V.

(i)Caution

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2/MG types, etc., are already available.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

IDF240D-9-440V-M

Refrigerated Air Dryer, Refrigerant R407C (HFC) Standard Temperature Air Inlet IDF□D Series Specifications

IDF□D Series external appearance

IDF□D Series external appearance

IDF□D Series JIS symbol

IDF□D Series JIS symbol

SpecificationsModel
Standard-temperature air inlet
IDF190DIDF240DIDF370D
Operating range*3Applicable fluidCompressed Air
Inlet air temperature (°C)5 to 50
Inlet air pressure (MPa)0.15 to 0.97
Ambient temperature (humidity) (°C)2 to 40 (Relative humidity of 85% or less)2 to 43 (Relative humidity of 85% or less)
*4Air flow capacity m3/minStandard condition
(ANR)*1
50 Hz324354
60 Hz385065
Compressor
intake condition*2
50 Hz344657
60 Hz405369
Inlet air pressure (MPa)0.7
Inlet air temperature (°C)4035
Ambient temperature (°C)32-
Outlet air pressure dew point (°C)10
Power supply voltage (frequency)*5Three-phase 200 V AC (50 Hz) / 200/220 V AC (60 Hz)Three-phase 200 V AC (50/60 Hz)
Electric specificationsPower consumption*6 (kW)
50/60 Hz
Three-phase 200 V4.96.311.6
5.97.611.6
Operating current*6 (A)
50/60 Hz
Three-phase 200 V19.526.136.5
20.126.436.5
Applicable circuit breaker capacity*7 (Sensitivity current of 30 mA) (A)50
CondenserAir-cooledWater-cooled
Air re-heater, air coolerJapanese Class-2 pressure vessel
RefrigerantR407C (HFC)
Refrigerant charge (kg)2.484.511.0
Auto drainADH4000-04ADM200-042-8
Port size*880 (3B) flange100 (4B) flange150 (6B) flange
Weight (kg)4506601,100
Coating colorBody panel: urban white
Base: black
Control panel: sky blue
Other panels (excluding base): white
Applicable compressor output (Reference)
For screw type (kW)
190240370

*1: Indicates the air flow capacity under the standard condition (ANR) (atmospheric pressure 20°C, relative humidity 65%).
*2: Indicates the air flow capacity converted by the compressor intake condition (atmospheric pressure 32°C, relative humidity 75%).
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to "Model Selection" in the manufacturer's catalog.
*5: Refer to "How to Order" in the manufacturer's catalog when selecting the power supply voltage.
*6: These are reference values under the rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*7: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
*8: JIS 10K FF is used as a flange.

Water-Cooled Condenser Specifications (IDF370D)

CondenserShell and tube type
Cooling water flow*16 m3/h
Cooling tower performance*210RT
Water flow regulatorPressure-type automatic water supply valve
Fluid port size1 1/4 union

*1: Value when cooling water inlet temperature is 32°C and with rated load
*2: Calculated at 1 RT = 4.535 kW

Motor-Type Auto Drain

IDF370D specifications

  • Operating cycle: 4 times per minute for 8 sec/min
  • Power supply: 200 V AC 50 Hz / 60 Hz
  • Power consumption: 4 W

Structure Principle Diagram (Air/Refrigerant Circuit)

High temperature humid air from the air compressor passes through the air re-heater (1) and is pre-cooled by dehumidified cool air. Then it is cooled to the specified temperature by the air cooler (2) using the evaporation heat of the refrigerant.
At this time, the oil mist and moisture generated by condensation are automatically exhausted by the auto drain (3).
The cooled and dehumidified air goes back to the air re-heater (1), and heat is exchanged with hot air that flows into the air re-heater. It is supplied as dry warm air without "sweating" in the piping system.

IDF190D/IDF240D structure principle diagram

IDF190D/IDF240D structure principle diagram

IDF370D structure principle diagram

IDF370D structure principle diagram

Dimensions

 

(Unit: mm)

 

IDF190D/IDF240D dimensional drawing

IDF190D/IDF240D dimensional drawing

 

(Unit: mm)

 

ModelInlet and outlet portABCDEFGHIJ
IDF190DJIS 10K FF 80 (3B) flange7501,5101,320375480600700800355427
IDF240DJIS 10K FF 100 (4B) flange7701,5501,640385703730700800355592

*The auto drain is enclosed in the same shipping package as the main body. The customer is required to mount the auto drain to the air dryer.

 

(Unit: mm)

 

IDF370D dimensional drawing

IDF370D dimensional drawing

Power Transformer Integrated Type

 

(Unit: mm)

 

Dimensional drawing: power transformer integrated type

Dimensional drawing: power transformer integrated type

IDF370D

  • The power transformer marked with the voltage symbol 9 is integrated into the refrigerated air dryer.

IDF190D to 240D

  • The power transformer marked with the voltage symbol 9 is built into the inside of the main unit.
  • The outside dimensions are the same as those with the voltage symbol 3.

Precautions

  • *Pictures are of representational models. Note that the actual product may differ.
  • *See the manufacturer's catalog for information other than the above.
Part Number
IDF240D-9-440V-M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMethod Air Inlet Flow
(l/min)
Outlet Open Air Pressure Dew-point
(℃)
Inlet Air Temperature
(℃)
Inlet Air Pressure
(MPa)
Supply Side, Tube Flange Nominal Control Side, Tube Flange Nominal Power Supply Voltage Air Compressor Size Auto drain Copper Tube Anti-rust Processing Short-circuit Breaker

-

1 Piece(s) Quote [Freezing Type] Refrigerating type (air-cooling specification)43,000 / 50,00010400.7[100] 100(4B)[100] 100(4B)Three-phase 440 V (built-in power transformer)240 kWWith motor-type auto drainNoneNone

Loading...

  1. 1

Basic Information

Type Dryer Shape Standard Air Inlet Flow Rate [Distinction](l/min) More than 5000
Supply Side, Connection Type Pipe flange Control Side, Connection Type Pipe flange

Please check the type/dimensions/specifications of the part IDF240D-9-440V-M in the Refrigerated Air Dryer, Refrigerant R407C (HFC) Standard Temperature Air Inlet, IDF□D Series series.

Products like this...

Part Number
IDF190D-3-CR
IDF190D-3-CW
IDF190D-3-M
IDF240D-9-440V-MR
IDF240D-9-440V-R
IDF370D-3
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMethod Air Inlet Flow
(l/min)
Outlet Open Air Pressure Dew-point
(℃)
Inlet Air Temperature
(℃)
Inlet Air Pressure
(MPa)
Supply Side, Tube Flange Nominal Control Side, Tube Flange Nominal Power Supply Voltage Air Compressor Size Auto drain Copper Tube Anti-rust Processing Short-circuit Breaker

-

1 Piece(s) Quote [Freezing Type] Refrigerating type (air-cooling specification)32,000 / 38,00010400.7[80] 80(3B)[80] 80(3B)Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz)190 kWNoneYesYes

-

1 Piece(s) Quote [Freezing Type] Refrigerating type (water-cooling specification)32,000 / 38,00010400.7[80] 80(3B)[80] 80(3B)Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz)190 kWNoneYesNone

MYR 114,956.42

1 Piece(s) 21 Day(s) [Freezing Type] Refrigerating type (air-cooling specification)32,000 / 38,00010400.7[80] 80(3B)[80] 80(3B)Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz)190 kWWith motor-type auto drainNoneNone

-

1 Piece(s) Quote [Freezing Type] Refrigerating type (air-cooling specification)50,000 / 43,00010400.7[100] 100(4B)[100] 100(4B)Three-phase 440 V (built-in power transformer)240 kWWith motor-type auto drainNoneYes

-

1 Piece(s) Quote [Freezing Type] Refrigerating type (air-cooling specification)50,000 / 43,00010400.7[100] 100(4B)[100] 100(4B)Three-phase 440 V (built-in power transformer)240 kWNoneNoneYes

MYR 272,301.23

1 Piece(s) 21 Day(s) [Freezing Type] Refrigerating type (water-cooling specification)54,000 / 65,00010350.7[150] 150(6B)[150] 150(6B)Three-phase 200 V AC (50 Hz), 200/220 V AC (60 Hz)370 kWNoneNoneNone

Additional Products in this Category

Tech Support