(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Refrigerated air dryer that protects pneumatic equipment from moisture.
[Features]
· Removes the vapor from the moist compressed air delivered by the compressor and prevents it from causing the pneumatic equipment to fail.
· Improved corrosion resistance with the use of stainless-steel heat exchanger.
· Size: 3E, 4E, 6E, 8E, 11E, 15E.
Part Number
Configured Part Number is shown.
IDFB8E-11-ART
IDFB□E Series external appearance
*The external appearance images are representative images.
JIS symbol
Specifications | Model | ||||
---|---|---|---|---|---|
Standard-temperature air inlet | |||||
IDFB3E | IDFB4E | IDFB6E | |||
Operating range*3 | Applicable fluid | Compressed Air | |||
Inlet air temperature (°F [°C]) | 41 to 122 (5 to 50) | ||||
Inlet air pressure (psi [MPa]) | 22 (0.15) to 150 (1.0) | ||||
Ambient temperature (°F [°C]) | 36 to 104 (2 to 40), Relative humidity of 85% or less | ||||
*4 | Air flow capacity SCFM*1, *2 (m3/h [ANR]) | Outlet pressure dew point 37°F (2.8°C) | 10 (17) | 15 (25) | 25 (43) |
Outlet pressure dew point 45°F (7.2°C) | 11 (19) | 16 (27) | 26 (45) | ||
Outlet pressure dew point 50°F (10°C) | 12 (20) | 17 (28) | 28 (47) | ||
Operating pressure (psi [MPa]) | 100 (0.7) | ||||
Inlet air temperature (°F [°C]) | 100 (37.8) | ||||
Ambient temperature (°F [°C]) | 100 (37.8) | ||||
Electric specifications | Power supply voltage (frequency) | Single-phase 115 V AC (Voltage fluctuation ±10%) 60 Hz | |||
Operating current*5 (A) | 2.7 | 3.0 | 3.0 | ||
Power consumption*5 (W) | 240 | 260 | 260 | ||
Applicable circuit breaker capacity*6 (A) (Sensitivity current of 30 mA) | 15 | ||||
Condenser | Forced air-cooled | ||||
Refrigerant | R134a (HFC) | ||||
Refrigerant charge (oz [g]) | 6.3 (180) | 7.0 (200) | 8.1 (230) | ||
Thread symbol and size | Symbol N | NPT3/8 female | NPT1/2 (female) | NPT3/4 (female) | |
Symbol Nil | Rc3/8 (female) With Rc conversion adapter | Rc1/2 (female) With Rc conversion adapter | Rc3/4 (female) With Rc conversion adapter | ||
Drain tube outer diameter | Symbol N | 3/8 inch | |||
Symbol Nil | 10 mm | ||||
Coating color | Urban white 1 | ||||
Weight (lbs [kg]) | 40 (18) | 55 (25) | 57 (26) | ||
Compliant standards | UL, CSA |
Specifications | Model | ||||
---|---|---|---|---|---|
Standard-temperature air inlet | |||||
IDFB8E | IDFB11E | IDFB15E | |||
Operating range*3 | Applicable fluid | Compressed Air | |||
Inlet air temperature (°F [°C]) | 41 to 122 (5 to 50) | ||||
Inlet air pressure (psi [MPa]) | 22 (0.15) to 150 (1.0) | ||||
Ambient temperature (°F [°C]) | 36 to 104 (2 to 40), Relative humidity of 85% or less | ||||
*4 | Air flow capacity SCFM*1, *2 (m3/h [ANR]) | Outlet pressure dew point 37°F (2.8°C) | 41 (70) | 59 (100) | 71 (120) |
Outlet pressure dew point 45°F (7.2°C) | 43 (74) | 62 (106) | 80 (136) | ||
Outlet pressure dew point 50°F (10°C) | 45 (77) | 65 (110) | 86 (147) | ||
Operating pressure (psi [MPa]) | 100 (0.7) | ||||
Inlet air temperature (°F [°C]) | 100 (37.8) | ||||
Ambient temperature (°F [°C]) | 100 (37.8) | ||||
Electric specifications | Power supply voltage (frequency) | Single-phase 115 V AC (Voltage fluctuation ±10%) 60 Hz | |||
Operating current*5 (A) | 3.5 | 6.5 | 7.5 | ||
Power consumption*5 (W) | 310 | 550 | 750 | ||
Applicable circuit breaker capacity*6 (A) (Sensitivity current of 30 mA) | 15 | ||||
Condenser | Forced air-cooled | ||||
Refrigerant | R134a (HFC) | ||||
Refrigerant charge (oz [g]) | 9.5 (270) | 10.2 (290) | 12.0 (340) | ||
Thread symbol and size | Symbol N | NPT3/4 (female) | NPT1 female | ||
Symbol Nil | Rc3/4 (female) With Rc conversion adapter | Rc1 (female) With Rc conversion adapter | |||
Drain tube outer diameter | Symbol N | 3/8 inch | |||
Symbol Nil | 10 mm | ||||
Coating color | Urban white 1 | ||||
Weight (lbs [kg]) | 64 (29) | 73 (33) | 110 (50) | ||
Compliant standards | UL, CSA |
*1: Indicates the air flow capacity under ANR (atmospheric pressure 68°F (20°C), relative humidity 65%).
*2: Indicates the air flow capacity for each outlet pressure dew point.
*3: The operating range does not guarantee use at rated air flow capacity.
*4: If the operating conditions differ from the rating, select the model referring to "Model Selection" in the manufacturer's catalog.
*5: These are reference values under the rated conditions and are not guaranteed. Do not use these as thermal setting values, etc.
*6: Products without option R do not come with a circuit breaker. Purchase a circuit breaker separately.
*7: When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns.
Humid, hot air coming into the air dryer is cooled down by a cooler (heat exchanger). Water condensed at this time is removed from the air by a drain separator (auto drain) and drained out automatically. Air separated from the water is heated by a re-heater (heat exchanger) to approximately ambient temperature to obtain the dried air, which goes through to the outlet side.
Structure Principle Diagram: IDFB3E (Air/Refrigerant Circuit)
Structure principle diagram: IDFB4E/IDFB6E/IDFB8E/IDFB11E/IDFB15E (air/refrigerant circuit)
(Unit: mm)
IDFB3E dimensional drawing
(Unit: mm)
Model | Piping connection port diameter | A | B | C | D | E | F | G | H | J | K | L | M | N | Q |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IDFB3E | 3/8 | 8.9 (226) | 16.1 [410] | 18.6 [473] | 2.6 [67] | 4.9 [125] | 12.0 [304] | 1.3 [33] | 2.9 [73] | 1.2 [31] | 1.4 [36] | 6.1 [154] | 0.8 [21] | 13.0 [330] | 0.6 [15] |
(Unit: mm)
IDFB4E to IDFB11E dimensional drawing
(Unit: mm)
Model | Piping connection port diameter | A | B | C | D | E | F | G | H | J | K | L | M | N | Q |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IDFB4E | 1/2 | 10.6 [270] | 17.8 [453] | 19.6 [498] | 1.2 [31] | 1.7 [42] | 11.1 [283] | 3.1 [80] | 9.1 [230] | 1.3 [32] | 0.6 [15] | 9.4 [240] | 3.1 [80] | 10.8 [275] | 0.5 [13] |
IDFB6E | 3/4 | 17.9 [455] | |||||||||||||
IDFB8E | 19.1 [485] | 22.4 [568] | 14 [355] | 11.8 [300] | |||||||||||
IDFB11E |
(Unit: mm)
IDFB15E dimensional drawing
(Unit: mm)
Model | Piping connection port diameter | A | B | C | D | E | F | G | H | J | K | L | M | N | Q |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IDFB15E | 1 | 11.8 [300] | 23.7 [603] | 22.8 [578] | 1.6 [41] | 2.1 [54] | 16.6 [396] | 3.4 [87] | 10.2 [258] | 1.7 [43] | 0.6 [15] | 10.6 [270] | 4.0 [101] | 15.0 [380] | 0.6 [16] |
*See the manufacturer's catalog for product information other than the above.
Part Number |
---|
IDFB8E-11-ART |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Air Inlet Flow (l/min) | Air Inlet Flow Rate [Distinction] (l/min) | Outlet Open Air Pressure Dew-point (℃) | Supply Side, Connection Type | Inlet Air Pressure (MPa) | Supply Side, Plumbing Thread Nominal | Control Side, Connection Type | Control Side, Plumbing Thread Nominal | Standard size | Auto drain | For Compressed Air Cooling | For medium pressure air | Short-circuit Breaker | Power Supply Terminal Block | Operation, Terminal block for abnormal signal takeout |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 1,167 / 1,233 / 1,283 | ~2000 | 2.8 ~ 10 | [Rc(R)] Rc | 0.7 | 3/4 | [Rc(R)] Rc | 3/4 | 8E | None | Yes | None | Yes | None | Yes |
Loading...
Type | Dryer | Method | Refrigerating type (air-cooling specification) | Shape | Standard |
---|---|---|---|---|---|
Inlet Air Temperature(℃) | 37.8 | Power Supply Voltage | Single-phase 115 V AC (60 Hz) |
Please check the type/dimensions/specifications of the part IDFB8E-11-ART in the Refrigerated Air Dryer, Refrigerant R134a (HFC) Standard Temperature Air Inlet, IDFB□E Series series.
Part Number |
---|
IDFB11E-11-AK |
IDFB11E-11-ART |
IDFB11E-11-AT |
IDFB11E-11-K |
IDFB8E-11-ARTV |
IDFB8E-11-KT |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Air Inlet Flow (l/min) | Air Inlet Flow Rate [Distinction] (l/min) | Outlet Open Air Pressure Dew-point (℃) | Supply Side, Connection Type | Inlet Air Pressure (MPa) | Supply Side, Plumbing Thread Nominal | Control Side, Connection Type | Control Side, Plumbing Thread Nominal | Standard size | Auto drain | For Compressed Air Cooling | For medium pressure air | Short-circuit Breaker | Power Supply Terminal Block | Operation, Terminal block for abnormal signal takeout |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 1,833 / 1,667 / 1,767 | ~2000 | 2.8 ~ 10 | [Rc(R)] Rc | 0.7 | 3/4 | [Rc(R)] Rc | 3/4 | 11E | None | Yes | For medium-pressure air (For auto drain case: metal case with level gauge) | None | None | None | ||
- | 1 Piece(s) | Quote | 1,833 / 1,667 / 1,767 | ~2000 | 2.8 ~ 10 | [Rc(R)] Rc | 0.7 | 3/4 | [Rc(R)] Rc | 3/4 | 11E | None | Yes | None | Yes | None | Yes | ||
- | 1 Piece(s) | Quote | 1,833 / 1,667 / 1,767 | ~2000 | 2.8 ~ 10 | [Rc(R)] Rc | 0.7 | 3/4 | [Rc(R)] Rc | 3/4 | 11E | None | Yes | None | None | None | Yes | ||
- | 1 Piece(s) | Quote | 1,833 / 1,667 / 1,767 | ~2000 | 2.8 ~ 10 | [Rc(R)] Rc | 0.7 | 3/4 | [Rc(R)] Rc | 3/4 | 11E | None | None | For medium-pressure air (For auto drain case: metal case with level gauge) | None | None | None | ||
- | 1 Piece(s) | Quote | 1,233 / 1,167 / 1,283 | ~2000 | 2.8 ~ 10 | [Rc(R)] Rc | 0.7 | 3/4 | [Rc(R)] Rc | 3/4 | 8E | With a timer-controlled solenoid valve type auto drain | Yes | None | Yes | None | Yes | ||
- | 1 Piece(s) | Quote | 1,233 / 1,167 / 1,283 | ~2000 | 2.8 ~ 7.2 | [Rc(R)] Rc | - | 3/4 | [Rc(R)] Rc | 3/4 | 8E | None | None | For medium-pressure air (For auto drain case: metal case with level gauge) | None | None | Yes |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy