(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Thermac Temperature Controller [E5CB] (E5CB-Q1PD AC/DC24)

Thermac Temperature Controller [E5CB] E5CB-Q1PD AC/DC24

Ideal for heater control, the best control performance at a surprisingly low price.
[Features]
・ Character height is about 16 mm for improved visibility
・ Under-neck size 60 mm
・ Narrow down the parameters and set easily
・ Sampling period 250 ms

PDF

Part Number

Configured Part Number is shown.

E5CB-Q1PD AC/DC24

Dimensional Drawing of OMRON Temperature Controllers

THERMAC Temperature Controller [E5CB] Outline drawing
  • Crimp Temperature Controllers size: M3.5
  • Terminal cover (sold separately) (Model E53-COV19)
  • USB-serial conversion cable (sold separately) (Model: E58-CIFQ2)

Specification Table of OMRON Temperature Controllers

Temperature Controllers Ratings/Performance

Rating

Power supply voltageAC100~240V 50/60Hz, AC24V 50/60Hz, DC24V
Allowable voltage fluctuation range85 to 110% of rated voltage
Power ConsumptionApprox. 3.5VA (AC100-240V)
Approx. 3.5VA (AC 24V)
Approx. 2.5W (DC24V)
Temperature Controllers Sensor TypeThermocouple: K, J, T, R, S (JIS C 1602-1995, IEC60584-1)
Platinum resistance thermometer: Pt100 (JIS C 1604-1997, IEC60751)
Temperature Controllers OutputRelay OutputAC250V 3A (resistive load) Electrical life 100,000 times Minimum applicable load 5V 10mA
Voltage output (for driving SSR)Output voltage DC12V+25%/-15% Maximum load current 21mA
Alarm OutputRelay OutputAC250V 1A (resistive load)
Temperature Controllers Method2 degrees of freedom PID or ON/OFF
Setting methodDigital setting by front keys
Instruction method7-segment digital display and single-light-emitting display
character height PV: 16.2 mm
Other featuresTemperature Controllers input correction, run/stop, protection function, etc.
Ambient temperature-10 to +55°C (but no condensation or freezing) / 3-year warranty: -10 to +50°C
Ambient humidityRelative humidity: 25-85%
Storage Temperature Controllers-25 to +65°C (but no condensation or freezing)

Temperature Controllers Performance

Indication accuracyThermocouple: *1 (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit or less
Platinum resistance thermometer: (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit or less
Temperature effect *2Thermocouple input (R, S): (±1% PV or ±10°C, whichever is greater) ±1 digit or less
Thermocouple input (K, J, T): (±1% PV or ±4°C, whichever is greater) ±1 digit or less
Platinum resistance thermometer input: (±1% PV or ±2°C, whichever is greater) ±1 digit or less
Voltage effect *2
Effects of electromagnetic interference (according to EN61326-1)
Adjustment Sensitivity0.1 to 999.9°C or °F (in 0.1°C or °F increments)
Proportional band (P)0.1 to 999.9°C or °F (in 0.1°C or °F increments)
Integration time (I)0 to 3999s (in 1s increments)
Differential time (D)0 to 3999s (in 1s increments)
Temperature Controllers Period0.5, 1 to 99 s (in 1 s increments)
Alarm Setting Range-1999 to 9999 (decimal point position depends on input type)
Input Sampling Period250ms
Effect of signal source resistanceThermocouple: 0.1℃/Ω or less (100Ω or less), Platinum resistance thermometer: 0.6℃/Ω or less (10Ω or less) *3
Insulation resistance20MΩ or more (at DC500V megger)
Withstand voltage2,300V AC, 50 or 60Hz, 1min (opposite polarity live terminals)
vibrationmalfunction10~55Hz 20m/s2 3 axis direction 10min
Durability10~55Hz 20m/s2 3 axial directions 2h
impactmalfunction200m/s23 axial directions, 3 times each
Durability300m/s23 axial directions, 3 times each
massMain unit: Approx. 100g Mounting tool: Approx. 10g
Protective structureFront: IP66, Rear case: IP20, Terminal: IP00
Memory ProtectionNon-volatile memory (number of writes: 100,000)
standardCertification StandardsUL61010-1, CSA C22.2 No.1010-1
Temperature Controllers Compliance standardsEN61326, EN61010-1, IEC61010-1, VDE0106,
Part100 (finger protection) when terminal cover is attached
EMC DirectiveEMI EN61326-1 *4Radiated
interference field strength EN55011 Group1 classANoise
terminal voltage EN55011 Group1 classAEMS
EN61326-1 *4Electrostatic
discharge immunity EN61000-4-2Electromagnetic
field immunity EN61000-4-3Burst noise immunity
EN61000-4-4Conducted
interference immunity EN61000-4-6Surge
immunity EN61000-4-5Voltage
dip/interruption immunity EN61000-4-11

*1. K and T below -100°C are within ±2°C±1 digit. R and S below 200°C are within ±3°C±1 digit.
*2. Conditions: Ambient Temperature Controllers: -10°C to 23°C to 55°C Voltage range: -15% to ±10% of rated voltage
*3. R and S sensors are 0.2°C/Ω or less (100Ω or less).
*4. Industrial electromagnetic environment (EN/IEC61326-1 Table 2)



specification of Temperature Controllers

Temperature Controllers Model numbersizePower supply voltageSensor TypeAlarm OutputTemperature Controllers Output
Temperature Controllers Model E5CB-R1TCTemperature Controllers Model E5CB
48 x 48 mm
AC100-240VThermocouples1Relay Output
Temperature Controllers Model E5CB-R1PPlatinum resistance thermometer
Temperature Controllers Model E5CB-Q1TCThermocouplesVoltage output (for driving SSR)
Temperature Controllers Model E5CB-Q1PPlatinum resistance thermometer
Temperature Controllers Model E5CB-R1TCDAC/DC24VThermocouplesRelay Output
Temperature Controllers Model E5CB-R1PDPlatinum resistance thermometer
Temperature Controllers Model E5CB-Q1TCDThermocouplesVoltage output (for driving SSR)
Temperature Controllers Model E5CB-Q1PDPlatinum resistance thermometer

Selection Support Information of OMRON Temperature Controllers

Temperature Controllers Order Example



Thermaq Temperature Controller [E5CB] Order Example
Thermaq Temperature Controller [E5CB] Order Example
Part Number
E5CB-Q1PD AC/DC24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipInput Method Output Type Power Supply Voltage
(V)
Control Output 1

MYR 455.90

1 Piece(s) 9 Day(s) or more Platinum temperature measuring resistorSSR Drive Output Voltage24 VAC/DCVoltage output (for driving SSR)

Loading...

  1. 1
 

Basic Information

Control Method ON/OFF Control / Self-tuning PID controller Number of Control Points 1 Number of Input Points(pcs.) 1
Setting Method Key input Alarm Output Relay output Specifications 48×48 mm

Please check the type/dimensions/specifications of the part E5CB-Q1PD AC/DC24 in the Thermac Temperature Controller [E5CB] series.

Products like this...

Part Number
E5CB-Q1P AC100-240
E5CB-Q1TC AC100-240
E5CB-Q1TCD AC/DC24
E5CB-R1P AC100-240
E5CB-R1PD AC/DC24
E5CB-R1TC AC100-240
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipInput Method Output Type Power Supply Voltage
(V)
Control Output 1

MYR 455.90

1 Piece(s) 5 Day(s) or more Platinum temperature measuring resistorSSR Drive Output Voltage100 to 240 VACVoltage output (for driving SSR)

MYR 457.59

1 Piece(s) 2 Day(s) ThermocoupleSSR Drive Output Voltage100 to 240 VACVoltage output (for driving SSR)

MYR 455.90

1 Piece(s) 5 Day(s) or more ThermocoupleSSR Drive Output Voltage24 VAC/DCVoltage output (for driving SSR)

MYR 457.59

1 Piece(s) 5 Day(s) or more Platinum temperature measuring resistorRelay contact100 to 240 VACRelay Output

MYR 455.90

1 Piece(s) 5 Day(s) or more Platinum temperature measuring resistorRelay contact24 VAC/DCRelay Output

MYR 457.59

1 Piece(s) 5 Day(s) or more ThermocoupleRelay contact100 to 240 VACRelay Output