(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Direct Operated 2 Port Solenoid Valve With Built-in Y Strainer VXK21/22/23 Series (Part Numbers)

Direct Operated 2 Port Solenoid Valve With Built-in Y Strainer VXK21/22/23 Series

This is a Direct Operated 2 Port Solenoid Valve With Built-in Y Strainer VXK21/22/23 Series.
[Features]
・ Space saving, reduction of piping labor hours
・ Built-in strainer
・ Removal of contaminants in fluid
・ The elements can be replaced without removing the piping

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • The product images are representative only. Please refer to the manufacturer's catalog for shape details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Drawing

Open when energized (N.C.): VXK21□0 / VXK22□0 / VXK23□0
Closed when energized (N.O.): VXK21□2 / VXK22□2 / VXK23□2

Direct acting 2-port solenoid valve with built-in Y-type strainer, VXK21/22/23 Series, Open when energized (N.C.): VXK21□0 / VXK22□0 / VXK23□0, Closed when energized (N.O.): Drawing of VXK21□2 / VXK22□2 / VXK23□2

Product Specifications

Product Specifications

Valve specificationsValve structureDirect operated poppet
Pressure resistanceMPa5.0
Body MaterialC37
Seal MaterialNBR, FKM, EPDM, PTFE
Protective structureDust-tight and water jet protection (IP65)^*)
AtmosphereLocations without corrosive or explosive gases
Strainer specificationsMesh100
MaterialsSUS
Coil SpecificationsRated VoltageAC100 V AC, 200 V AC, 110 V AC, 220 V AC, 230 V AC, 240 V AC, 48 V AC
DC24 V DC, 12 V DC
Allowable voltage fluctuation±10% of rated voltage
Allowable leak voltageAC (Type B, with built-in full-wave rectifier)10% or less of the rated voltage
AC (Type B/H)20% or less of the rated voltage
DC (Type B only)2% or less of rated voltage
Coil insulation typeClass B, class H

*) IP40 for products whose lead wire electrical entry is grommet and that is equipped with surge voltage circuit (GS)

Standard table

Standard table of direct acting 2-port solenoid valve with built-in Y-type strainer, VXK21/22/23 Series

*1) Orifice diameter ø8 is only for NC specifications.
*2) Values of (C) (E) are the dimensions of NO specifications.
*3) Dimensions of J and L of NO specifications are +1.5 mm.

Part Number
VXK2350-03-5G1
VXK2350-03-5G1-B
VXK2350-03-5GS1-B
VXK2350-03-5TL1-B
VXK2350-03-5TZ1
VXK2350-03-5TZ1-B
VXK2350-03-7D1
VXK2350-03-JDR1-B
VXK2350-03F-3DLR1-B
VXK2350-03F-4DR1
VXK2350-03F-5D1
VXK2350-03F-5D1-B
VXK2350-03F-5DL1
VXK2350-03F-5DO1
VXK2350-03F-5DZ1
VXK2350-03F-5DZ1-B
VXK2350-03F-JDOR1
VXK2350-03F-JDR1
VXK2350-03N-1GR1
VXK2350-03N-3CR1
VXK2350-03N-3DR1
VXK2350-03N-5DZ1
VXK2350-03T-5G1
VXK2350-03T-6G1
VXK2350A-03-1DLR1
VXK2350A-03-2DS1-B
VXK2350A-03-2GR1
VXK2350A-03-5D1
VXK2350A-03-5DL1
VXK2350A-03-5DO1
VXK2350A-03-5DZ1
VXK2350A-03-5DZ1-B
VXK2350A-03-5G1
VXK2350A-03N-5D1
VXK2350AZ-03-1GR1-B
VXK2350B-03F-5DL1
VXK2350E-03F-4TZ1
VXK2350S-03-2GS1
VXK2350V-03-1TLR1
VXK2350V-03-5TZ1
VXK2350Z-03-1GR1
VXK2350Z-03-1GR1-B
VXK2350Z-03-2GR1-B
VXK2350Z-03-5DZ1
VXK2350Z-03-5DZ1-B
VXK2350Z-03-5G1-B
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable Fluid Operating Environment Switching Type Connection Type Plumbing Thread Nominal Orifice Dia.
(Ø)
Voltage Sealing materials Bracket Detailed type Functions Valve type Lead wire electrical entry Coil type

MYR 471.90

1 Piece(s) 21 Day(s) WaterStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRNoneVXK23 type valveNoneN.C.GrommetB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRWith BracketVXK23 type valveNoneN.C.GrommetB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRWith BracketVXK23 type valveNoneN.C.Grommet with surge voltage suppressorB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRWith BracketVXK23 type valveNoneN.C.Conduit terminal / With lightB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRNoneVXK23 type valveNoneN.C.Conduit terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRWith BracketVXK23 type valveNoneN.C.Conduit terminal with surge voltage suppressor and lightB

MYR 532.37

1 Piece(s) 21 Day(s) WaterDust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88240 V AC 50/60 HzNBRNoneVXK23 type valveNoneN.C.DIN terminalB

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88230 V AC 50/60 HzNBRWith BracketVXK23 type valveBuilt-in full wave rectifier typeN.C.DIN terminalB

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88110 V AC 50/60 HzNBRWith BracketVXK23 type valveBuilt-in full wave rectifier typeN.C.DIN terminal / With lightB

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88220 V AC 50/60 HzNBRNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.DIN terminalB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88-NBRNoneVXK23 type valveNoneN.C.DIN terminalB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88-NBRWith BracketVXK23 type valveNoneN.C.DIN terminalB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88-NBRNoneVXK23 type valveNoneN.C.DIN terminal / With lightB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88-NBRNoneVXK23 type valveNoneN.C.For DIN terminal (without connector, gasket included)B

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88-NBRNoneVXK23 type valveNoneN.C.DIN terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88-NBRWith BracketVXK23 type valveNoneN.C.DIN terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88230 V AC 50/60 HzNBRNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.For DIN terminal (without connector, gasket included)B

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally ClosedG3/88230 V AC 50/60 HzNBRNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.DIN terminalB

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally ClosedNPT3/88100 V AC 50/60 HzNBRNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.GrommetB

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally ClosedNPT3/88110 V AC 50/60 HzNBRNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.ConduitB

-

1 Piece(s) Quote AirStandard / Dust Resistant / Jet Proof TypeNormally ClosedNPT3/88110 V AC 50/60 HzNBRNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.DIN terminalB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedNPT3/88-NBRNoneVXK23 type valveNoneN.C.DIN terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedNPTF3/88-NBRNoneVXK23 type valveNoneN.C.GrommetB

-

1 Piece(s) Quote WaterStandard / Dust Resistant / Jet Proof TypeNormally ClosedNPTF3/8812 V DCNBRNoneVXK23 type valveNoneN.C.GrommetB

-

1 Piece(s) Quote OilDust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88100 V AC 50/60 HzFKMNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.DIN terminal / With lightB

-

1 Piece(s) Quote OilDust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88200 V AC 50/60 HzFKMWith BracketVXK23 type valveNoneN.C.DIN terminal, with surge voltage suppressorB

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88200 V AC 50/60 HzFKMNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.GrommetB

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-FKMNoneVXK23 type valveNoneN.C.DIN terminalB

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-FKMNoneVXK23 type valveNoneN.C.DIN terminal / With lightB

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-FKMNoneVXK23 type valveNoneN.C.For DIN terminal (without connector, gasket included)B

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-FKMNoneVXK23 type valveNoneN.C.DIN terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-FKMWith BracketVXK23 type valveNoneN.C.DIN terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-FKMNoneVXK23 type valveNoneN.C.GrommetB

-

1 Piece(s) Quote OilStandard / Dust Resistant / Jet Proof TypeNormally ClosedNPT3/88-FKMNoneVXK23 type valveNoneN.C.DIN terminalB

-

1 Piece(s) Quote OilNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88100 V AC 50/60 HzFKMWith BracketVXK23 type valveBuilt-in full wave rectifier typeN.C.GrommetB

-

1 Piece(s) Quote Water / VacuumDust Resistant / Jet Proof TypeNormally ClosedG3/88-EPDMNoneVXK23 type valveNoneN.C.DIN terminal / With lightB

-

1 Piece(s) Quote WaterDust Resistant / Jet Proof TypeNormally ClosedG3/88220 V AC 50/60 HzEPDMNoneVXK23 type valveNoneN.C.Conduit terminal with surge voltage suppressor and lightH

-

1 Piece(s) Quote SteamDust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88200 V AC 50/60 HzPTFENoneVXK23 type valveNoneN.C.Grommet with surge voltage suppressorH

-

1 Piece(s) Quote Air / VacuumNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88100 V AC 50/60 HzFKMNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.Conduit terminal / With lightB

-

1 Piece(s) Quote Air / VacuumNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-FKMNoneVXK23 type valveNoneN.C.Conduit terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote AirNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88100 V AC 50/60 HzNBRNoneVXK23 type valveBuilt-in full wave rectifier typeN.C.GrommetB

-

1 Piece(s) Quote AirNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88100 V AC 50/60 HzNBRWith BracketVXK23 type valveBuilt-in full wave rectifier typeN.C.GrommetB

-

1 Piece(s) Quote AirNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88200 V AC 50/60 HzNBRWith BracketVXK23 type valveBuilt-in full wave rectifier typeN.C.GrommetB

-

1 Piece(s) Quote Air / WaterNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRNoneVXK23 type valveNoneN.C.DIN terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote Air / WaterNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRWith BracketVXK23 type valveNoneN.C.DIN terminal with surge voltage suppressor and lightB

-

1 Piece(s) Quote WaterNo oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc3/88-NBRWith BracketVXK23 type valveNoneN.C.GrommetB
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable Fluid Operating Environment Switching Type Connection Type Plumbing Thread Nominal Orifice Dia.
(Ø)
Voltage Sealing materials Bracket Detailed type Functions Valve type Lead wire electrical entry Coil type

Loading...

Basic Information

Type Electromagnetic Type Driving Type Linear Motion Type Operating Temperature Range(°C) -20::60
Body material C37 Body type Single unit

Additional Products in this Category

Tech Support

Not a MISUMI customer yet? Register & enjoy 50% off your 1st order!* (*T&C apply.)

  • 7 Million Products
  • 2,000 Brands
  • Free CAD downloads
  • Quote/order any time