SPD SR-GVJ Series for Signal Circuits (SR-GV12J)

SPD SR-GVJ Series for Signal Circuits SR-GV12J

SPD/arrestor that is easy to inspect and replace because it is a plug-in type.
[Features]
・ Supports IEC Categories C2 and D1
・ Impulse durability C2: 8/20 μs 10 kA, D1:10/350 μs 5 kA (C2: Positive/negative, 5 times each, 10 times in total, D1: Positive/negative 1 time each, 2 times in total)
・ Supports RS485 line
・ DIN rail compatible
・ Plug-in type (Easy to check and replace)
・ With deterioration display function
・ Ideal for protecting solar power systems
[Applications]
・ Protects RS485 lines from lightning surges

PDF

Japanese Only

Part Number

Configured Part Number is shown.

SR-GV12J

 
Part Number
SR-GV12J
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipVoltage Maximum Continuous Operational Voltage Voltage protection level Frequency bandwidth (reference value)

MYR 952.48

1 Piece(s) 4 Day(s) or more DC12VDC12.6VLine 55V/Ground 400 VDC to 8MHz

Loading...

  1. 1

Basic Information

Application RS485 line Type Single pole type Mounting Method Clamp type
Class, category IEC category C2 / IEC category D1 Dimension vertical(mm) 98 Dimension width(mm) 23
Dimension depth(mm) 72.5 Impulse resistance (8/20 μs) 10kA Impulse resistance (10/350 μs) 5kA

Please check the type/dimensions/specifications of the part SR-GV12J in the SPD SR-GVJ Series for Signal Circuits series.

Products like this...

Part Number
SR-GV5J
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipVoltage Maximum Continuous Operational Voltage Voltage protection level Frequency bandwidth (reference value)

MYR 952.48

1 Piece(s) 4 Day(s) or more DC5VDC5.5VLine 45V/Ground 400 VDC to 140MHz

Additional Products in this Category