(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Kindly be informed that it will be peak period in conjunction with the Chinese New Year festive season. Delivery pickup upon 25 January 2025 estimated would arrive after CNY holidays. Please expect slight delay for orders shipped during this peak season and we thank you for your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Transformer EP Series

Transformer EP Series

Single-phase compound / P-type terminal block, primary voltage 200V 220V secondary voltage 100V 110V built-in self-holding thermal protector with shield (E).

[Features]
· To improve the security of electronic equipment, once the setting temperature for non-automatic recovery (bimetallic element) is reached, snap action (switch) is disconnected, and electronic grounding is in parallel. To avoid the heat inverted by bi-metal from the PTC heater's switch-on, the connection is disconnected till the power of transformer or electronic equipment is off.
· Ceramics PTC (automatic temperature adjustment) built-in.
· EN standards (a voltage maintenance type device for preventing excessive temperature rises).
· Satisfies the requirement for holding a temperature of -20° at 250 VAC.
· UL specifications with requirement of "0°C-keeping" is satisfied when 125/250Vac is applied.
· Voltage range AC90V to 250V (exclusively for AC circuit)

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
EP-1KE
EP-300E
EP-500E
EP-750E
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCapacity
(kVA)
Height
(mm)
Dimension width
(mm)
Depth
(mm)

MYR 1,397.36

1 Piece(s) 28 Day(s) or more 1156153175

MYR 661.60

1 Piece(s) 22 Day(s) or more 0.3120120120

MYR 901.67

1 Piece(s) 22 Day(s) or more 0.5156153135

MYR 1,331.85

1 Piece(s) 24 Day(s) or more 0.75156153145

Loading...

  1. 1

Basic Information

Number of phases/winding Single-phase/Double-winding Primary voltage(V) 200 Secondary voltage(V) 100
Shield Available Insulation type A Input/output terminal shape Terminal block type (P)
With/without Case NA Primary voltage range AC200-220 Secondary voltage range AC100-110

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)