(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

LFA300F Model 300W Single Output

LFA300F Model 300W Single Output

Single substrate / worldwide input / compact input (300W Single output)

[Features]
· Miniaturization (footprint reduced by 23% compared with the past) The same floor area as LEP240F Product height is different.
· For reduced standby power (1.1WtypatAC200V) when remote control is off, set option "-R2."
· Adoption of screw dropout prevention mechanism on input and output terminal block.
· High efficiency by adopting synchronous rectification (3.3, 5 V product).
· Harmonic current regulations (IEC61000-3-2) conforming.
· The 24V type achieves natural air cooling at 300W (peak 456W.)
· Forced air fan built-in option set "-SNF."
· Exclusive harness etc., full options SEMIF47 spec compliance.

PDF

Part Number

Configured Part Number is shown.

LFA300F-12-TY

INDEX

 

Features of LFA300F

LFA300F

LFA300F

Downsizing (28% reduction in floor area compared to the conventional model) same floor area as LGA240 A

  • * Product height differs. Please check the specifications for details.

When the remote control is off, the option "-R2" with reduced standby power (1.1 W typ at 200 V AC) is set
Screw fall prevention mechanism is used for input and output terminal blocks
High efficiency by adopting synchronous rectification (3.3, 5 V product)
Harmonic current regulation compliant (Compliant with IEC61000-3-2)
24 V has achieved natural air cooling 300 W (peak 456 W)
The option "-SNF" with built-in forced draft fan is set (5 V, 12 V, 24 V)
Extensive optional parts such as dedicated harness
Compatible with SEMI F47 standard

  • * This product uses surface mount components. Please be careful not to give stress such as twisting or impact to the circuit board.

Ordering information of LFA300F

Ordering information

1 Series name
2 Single output
3 Rated output power
4 Full range input
5 Rated output voltage
→6 continues to the right

6 options
C: Coating
G: Low leakage current
H: Peak current compatible (24 V or more)
J: EP (Tyco Electronics) connector (12 V or more)
J1: VH (J.S.T) connector (12 V or more)
R: With remote ON/OFF
R2: With remote control
S: With chassis
SN: With chassis and cover
SNF: With fan (5 V, 12 V, 24 V)
T: Terminal block horizontal type
Y: With potentiometer

Block diagram

Block diagram
 

Drawing

Drawing
  • * The external shape is different for options. The parts positions without dimensional instructions in the figure are for reference only.
  • * Since the surface mount parts are mounted on the back side, please be careful about contact in consideration of vibration.
  • * Please use a spacer of 8 mm or more.
  • * There are 5 mounting holes in total.
  • * Point A, point B, point C, and point D are temperature measurement points.
  • * General tolerance: ±1
  • * Please use TB2 at 20 A or less per pin.
  • * Terminal block tightening torque M4: 1.6 N⋅m (16.9 kgf⋅cm) max
  • * Weight: 810 g max (With chassis and cover: 1,270 g max)
  • * Circuit board: Glass composite (CEM3)
  • * Please check the manufacturer web site or catalog for details of the product.

Product specifications

ItemLFA300F-3R3-TYLFA300F-5-TYLFA300F-12-TYLFA300F-15-TYLFA300F-24-TYLFA300F-24-HTYLFA300F-30-TYLFA300F-36-TYLFA300F-48-TY
Maximum output power [W]*5198300324330336336 (456)330338.4336
DC output *5Natural air cooling3.3 V 40 A5 V 40 A12 V 17 A15 V 14 A24 V 12.5 A24 V 12.5 (19) A30 V 10 A36 V 8.4 A48 V 6.3 A
Forced draft fan3.3 V 60 A5 V 60 A12 V 27 A15 V 22 A24 V 14 A24 V 14 (19) A30 V 11 A36 V 9.4 A48 V 7 A
InputVoltage [V]AC85 to 264 1⌀ (Refer to the section 1.1 and section 3.2 of the instruction manual) *4
Current [A]ACIN 100 V2.7 typ (lo = 100%)4.1 typ (lo = 100%)
ACIN 200 V1.4 typ (lo = 100%)2.0 typ (lo = 100%)
Frequency [Hz]50/60 (47 to 63)
Efficiency [%]ACIN 100 V75.0 typ79.0 typ80.0 typ81.5 typ85.0 typ85.0 typ85.5 typ85.5 typ85.5 typ
ACIN 200 V77.0 typ82.5 typ83.0 typ84.5 typ88.0 typ88.0 typ88.0 typ88.0 typ88.0 typ
Power rate (lo = 100%)ACIN 100 V0.98 typ0.99 typ
ACIN 200 V0.92 typ0.95 typ
Inrush current [A]ACIN 100 V15/30 typ (lo = 100%) (Primary inrush current value / secondary inrush current value) (Re-input interval of 3 seconds or more)
ACIN 200 V30/30 typ (lo = 100%) (Primary inrush current value / secondary inrush current value) (Re-input interval of 3 seconds or more)
Leakage current [mA]0.45/0.75 max (According to each measurement method of 100 V/240 V AC Input 60 Hz, lo = 100%, IEC60950-1, the Electrical Appliances and Materials Safety Act)
OutputRated voltage [V]3.3512152424303648
Rated current [A]*5Natural air cooling4040171412.512.5 (Peak 19)108.46.3
Forced draft fan606027221414 (Peak 19)119.47
Static input fluctuation [mV]*720 max20 max48 max60 max96 max96 max144 max144 max192 max
Static load fluctuation [mV]*740 max40 max100 max120 max150 max150 max240 max240 max240 max
Ripple [mVp · p]0 to +40°C ※280 max80 max120 max120 max120 max240 max150 max150 max150 max
-10 to 0°C ※2140 max140 max160 max160 max160 max320 max200 max200 max200 max
Ripple noise [mVp · p]0 to +40°C ※2120 max120 max150 max150 max150 max300 max250 max250 max250 max
-10 to 0°C ※2160 max160 max180 max180 max180 max360 max300 max300 max300 max
Ambient temperature fluctuation [mV]0 to +40°C50 max50 max120 max150 max240 max240 max360 max360 max480 max
-10 to +40°C60 max60 max150 max180 max290 max290 max450 max450 max600 max
Drift over time [mV]*320 max20 max48 max60 max96 max96 max144 max144 max192 max
Startup Time [ms]350 typ (100 V AC Input, lo = 100%)
Retention time [ms]20 typ (100 V AC Input, lo = 100%)
Variable voltage range [V]2.85 to 3.634.50 to 5.5010.80 to 13.2013.50 to 16.5021.60 to 27.5021.60 to 27.5027.00 to 33.0032.40 to 39.6039.60 to 52.80
Voltage setting accuracy [V]3.30 to 3.405.00 to 5.1512.00 to 12.4815.00 to 15.6024.00 to 24.9624.00 to 24.9630.00 to 31.2036.00 to 37.4448.00 to 49.92
Functions includedOvercurrent protectionIt operates at 105% min of rated current (101% min of peak current if there is peak current) and automatically returns
Overvoltage protection [V]4.00 to 5.255.75 to 7.0013.80 to 16.8017.25 to 21.0027.60 to 33.6027.60 to 33.6034.50 to 42.0041.40 to 50.4055.20 to 67.20
Operating indicationN/A
Remote sensingN/A
Remote ON/OFF (RC)Option (External drive power supply required)
Dielectric strengthInput - output / RC *63,000 V AC 1-minute cutoff current = 10 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity)
Input - FG2,000 V AC 1-minute cutoff current = 10 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity)
Output / RC - FG *6500 V AC 1-minute cutoff current = 25 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity)
Output - RC *6100 V AC 1-minute cutoff current = 25 mA, 100 V DC 10 MΩ min (Normal temperature, normal humidity)
EnvironmentOperating temperature and humidity *4-10 to +70°C, 20 to 90%RH (No condensation) (Refer to the section 3.2 of the instruction manual)
Storage temperature/humidity-20 to +75°C, 20 to 90%RH (No condensation)
Vibration10 to 55 Hz 19.6 m/s^2 (2 G) period 3 minutes X, Y, Z direction 1 hour each
Impact196.1 m/s^2 (20 G) 11 ms X, Y, Z direction 1 time each
Compatible standardSafety StandardUL60951-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178-acquired, the Electrical Appliances and Materials Safety Act compliant
Conducted EmissionsFCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B compliant
Harmonic currentIEC61000-3-2 (Class A) compliant *8
StructureExternal dimensions / weight95 × 52.5 × 222 mm (W × H × D)(excluding terminal block) / 810 g max (With chassis and cover: 1,270 g max)
Cooling methodNatural air cooling / forced draft fan (Refer to the section 3.1 and section 3.2 of the instruction manual) *4
  • *1 Specifications differ when options are set. Please contact the manufacturer support center for details.
  • *2 It is a value on a measuring board with a 22 mF capacitor attached to the point at 150 mm from the output terminal. (By 20 MHz oscilloscope or ripple noise meter (KEISOKUGIKEN: RM-103 equivalent)).
  • *3 Drift over time is at ambient temperature of 25°C. It is a change during 30 minutes to 8 hours after applying the input voltage at the rated input/output.
  • *4 Output derating is required. Please contact the manufacturer support center for use with DC.
  • *5The values in (parentheses) indicate the peak values. Please refrain from continuous use at peak currents.
    It may destroy the internal elements.
    There is a limit to the peak current (time / duty).
  • *6 "RC" is applied when adding a remote control (option).
  • *7 In case of dynamic fluctuation, the specification may not be satisfied.
  • *8 Please contact the manufacturer support center for other classes.
  • * Please avoid using it in an overloaded state or outside the specification range, as it may damage the internal elements.
  • * Parallel operation is not possible.
  • * Derating is required if the chassis and cover are included.
  • * Sound noise may be heard from the power supply when used for pulse load.
 

Lineup and features

Circuit board starter type

Circuit board starter type

Number of outputsSeries nameRelease yearMain featuresSafety Standard
Environmentally friendly
Circuit board starter typeSingle1GHA'133 × 5 inch external shape, compatible with medical electrical equipment, high power density with electric cooling functionUL and C-UL certified product / DEMKO certified product / CE marking compliant product
'15- SNF: Option with fan
'16
1LMA'14Compatible with medical electrical equipment, peak compatibleUL and C-UL certified product / DEMKO certified product / CE marking compliant product
1LFP'12Peak current compatible,
LEP series compact version
UL and C-UL certified product / TUV certified product / CE marking compliant product
'13
1LEP'02Peak current compatibleUL and C-UL certified product / TUV certified product / CE marking compliant product
1LFA'09Circuit board starter type general-purpose power supply,
LEA series compact version
UL and C-UL certified product / TUV certified product / CE marking compliant product
'10
SPLFA'11LFA series (with chassis and cover) PSE-acquired productThe Electrical Appliances and Materials Safety Act certified product
1LEA'99Circuit board starter type general-purpose power supplyUL and C-UL certified product / TUV certified product / CE marking compliant product
1LDA'94Circuit board starter type general-purpose power supplyUL and C-UL certified product / CSA certified product / TUV certified product / CE marking compliant product
'95
'97UL certified product / C-UL certified product / TUV certified product / CE marking compliant product
1LGA'08Input 100 V AC system circuit board starter type general-purpose power supplyUL and C-UL certified product / TUV certified product / CE marking compliant product
Multi2LEB'00LEA series 2-output typeUL and C-UL certified product / TUV certified product / CE marking compliant product
3LDC'94LDA series 3-output typeUL and C-UL certified product / CSA certified product / TUV certified product / CE marking compliant product
'95
2LB'92Circuit board starter type 2-output power supply,
low price has been achieved by limiting performance and functions
Linear typeSingle
Multi
1G'75100 V AC system input, linear power supply, ultra-low noise and low ripple
2GW'75G series 2-output type
 

Development story

 

By using the same external shape and mounting as those of the 100 V AC (85 to 132 V) LGA series (output power 50 to 240 W), it is easy to replace even if the customer urgently requests 200 V AC compatibility.
In addition, by expanding the lineup with models from 10 to 305 W as a circuit board starter power supply, even if using multiple units, it is possible to arrange them in the same series.

Part Number
LFA300F-12-TY
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOutput voltage (Single only) Rated output current (single only)
(A)
Maximum output power
(W)
Voltage settings reliability
(V)
Output voltage variation
(V)

MYR 845.47

1 Piece(s) 12 Day(s) or more 10DC12V2732412 to 12.4810.8 to 13.2

Loading...

  1. 1
 

Basic Information

Shape Open frame Output power(W) 300 Single/multi Single
Input Voltage AC-dedicated Input/output terminal shape Terminal Block Safety standards CE / UL / CUL / TUV / CSA
Height(mm) 52.5 Width(mm) 95 Depth(mm) 222
Input Voltage(V) AC85 to 264 Excess current protective circuit Available Excess voltage protective circuit Available
Terminal block type Vertical Other optional functions With volume

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)