(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

In-Line Type Ribbon Cable Connector (HIF3B Relay Type) (HIF3BA-34PD-2.54R-MC)

In-Line Type Ribbon Cable Connector (HIF3B Relay Type) HIF3BA-34PD-2.54R-MC

Can be used for cable-to-cable wiring inside machinery. The HIF3B series socket is also compatible with the HIF3A series.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

HIF3BA-34PD-2.54R-MC

In-line Type Ribbon Cable Connector (HIF3B Relay Type)

HIF3BA-PD Series

HIF3BA-PD Series

Specifications of HIF3BA-PD Series In-Line Male Connector For ID

Product Standards

RatingRated current: 1 A
Rated voltage: 200 V AC
Operating temperature range: -55 to +85°C (Note 1)
Operating humidity range: 40 to 80%
Storage temperature range -10 to +60°C (Note 2)
Storage humidity range 40 to 70% (Note 2)
ItemStandardConditions
1. Insulation resistance1,000 MΩ or moreMeasure at 500 V DC
2. Withstand voltageThere shall be no flashover or dielectric breakdown.Energize at 650 V AC rms for 1 min.
3. Contact resistance15 mΩ or lessMeasure at 0.1 A
4. Vibration resistanceThere shall be no electrical discontinuity for 1 μs or greater.10 to 55 Hz, Single amplitude: 0.75 mm, Three directions, 2 hours
5. Humidity resistanceInsulation resistance: 1,000 MΩ or moreLeave at temperature 40°C ±2°C and humidity 90 to 95% for 96 hours
6. Temperature cycleThere shall be no cracking or abnormalities with any of the parts.(-65°C: 30 mins. > 15 to 35°C: Max. 5 mins. >
125°C: 30 mins. > 15 to 35°C: Max. 5 mins.) 5 cycles
7. Durability (Mating / Un-mating)Contact resistance: 15 mΩ or less500 times

(Note 1) This includes temperature increases caused by the flow of current.
(Note 2) The term "storage" refers to products stored for long periods of time prior to mounting and use. The operating temperature range and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation.

Materials

Part NameMaterialsFinishNote
InsulatorPBT resinBlackUL94V-0
Plug contactBeryllium copperNickel plating + gold plating-

Product Outline Drawing And Dimensions

Plug

Plug

Plug

HIF3BA-PD Series In-Line Male Connector For ID dimensional drawing

HIF3BA-PD Series In-Line Male Connector For ID dimensional drawing

  • (Note 1) (Note 2): Because the number of slots with polarity vary depending on the product, contact VONA Customer Service (0120-343-256) for details. Only the 10-contact model does not have a polarity key mounting section.
  • (Note 3): Dimensions shown in parentheses are for 60- and 64-contact models.
  • (Note 4): Be aware that although the lock shape of the HIF3BAE-60PD-2.54R-MC is partially different, its only mating partner is HIF3A.

Connection Method

When using with cable such as twisted cable or slitted cable, because the cable pitch may differ slightly depending on the cable manufacturer, it may not be possible to complete wiring. In such cases, please contact the cable manufacturer.

When using with cable such as twisted cable or slitted cable, because the cable pitch may differ slightly depending on the cable manufacturer, it may not be possible to complete wiring. In such cases, please contact the cable manufacturer.

AO Type

Front view

Front view

Side cross-sectional view

Side cross-sectional view

BO Type

Front view

Front view

Side cross-sectional view

Side cross-sectional view

CO Type

Front view

Front view

Side cross-sectional view

Side cross-sectional view

DO Type

Front view

Front view

Side cross-sectional view

Side cross-sectional view

Part Number
HIF3BA-34PD-2.54R-MC
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSNumber Of Pins

MYR 51.06

1 Piece(s) 4 Day(s) or more 1034

Loading...

  1. 1

Basic Information

Connector Shape Rectangular Connector series initials M/N/O M/N/O MIL
Applicable pin/contact Male Connector Type Cable to cable Rated Current(A) 1
Allowable Voltage(V) AC200 Wiring Method Pressure Welding Connection direction Straight
Representative Standard UL Conforming Cable UL2651 AWG28 flat cable (x7/φ 0.127mm, outer sheath diameter 0.8 to 1.0 mm) Conforming cable outer diameter(mm) φ 0.8 to 1.0
Polarity Guide/Slot Center 1 Operating Temperature Range(°C) -55 to +85 Terminal pitch(mm) 2.54

Please check the type/dimensions/specifications of the part HIF3BA-34PD-2.54R-MC in the In-Line Type Ribbon Cable Connector (HIF3B Relay Type) series.

Products like this...

Part Number
HIF3BA-20PD-2.54R-MC
HIF3BA-40PD-2.54R-MC
HIF3BB-50PD-2.54R-MC
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSNumber Of Pins

MYR 41.78

1 Piece(s) 2 Day(s) 1020

MYR 51.91

1 Piece(s) 2 Day(s) 1040

MYR 64.61

1 Piece(s) 4 Day(s) or more 1050

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)