(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Rocker switch with reset function for high-capacity switching.
[Features]
・ Effective for energy saving with reset function by external signal
・ Achieves excellent inrush current performance and 20 A opening and closing with a unique opening and closing mechanism
・ Contact configuration is 2-pole double heads
・ Contact gap 3 mm or more
・ UL, cUL accredited. EN standard compliant
[Applications]
・ As an operation / power supply / changeover switch for various devices
Japanese Only
Part Number
Configured Part Number is shown.
A8G-107-1-24
A8G series appearance
Unit: mm
Operating properties
Force required for operation OF Max: 19.6 N
Item | Non-inductive Load (A) | Inductive Load (A) | ||
---|---|---|---|---|
Rated Voltage (V) | Resistive Load | Lamp Load | Inductive Load | Electric Motor Load |
250 V AC | 20 | 10 | 8 | 8 |
Note 1. Lamp load has a 10x inrush current.
Note 2. Inductive loads will have a power factor of 0.4 or higher (AC).
Note 3. Electric motors have a 6x inrush current.
Note 4. The rated values described above were tested in the conditions below.
Rated Voltage (V) (Usable Voltage Range) | Open Contact Voltage (Coil Temperature 20 ±2°C) | Rated Value Excitation Current (Coil Temperature 20 ±2°C) | Coil Resistance (Coil Temperature 20 ±2°C) | Permitted Application Time |
---|---|---|---|---|
24 V DC ±10% (21.6 to 26.4 V DC) | 21.6 V or less | 185 mA ±20% | 130Ω ±20% | 100 ms or more 1s or less |
Note 1. Please do not flow current to the coil for over 10 seconds. This may cause loss of performance.
Note 2. If the reset coil is controlled using a semiconductor element, etc., make sure that any residual voltage generated due to leakage current is 2.4 V DC or less.
Permitted Operation Frequency | Mechanical | Switch operation: 7 times/min. or less; Coil operation: 7 times/min. or less |
---|---|---|
Electrical | 20 times/min. or less | |
Insulation Resistance | 100 MΩ or higher (insulation resistance meter at 500 V DC) | |
Contact Resistance (Initial Value) | 100 mΩ or lower (6 to 8 V DC, 1 A voltage drop method) | |
Withstand Voltage | Between Same Pole Terminals | 2,000 V AC 50/60 Hz 1 min |
Between Different Pole Terminals | 2,000 V AC 50/60 Hz 1 min | |
Metal And Ground Components For Charging | 4,000 V AC 50/60 Hz 1 Min. | |
Vibration | Malfunction | 10 to 55 Hz double amplitude 1.5 mm (malfunction within 1 ms) |
Shock | Malfunction | 98 m/s2 or higher (malfunction within 1 ms) |
Durability | Max. 500 m/s2 | |
Durability | Electrical | Switch operation: 50,000 times or more; Coil operation: 10,000 times or more |
Mechanical | Switch operation: 100,000 times or more | |
Inrush Current | Max. 100 A | |
Protective Structure | IEC IP40 | |
Open Contact Time * | 100 ms or less | |
Operating Temperature Range | -10 to +55℃ (with no icing and no condensation) | |
Operating Humidity Range | 45 to 85% |
*Time between applying voltage to the coil and when the contact (between 1-2, 4-5) opens.
Part Number |
---|
A8G-107-1-24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
---|---|---|---|---|
MYR 66.23 | 1 Piece(s) | 2 Day(s) |
Loading...
Shape | Rectangle | Illumination | Non-Illumination | Contact Configuration | 2-pole double throw |
---|---|---|---|---|---|
With key | NA | Terminal shape | Tab Terminal | Protection function (environmentally resistant) | Available |
Dimension vertical(mm) | 37 | Dimension width(mm) | 27 | Dimension depth(mm) | 33 |
Contact rated 1 (resistant load)(V)/(A) | AC250/20 | Works with micro loads | NA | Reset function (external control) | Available |
Operation Unit | Integrated style | Operating unit marking | NA | Button color | Black |
Case color | Black | Protective Structure | IP40 |
Please check the type/dimensions/specifications of the part A8G-107-1-24 in the Locker Switch With Reset Function A8G series.
MISUMI
Standard Price : MYR 71.05-
Days to Ship : 2 Day(s) or more
MIYAMAELECTRIC
Standard Price : MYR 17.23-
Days to Ship : 2 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy