(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Please note that some of the items may take longer lead time to ship due to Japan New Year holidays (29-Dec-2024 to 5-Jan-2025). Early order placement is recommended. We apologize for the inconvenience caused and appreciate your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Surface-mount Relay - G6L (G6L-1P DC5)

Surface-mount Relay - G6L G6L-1P DC5

[Features]
· An ultra-thin single pole flat relay with the lowest profile in its class.
· Requires approximately 20% less surface area for mounting and has approximately 64% the volume (compared to the manufacturer's G5V-1). This enables high-density mounting (width: 7.0 mm × length: 10.6 mm × height: 4.5 mm (SMD), 4.1 mm (TH)).
· High withstand voltage between coil-contacts of AC1,000V. Also boasts impulse voltage resistance of 1.5kV10 × 160 μs (FCCPart68 compliant).
· High withstand voltage between identical polarity contacts of 750V.
· Surface mounted types also available.
· The standard type is UL and CSA standard certified.
· Uses absolutely no lead.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

G6L-1P DC5

Surface Mount Relay G6L Series Specifications

Surface Mount Relay G6L: related images

Model G6L-1P outline drawing

Surface Mount Relay G6L: related images

Note: The general dimensional tolerance is ±0.3 mm.

Surface Mount Relay G6L: related images

The dimensional tolerance is ±0.1 mm.

Ratings

ItemsRated Current
(mA)
Coil Resistance
(Ω)
Operating Voltage
(V)
Release Voltage
(V)
Maximum Allowable Voltage
(V)
Power Consumption
(mW)
Rated Voltage (V)
DC536.0139.075% or Less10% or More150%Approx. 180
1215.0800.0

Note 1: The rated current and coil resistance are measured at a coil temperature of +23°C and a tolerance of ±10%.
Note 2: The operating characteristics are measured at a coil temperature of +23°C.
Note 3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Note 4: Measurements for Turn ON/Turn OFF voltage are values measured using instantaneous changes in voltage (rectangular waves).

Performance

TypeSingle Stable Type
ModelModel G6L-1P
Contact Resistance *1100 mΩ or Less
Operating Time *25 ms or Less (Approx. 1.1 ms)
Turn OFF Time *25 ms or Less (Approx. 0.4 ms)
Insulation Resistance *31,000 MΩ or More (at 500 V DC)
Withstand VoltageBetween Coil and Contact1,000 V AC 50/60 Hz 1 min
Between Contacts of Same Polarity750 V AC 50/60 Hz 1 min
Impulse Withstand VoltageBetween Coil and Contact1,500 V 10 × 160 μs
VibrationDurability10 to 55 Hz Semi-Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Malfunction10 to 55 Hz Semi-Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Shock / ImpactDurability1,000 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 Times or More (Switching Frequency: 36,000 Times/h)
Electrical100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h)
Failure Rate P Level (Reference Value *4)5 V DC, 1 mA
Ambient Operating Temperature-40 to +70°C (Assuming No Freezing or Condensation)
Operating Ambient Humidity5 to 85%RH
WeightApprox. 0.6 g

Note: The above values are the initial default values.
*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
*4. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 100 Ω.
These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.

  • *Refer to the catalog for other specifications.
Part Number
G6L-1P DC5
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCoil rated voltage (DC)
(V)

MYR 20.05

1 Piece(s) 2 Day(s) 5

Loading...

  1. 1
 

Basic Information

Application For Signals Contact Configuration 1a Latch function NA
Terminal shape For Circuit Boards Contact rated current (minimum value for AC and DC)(A) 0.3 Dimension height(mm) 4.1
Dimension width(mm) 10.6 Dimension depth(mm) 7 Classification Single stable shape
Protective Structure Plastic seal type Contact mechanism Crossbar twin Circuit Board Mounting Circuit Board Hole Insertion
AC rated load(V)/(A) AC125/0.3 DC rated load(V)/(A) DC24/1

Please check the type/dimensions/specifications of the part G6L-1P DC5 in the Surface-mount Relay - G6L series.

Products like this...

Part Number
G6L-1P DC12
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCoil rated voltage (DC)
(V)

MYR 20.05

1 Piece(s) 2 Day(s) 12

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)