(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Please note that some of the items may take longer lead time to ship due to Japan New Year holidays (29-Dec-2024 to 5-Jan-2025). Early order placement is recommended. We apologize for the inconvenience caused and appreciate your kind understanding. [Details]
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Daily time switch H5L (Part Numbers)

Daily time switch H5L

[Features]
· Weekly control using a large clock display.
· A daily time switch of a setting type that can be set while in dialog with both sides, and with a large display with a clock.
· Simple to operate with five keys.
· ON/OFF time schedule setting has 24 steps.
· AC100 to 230V free power source.
· Has a warranty for long duration power outage (approx. 10 years).
· International safety standard UL, CSA acquired.
· Day-to-day operations are possible with the same settings as timer operation.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

H5L-A

Daily Timer Switch H5L Specifications

Daily Timer Switch H5L: related image

H5L-A external appearance

Daily Timer Switch H5L: related image

H5L-A dimensional drawing
Units: mm
Note: Values in parentheses are the dimensions when the Y92A-96A front cover (sold separately) is installed.

Daily Timer Switch H5L: related image

Dimensional drawing when embedded
Panel cut size (DIN 43700 compliant)
Units: mm
Note: Mounting panel plate thickness is 1 to 3.2 mm.

Daily Timer Switch H5L: related image

Dimensional drawing when surface mounted
Mounting hole processing dimensional drawing
Units: mm

Daily Timer Switch H5L: related image

Dimensional drawing when DIN rail mounted
Units: mm
*1 For PFP-100N, PFP-50N.
* 2 for Series PFP-100N2.

H5L-A Type

Wiring MethodScrew-Fastening Terminal
Control Output2 Circuit (1a × 2)
Single Cycle Time24 h × 7 days (work day can be specified)*
Minimum Setting Unit1 min units
Number Of Program Steps (2 Circuits Total)24 (1 step for ON or OFF)
FormatSeries H5L-A

*The decision to run the program can be set daily for each day of the week.

H5L-A Time Specifications

  • Minimum display time: 24 h × 7 days
  • Setting time range: 0 h 0 min to 23 h 59 min
  • Minimum setting interval: 1 min

H5L-A Rating

Power Supply Voltage100 to 240 V AC, 50/60 Hz (Common)
Allowable Voltage Variation Range85 to 110% of power supply voltage
Power ConsumptionApprox. 4 VA (When 240 V AC)
Control Output*250 V AC, 15 A resistant load (ambient temperature 50°C)
250 V AC, 12 A (Japanese Act on Product Safety of Electrical Appliances and Materials certified rating) resistive load (ambient temperature 55°C)
Power Failure Compensation MethodLithium Battery System
Ambient Operating Temperature-10 to +55℃ (No Freezing)
Ambient Operating Humidity35 to 85%
Case ExteriorLight Gray (Munsell 5Y7/1)

*Minimum applied load 5 V DC, 100 mA (P level, reference value)

H5L-A Performance

Variations In Operating Time(±0.01% ±0.05 s) or less *1
Set Error
Voltage Effect
Temperature Effect
Time Accuracy±15 s/month (at 25°C)
Compensation Time For Power OutageContinuous 10 years or more (25°C) *2
Insulation Resistance100 MΩ or more
Test PointsI Between conductive part terminal and exposed non-charging metal part
II Between operation power supply circuit and contact control output circuit
III Between discontinuous contacts
Withstand Voltage2,000 V AC, 50/60 Hz, 1 min (test points are insulation resistance test points I, II)
1,000 V AC, 50/60 Hz, 1 min (test point is insulation resistance test point III)
Impulse Voltage3 kV between operation power supply terminals
4.5 kV between conductive part terminal and exposed non-charging metal part
Noise ResistanceSquare-wave noise by noise simulator
2 kV (width 100 ns, rise 1 ns, polarity ±, phase 0 to 360°)
Electrostatic Strength8 kV (Malfunction)
VibrationEndurance10 to 55 Hz, half amplitude 0.375mm, 3 directions, 2 h each
Malfunction10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each
ShockEndurance300 m/s2, 6 directions, 3 times each
Malfunction100m/s2, 6 directions, 4 times each
Life100,000 operations or more (resistive load, 250 V AC, 15 A)
MassApprox. 350g

*1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are within (±0.01% ±0.05 s). Additionally, ±0.01% is the value for the set time interval.
*2. Display and output are not available when the power supply is OFF.

Part Number
H5L-A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 1,046.05

1 Piece(s) 2 Day(s)

Loading...

  1. 1
 

Basic Information

Type Timer Display method Liquid Crystal Mounting Method Panel / surface mount (shared)
Time specifications(s) 1 min – 23 h 59 min × 7 days Power Supply Voltage AC/DC Output Method Relay
Dimension vertical(mm) 96 Dimension width(mm) 96 Dimension depth(mm) 56.5
Rated power supply voltage(V) AC 100–240 Contact Configuration 1a×2

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)