Digital Tachometer (DIN48×48) H7CX-R□-N

Digital Tachometer (DIN48×48) H7CX-R□-N

[Features]
· type H7CX tachometer dedicated apparatus (DIN48 × 48 mm) (RPM/speed/flow volume etc. displayed, enabled output of warnings.
· Socket type allows either embedded installation or surface installation.
· W type can be added enabling measurement control with two systems.
· Four modes of operation of up-down reduction/range/upper limit/lower limit are possible.
· Built-in auto zero time, mean number of revolutions, start-up compensation timer, etc.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

H7CX-R11-N

Digital Tachometer Specifications

Digital Tachometer (DIN 48 × 48) H7CX-R□-N: related image

H7CX-R□-N external appearance

Digital Tachometer (DIN 48 × 48) H7CX-R□-N: related image

H7CX-R□-N dimensional outline drawing, units: mm

Digital Tachometer (DIN 48 × 48) H7CX-R□-N: related image

H7CX-R□-N dimensional outline drawing, units: mm

Features

  • H7CX tachometer dedicated model (DIN 48 × 48 mm)
    (Can display RPM / speed / flow volume / etc.; can output warnings)
  • Socket type allows both embedded mounting and surface mounting
  • 4 operational modes possible with one unit; upper/lower limit, range, upper limit and lower limit
  • Built-in auto zero time, mean number of revolutions, start-up compensation timer, etc.
TypeTachometer
FormatSeries H7CX-R11□-N
ItemInput Mode1 input only
RatingPower Supply Voltage*1· 100 to 240 V AC, 50/60 Hz
· 24 V AC, 50/60 Hz / 12 to 24 V DC
Allowable Voltage Variation Range85 to 110% of rated power supply voltage (90 to 110% for 12 to 24 V DC)
Power ConsumptionApprox. 9.4 VA (100 to 240 V AC), Approx. 7.2 VA / 4.7 W (24 V AC / 12 to 24 V DC), Approx. 3.7 W (12 to 24 V DC)
Mounting MethodEmbedded mounting, surface mounting (common)
External Connection Method11-Pin Socket
Protective StructureIEC standard IP66, UL508 Type 4X (indoors), panel surface only (when using waterproof packing Y92S-29)
Input SignalCount, Hold
Pulse Measurement MethodTachometer Mode
(Cycle Measurement)
AMD Compatible Mode
(Continuous Measurement)
Maximum Counting Speed30 Hz
(Minimum Pulse Width 16.7 ms)
10 kHz
(Minimum Pulse Width 0.05 ms)
-
Minimum Input Signal Width-10 ms1 ms
Measurement Range0.001 to 30.00 Hz0.001 Hz to 10 kHz0.026 to 999,999 s0.003 to 999,999 s
Sampling CycleMinimum 200 msContinuous (Minimum 10 ms Intervals)
Display Refresh Cycle· When input pulse is 5 Hz or more
When averaging function is not used: 200 ms
When averaging function is used: 200 × average number of times (ms)
· When input pulse is less than 5 Hz
When averaging function is not used: maximum twice the input pulse cycle
When averaging function is used: maximum twice the (input pulse cycle × average number of times)
Measurement Accuracy±0.1% F.S. ±1 digit or less (at 23±5°C)
Output ModeUpper/lower limit, range, upper limit, lower limit
Auto Zero Time0.1 to 999.9 s (for tachometer mode only)
Start-Up Compensation Timer0.0 to 99.9 s
Averaging FunctionSimple average / moving average selectable, number of times: OFF / 2 times / 4 times / 8 times
Pre-Scale Function0.001 to 99.999 (for tachometer mode only)
Decimal Point SettingBottom 3 digits
Sensor Wait Time290 ms or less (during sensor wait time, input is not accepted with control output OFF)
InputInput MethodNon-voltage input
Impedance at short circuit: 1 kΩ or less (at 0 Ω outflow current: approx. 12 mA)
Residual voltage at short circuit: 3 V or less
Impedance when opening: 100 kΩ or more
Voltage input
"H" level: 4.5 to 30 V DC
"L" level: 0 to 2 V DC (input resistance approx. 4.7 kΩ)
Non-voltage (NPN) input / Voltage (PNP) input (switchable)
HoldMinimum input signal width: 20 ms
Power Supply To External Equipment12 V DC (±10%) 100 mA
Control OutputContact output 250 V AC / 30 V DC, 3 A resistive load (cosφ = 1), minimum applied load: 5 V DC 10 mA (P level, reference)
Display Method*27-segment negative LCD
Character height, measurement values: 10 mm (red), comparison values: 6 mm (green)
Number Of Digits6 digits, 0 to 999,999
Power Failure Memory MethodEEP-ROM (100,000 rewrites or more) data retention: 10 years or more
Ambient Operating Temperature-10 to +55°C (during close contact mounting: -10 to +50°C) (no freezing or condensation)
Storage Temperature Range-25 to +70°C (No Freezing Or Condensation)
Ambient Operating Humidity25 to 85%
Case ExteriorBlack (N1.5)

*Refer to the catalog for specifications other than those listed above.

Part Number
H7CX-R11-N
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 766.00

1 Piece(s) 2 Day(s)

Loading...

  1. 1
 

Basic Information

Type General purpose counter Display method LCD Display Digits 6 digits
Count input (CH = N) 1 Mounting Method Panel / surface mount shared Panel cut dimensions 45x45
Power Supply Voltage AC-dedicated Output Relay Prescale Available
Representative Standard CE / UL / CSA Dimension vertical(mm) 48 Dimension width(mm) 48
Dimension depth(mm) 63.7 Classification Tacometer MAX input frequency (MAX counting speed) (Hz) 30Hz/10kHz
Power supply voltage details(V) AC 100–240 Output Specification Contact output (1c) Protective Structure IP66
Color Black

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)