Safety Relay, G7S (G7S-4A2B-E DC24)

Safety Relay, G7S G7S-4A2B-E DC24

[Features]
· Safety rail for safety light curtain F3SJ-E. G7S.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

G7S-4A2B-E DC24

Safety Relay G7S Series Specifications

ClassificationNumber Of PolesContact ConfigurationRated VoltageFormat
Standard Type6 poles4 a 2 b24 V DCModel G7S-4A2B-E
3 a 3 bModel G7S-3A3B-E
Safety Relay G7S: related images

G7S-4A2B-E/G7S-3A3B-E external appearance

Safety Relay G7S: related images

G7S-4A2B-E/G7S-3A3B-E dimensional drawings, Units: mm

Safety Relay G7S: related images

G7S-4A2B-E terminal layout / internal schematics

Safety Relay G7S: related images

G7S-3A3B-E terminal layout / internal schematics

Safety Relay G7S: related images

Mounting hole dimensions, Units: mm

Rating

Operating Coil

Rated VoltageRated Current (mA)Coil Resistance (Ω)Maximum Continuous Allowable Voltage (V)Power Consumption (W)
24 V DC30800110%Approx. 0.8
  • *The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
  • *The figures for the operating characteristics are for a coil temperature of +23°C.

Switch (Contact)

LoadResistive Load
Rated Loada-Contact250 V AC 10 A, 30 V DC 10 A
b Contact250 V AC 6 A, 30 V DC 6 A
Rated Carry Currenta-Contact10 A
b Contact6 A
Max. Contact Voltage Value250 V AC, 30 V DC
Max. Contact Current Valuea-Contact10 A
b Contact6 A
"m-h3--wysiwyg">Performance
Contact Resistance *1100 mΩ max.
Operating Time *250 ms max.
Recovery Time *250 ms max.
Operating Voltage80% max. relative to rated voltage
Release Voltage10% min. relative to rated voltage
Maximum Switching FrequencyMechanical18,000 operations/hr
Rated Load1,800 operations/hr
Insulation Resistance *3100 MΩ min.
Dielectric Strength *4 *5Between coil and contacts (between coil and pole 3 or coil and pole 4): 4,000 VAC, 50/60 Hz for 1 min
Between coil and contacts (other than the above): 2,500 VAC, 50/60 Hz for 1 min
Between different poles (between pole 1, 3, or 5 and pole 2, 4, or 6): 4,000 VAC, 50/60 Hz for 1 min
Between different poles (other than the above): 2,500 VAC, 50/60 Hz for 1 min
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min
VibrationDurability10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
ShockDurability1,000 m/s2
Malfunction100 m/s2
Durability *6Mechanical10,000,000 operations min. (switching frequency 18,000 operations/hr)
Electrical100,000 operations min. (at 1,800 operations/hr under rated load)
Inductive Load Switching Performance *7
(IEC60947-5-1)
a-ContactAC15 240 V AC 5 A
DC13 24 V DC 2 A
b ContactAC15 240 V AC 3 A
DC13 24 V DC 2 A
Failure Rate (P Level) (Reference Value *8)5 V DC 1 mA
Ambient Operating Temperature-25 to +70°C (assuming no icing or condensation)
Ambient Operating Humidity5 to 85% RH
WeightApprox. 65 g
  • The values given above are initial values.
  • *The figures for the operating characteristics are for a coil temperature of +23°C.

*1. Measurement conditions: 5 V DC, 10 mA, voltage drop method.
*2. Measurement conditions: rated voltage operation. Ambient temperature conditions: +23°C. Bounce time not included.
*3. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
*4. When using a P7S socket, the dielectric strength between coil contacts/different poles is 2,000 V AC, 50/60 Hz for 1 min.
*5. The coil refers to terminals 0-1, pole 1 refers to terminals 13−14, pole 2 refers to terminals 23−24, pole 3 refers to terminals 33−34, pole 4 refers to terminals 41−42 or 43−44, pole 5 refers to terminals 51−52, and pole 6 refers to terminals 61−62.
*6. The durability is for an ambient temperature of 15 to +35°C and an ambient humidity of 25% to 75% RH.
*7. AC15: cosφ = 0.3 mm, DC13: L/R = 96 ms inductive load.
*8. This value is based on a switching frequency of 60 operations/min.

  • *See the catalog for usage precautions, etc.
Part Number
G7S-4A2B-E DC24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipContact Configuration

MYR 120.00

1 Piece(s) 2 Day(s) [Other] 4a2b

Loading...

  1. 1
 

Basic Information

Application Safety relay Latch function NA Terminal shape Socket / plug-in
Contact rated current (minimum value for AC and DC)(A) 6 Coil rated voltage (DC)(V) 24 Representative Standard UL / CSA
Dimension height(mm) 37 Dimension width(mm) 22.5 Dimension depth(mm) 58
Classification Standard Type Note Dangerous situations in and around the machinery are avoided by the use of an interlock type circuit configuration.

Please check the type/dimensions/specifications of the part G7S-4A2B-E DC24 in the Safety Relay, G7S series.

Products like this...

Part Number
G7S-3A3B-E DC24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipContact Configuration

MYR 120.00

1 Piece(s) 5 Day(s) or more [Other] 3a3b