Chain Flex CF130.UL- Control Cable (CF130.02.03.UL-0.25SQ-3-46)

Chain Flex CF130.UL- Control Cable CF130.02.03.UL-0.25SQ-3-46

Features
● Supports standard loads
● PVC jacketing
● Flame retardant

Application
● For indoor use
● Particularly suited to free-span travel and sliding travel (50m max.)
● Ideal for woodworking machinery, stone processing machinery, packaging machinery, material handling equipment, automatic adjustment equipment.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

CF130.02.03.UL-0.25SQ-3-46

Configured Specifications

Overall Length(m)46Conductor Cross Section(mm2)0.25
Number Of Cores(Core)3Finished outer diameter(mm)5
Rated Voltage[300V] 300/300VShieldNA
Representative StandardUL / CE / CSA(c-UL)Sheath (outer coating) color[Gray] Gray
Grounding Wire[NA] NASheath (outer coating) material[PVC (Polyvinyl Chloride)] Low adhesiveness PVC admixture
Insulation body materials[Other] TPE admixtureMinimum bending radius while running (Stroke Length: less than 10 m)(mm)37.5
Show More
Minimum bend radius while running (stroke length: More than 10 m)(mm)50Minimum bending radius when fixed(mm)25
Free span maximum running speed(m/s)3Slide maximum running speed(m/s)2
Maximum acceleration(m/s2)20StrokeUp to 50m
Twist(° (1 m))±90Conductor resistance(Ω/km)79
Reference allowable current value (30°C)(A)5Other standardsISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2012: Used of UL (AWM) cable allowed
Other cable propertiesFlame retardant and silicone freeNote 1Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors
RoHS10 - -
Show Less
Part Number
CF130.02.03.UL-0.25SQ-3-46
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)

MYR 582.52

1 Piece(s) 6 Day(s) or more 10460.2535[300V] 300/300V[NA] NA37.55025795
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)
  1. 1

Basic Information

Shield NA Representative Standard UL / CE / CSA(c-UL) Sheath (outer coating) color Gray
Sheath (outer coating) material Low adhesiveness PVC admixture Insulation body materials TPE admixture Free span maximum running speed(m/s) 3
Slide maximum running speed(m/s) 2 Maximum acceleration(m/s2) 20 Stroke Up to 50m
Twist(° (1 m)) ±90 Other standards ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2012: Used of UL (AWM) cable allowed Other cable properties Flame retardant and silicone free
Note 1 Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

Please check the type/dimensions/specifications of the part CF130.02.03.UL-0.25SQ-3-46 in the Chain Flex CF130.UL- Control Cable series.

Products like this...

Part Number
CF130.02.03.UL-0.25SQ-3-11
CF130.02.03.UL-0.25SQ-3-12
CF130.02.03.UL-0.25SQ-3-13
CF130.02.03.UL-0.25SQ-3-47
CF130.02.03.UL-0.25SQ-3-48
CF130.02.03.UL-0.25SQ-3-49
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)

MYR 150.57

1 Piece(s) 6 Day(s) or more 10110.2535[300V] 300/300V[NA] NA37.55025795

MYR 162.91

1 Piece(s) 6 Day(s) or more 10120.2535[300V] 300/300V[NA] NA37.55025795

MYR 175.25

1 Piece(s) 6 Day(s) or more 10130.2535[300V] 300/300V[NA] NA37.55025795

MYR 594.85

1 Piece(s) 6 Day(s) or more 10470.2535[300V] 300/300V[NA] NA37.55025795

MYR 607.19

1 Piece(s) 6 Day(s) or more 10480.2535[300V] 300/300V[NA] NA37.55025795

MYR 619.54

1 Piece(s) 6 Day(s) or more 10490.2535[300V] 300/300V[NA] NA37.55025795
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)

Not a MISUMI customer yet? Register & enjoy 50% off your 1st order!* (*T&C apply.)

  • 7 Million Products
  • 2,000 Brands
  • Free CAD downloads
  • Quote/order any time