(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Detects network abnormalities
Instantly notifies with light, sound and email
Part Number
Configured Part Number is shown.
NHP-3FV2-RYG
Network Monitor Signal Tower with MP3 Catalog, NH□-□FV2□-□□□□□ Click here
Details of the network monitoring indicator lights NHS-FV1/NHP-FV1/NHL-FV1
Network monitoring indicator NHS-FV1 product image | Network monitoring indicator NHP-FV1 product image | Network monitoring indicator NHL-FV1 product image |
Network monitoring indicator NHS-FV1/NHP-FV1/NHL-FV1 specifications
NHS-FV1 Series
(Unit: mm) NHS-FV1 series dimensional diagram |
Number of steps | 1st tier | 2nd grade | 3 levels | 4 levels | 5 levels |
Body length (mm) | 198 | 228 | 258 | 288 | 318 |
Mass (g) | 940 | 950 | 960 | 970 | 980 |
Product Model | NHS-3FV1-RYG | |
---|---|---|
network | Physical Layer | Ethernet (IEEE802.3 compliant) 10BASE-T/100BASE-TX (auto-negotiation, full-duplex/half-duplex) |
Data Link Layer | CSMA/CD | |
Network Layer | IP, ICMP, ARP | |
Transport Layer | TCP/UDP | |
Application Layer | HTTP, SMTP, SNMP, RSH, NTP, POP, DNS, SOCKET, DHCP, SLMP | |
Other Features | Clear Switch | Yes (lights off and sound stopped) |
Self-diagnosis function | can be | |
Number of steps | 1 to 5 levels (can be changed after purchase) | |
Color sequence | Standard color (can be changed after purchase) | |
Configuration Features | Web Settings | |
Indicator Light Section | Emitting color | Red, yellow, green, blue, white (LED) |
Number of flashes (cycle) | 60 times/min | |
Sound pressure level (at1m/variable) | Maximum 88dB or more to 0 | |
Sound Type | Voice/Buzzer | |
Audio Line Output | can be | |
Number of playback sounds | Up to 70 types | |
Buzzer sound | 4 sounds (beep beep beep beep beep) (beep beep beep) (beep beep beep) (beep *continuous sound) | |
Playback Mode | Last input priority playback/Memory playback | |
Volume adjustment | Stepless adjustment by analog vol. / Input from web screen | |
BUSY output | can be | |
Specifications | power consumption | Main unit 2.2W |
3.5W | ||
Power supply | Dedicated AC adapter included (compliant with Japanese regulations) | |
Rated voltage | Main unit: DC24V / AC adapter: AC100V-240V | |
Operating temperature limit | 0 to 40°C | |
Operating humidity range | 20 to 80% RH or less (no condensation) | |
External Contact Output | 1point | |
External Contact Input | 4 points | |
USB port | TYPE-A 1 item | |
Operation section | Clear switch, reset switch, test switch, mode switch, volume | |
Compliance standards | CE marking compliance: EN55032, EN55024 |
NHP-FV1 series/NHL-FV1 series
(Unit: mm) NHP-FV1 series/NHL-FV1 series dimensional diagram |
Body length and weight of NHP-□FV1 type by number of stages
Number of steps | 1st tier | 2nd grade | 3 levels | 4 levels | 5 levels |
Body length (mm) | 276 | 311 | 346 | 381 | 416 |
Mass (g) | 980 | 1,010 | 1,040 | 1,070 | 1,100 |
NHL-□FV1 type body length by number of stages
Number of steps | 1st tier | 2nd grade | 3 levels | 4 levels | 5 levels |
Body length (mm) | 268 | 309 | 350 | 391 | 432 |
Mass (g) | 1,050 | 1,100 | 1,150 | 1,200 | 1,250 |
*Weight does not include AC adapter.
Product Model | NHP-□FV1-□□□ | NHL-□FV1-□□□ | |
---|---|---|---|
network | Physical Layer | Ethernet (IEEE802.3 compliant) 10BASE-T/100BASE-TX (auto-negotiation, full-duplex/half-duplex) | |
Data Link Layer | CSMA/CD | ||
Network Layer | IP, ICMP, ARP | ||
Transport Layer | TCP/UDP | ||
Application Layer | HTTP, SMTP, SNMP, RSH, NTP, POP, DNS, SOCKET, DHCP, SLMP | ||
Other Features | Clear Switch | Yes (lights off and sound stopped) | |
Self-diagnosis function | can be | ||
Number of steps | 1 to 5 levels (can be changed after purchase) | ||
Color sequence | Standard color (can be changed after purchase) | ||
Configuration Features | Web Settings | ||
Indicator Light Section | Emitting color | Red, yellow, green, blue, white (LED) | |
Number of flashes (cycle) | 60 times/min | ||
Sound pressure level (at1m/variable) | Maximum 88dB or more to 0 | ||
Sound Type | Voice/Buzzer | ||
Audio Line Output | can be | ||
Number of playback sounds | Up to 70 types | ||
Buzzer sound | 4 sounds (beep beep beep beep beep) (beep beep beep) (beep beep beep) (beep *continuous sound) | ||
Playback Mode | Last input priority playback/Memory playback | ||
Volume adjustment | Stepless adjustment by analog vol. / Input from web screen | ||
BUSY output | can be | ||
Specifications | power consumption | Main unit 2.2W | |
3.5W | |||
Power supply | Dedicated AC adapter included (compliant with Japanese regulations) | ||
Rated voltage | Main unit: DC24V / AC adapter: AC100V-240V | ||
Operating temperature limit | 0 to 40°C | ||
Operating humidity range | 20 to 80% RH or less (no condensation) | ||
External Contact Output | 1point | ||
External Contact Input | 4 points | ||
USB port | TYPE-A 1 item | ||
Operation section | Clear switch, reset switch, test switch, mode switch, volume | ||
Compliance standards | FCC Part 15 Subpart B Class A |
Part Number |
---|
NHP-3FV2-RYG |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS |
---|---|---|---|---|---|
MYR 6,292.30 | 1 Piece(s) | 5 Day(s) or more | 10 |
Loading...
Type | Standard | Shape | Round | Thickness | Ø40 |
---|---|---|---|---|---|
Rated Voltage(V) | DC24V | Number of Steps | 3 | Color (top stage) | Red |
Color (second stage) | Yellow | Color (third stage) | Green | Light Source | LED |
Mounting Method | Floor Mounting | Buzzer (with/without) | Available | Lighting/blinking | Lighting/blinking |
Representative Standard | PSE / CE / UL / CSA | Body length | 336 | Self-diagnostic function | Yes |
JAN code | 4938766021266 | Note | PSE: for included AC adapter only |
Please check the type/dimensions/specifications of the part NHP-3FV2-RYG in the MP3 Network Monitor Signal Tower series.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy