Molded Case Circuit Breakers (MCCB) NF-SVF Series with accessories (NF32-SVF 2P 10A AX SLT)

Part Number

Configured Part Number is shown.

NF32-SVF 2P 10A AX SLT

Configured Specifications

Ampere frame32AFRated block capacity AC 200 V(kA)7.5
Rated block capacity AC 400 V(kA)5Rated block capacity, voltages except VAC 100/200/400, VDC 250Available
Number of Poles2Rated Current(A)10
Mounting MethodDIN rail mountConnection MethodSurface type
Representative StandardPSE / CE / CCCDimension height(mm)100
Dimension width(mm)36Dimension depth(mm)90
Show More
TypeNo-fuse breakerFormat-
Rated block capacity AC 415 V(kA)5Rated block capacity DC 125 V(kA)10
Rated breaking capacity (kA)2.5(AC440V), 5(AC380V)Internal included equipment Auxiliary switch / Vertical lead wire terminal block
Show Less

MITSUBISHI Circuit Breakers Specifications

Circuit Breakers Part NumberCircuit Breakers Model NF32-SVFCircuit Breakers Model NF63-SVF
Rated Current In
Standard Ambient Temperature 40°C A
3 5 10
15 20 30
32(3) (5) (10)
15 20 30
40 50
60(63)
Number of Positions2323232323
Rated Insulation Voltage Ui V440440440440440
Rated Short-Circuit Breaking Capacity
kA
JIS C 8201-2-1 
Ann.1
JIS C 8201-2-1
Ann.2
IEC 60947-2
EN 60947-2
(Icu/Ics)
AC690 V-----
500 V-----
440 V2.5/2.52.5/2.57.5/67.5/67.5/6
415 V5/55/510/810/810/8
400 V5/55/510/810/810/8
380 V5/55/510/810/810/8
230 V7.5/7.57.5/7.515/1515/1515/15
DC
(*1)
250 V-----
125 V10/1010/1010/1010/1010/10
GB 14048.2
(lcu/lcs)
AC415 V5/55/510/810/810/8
400 V5/55/510/810/810/8
380 V5/55/510/810/810/8
230 V7.5/7.57.5/7.515/1515/1515/15
DC
(*1)
250 V-----
125 V10/1010/1010/1010/1010/10
Standard Included Parts (Surface Type)IEC 35-mm Circuit Breakers Rail Mounting Clip
(*2) Insulation Barriers (2 Positions 2 Plates, 3 Positions 4 Plates)

*(1) For 3-position Circuit Breakers, use 2 positions.
(2) Only compatible with NF63-SVF 60A and 63A.
 Note (1) Mounting screws must be prepared by the customer (recommended size: M4 × 0.7 × 65 [2 pieces])

 
Circuit Breakers Part NumberCircuit Breakers Model NF125-SVF
Rated Current In
Standard Ambient Temperature for Circuit Breakers 40°C A
15 20 30 40 50
60 75 100
125
Number of Positions2323
Rated Insulation Voltage Ui V600600
Rated Short-Circuit Breaking Capacity
kA
JIS C 8201-2-1 
Ann.1
JIS C 8201-2-1
Ann.2
IEC 60947-2
EN 60947-2
(Icu/Ics)
AC690 V--
500 V10/1010/10
440 V20/2020/20
415 V25/2525/25
400 V25/2525/25
380 V25/2525/25
230 V50/5050/50
DC
(*1)
250 V--
125 V15/1515/15
GB 14048.2
(lcu/lcs)
AC415 V25/2525/25
400 V25/2525/25
380 V25/2525/25
230 V50/5050/50
DC
(*1)
250 V--
125 V15/1515/15
Standard Included Parts (Surface Type)IEC 35-mm Circuit Breakers Rail Mounting Clip
Insulation Barriers (2 Positions 1 Piece, 3 Positions 2 Pieces)
M4 × 0.7 × 55 Mounting Screws (2 Pieces)

*(1) For 3-position Circuit Breakers, use 2 positions.

Drawing Showing Dimensions of MITSUBISHI Circuit Breakers

Drawing 01 of WS-V Series MCCB F Style NF-S Class (General Products)

Circuit Breakers Model NF32-SVF・NF63-SVF
Surface Type
Note (1) Direct cable connection is not possible.
(2) Motor breakers only have 3 positions.

 
Drawing 02 of WS-V Series MCCB F Style NF-S Class (General Products)

Circuit Breakers Model NF125-SVF
Surface Type
Note (1) The 2-position product of NF125-SVF is the product where the middle pole of the 3-pole breaker is removed.

Part Number
NF32-SVF 2P 10A AX SLT
Part NumberMinimum order quantityVolume DiscountDays to ShipAmpere frame Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current
(A)
Mounting Method Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Type Format Rated block capacity AC 415 V
(kA)
Rated block capacity DC 125 V
(kA)
Rated breaking capacity 
(kA)
Internal included equipment
1 Piece(s) Quote 32AF7.55Available210DIN rail mountPSE / CE / CCC1003690No-fuse breaker-5102.5(AC440V), 5(AC380V) Auxiliary switch / Vertical lead wire terminal block
Part Number
Part NumberMinimum order quantityVolume DiscountDays to ShipAmpere frame Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current
(A)
Mounting Method Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Type Format Rated block capacity AC 415 V
(kA)
Rated block capacity DC 125 V
(kA)
Rated breaking capacity 
(kA)
Internal included equipment
  1. 1

Basic Information

Connection Method Surface type

Please check the type/dimensions/specifications of the part NF32-SVF 2P 10A AX SLT in the Molded Case Circuit Breakers (MCCB) NF-SVF Series with accessories series.

Products like this...

Part Number
NF125-SVF 3P 40A
NF125-SVF 3P 50A
NF32-SVF 2P 10A
NF32-SVF 2P 15A
NF32-SVF 2P 20A
NF32-SVF 2P 30A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAmpere frame Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current
(A)
Mounting Method Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Type Format Rated block capacity AC 415 V
(kA)
Rated block capacity DC 125 V
(kA)
Rated breaking capacity 
(kA)
Internal included equipment

-

1 Piece(s) Quote [100AF to 199AF] 100AF5025-340DIN/Screw retentionCE / TUV / PSE / CCC1307568-General-Purpose Product----

-

1 Piece(s) Quote [100AF to 199AF] 100AF5025-350DIN/Screw retentionCE / TUV / PSE / CCC1307568-General-Purpose Product----

MYR 190.05

1 Piece(s) Quote 30AF7.55-210DIN/Screw retentionCE / TUV / PSE / CCC1003690-General-Purpose Product----

-

1 Piece(s) Quote 30AF7.55-215DIN/Screw retentionCE / TUV / PSE / CCC1003690-General-Purpose Product----

-

1 Piece(s) Quote 30AF7.55-220DIN/Screw retentionCE / TUV / PSE / CCC1003690-General-Purpose Product----

MYR 213.64

1 Piece(s) 23 Day(s) 30AF7.55-230DIN/Screw retentionCE / TUV / PSE / CCC1003690-General-Purpose Product----
Part Number
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAmpere frame Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current
(A)
Mounting Method Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Type Format Rated block capacity AC 415 V
(kA)
Rated block capacity DC 125 V
(kA)
Rated breaking capacity 
(kA)
Internal included equipment

Additional Products in this Category

Tech Support

Not a MISUMI customer yet? Register & enjoy 50% off your 1st order!* (*T&C apply.)

  • 7 Million Products
  • 2,000 Brands
  • Free CAD downloads
  • Quote/order any time