Pictest (without Stem, V Series)

Pictest (without Stem, V Series)

Miniature bearings are used for the bearings of the fulcrum portion of the gauge heads to reduce the effects of rod play and achieve excellent indicating stability.

PDF

Part Number

Configured Part Number is shown.

 
Part Number
PC-1AV
PC-1BV
PC-1LV
PC-2V
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipScale Interval / Minimum Display
(mm)
Measuring Range
(mm)
Scale Specification [Accuracy (µm)] Wide range bound accuracy [Accuracy (µm)] Adjacent Error
(µm)
[Accuracy (µm)] Return Error
(µm)
Specifications

MYR 480.20

1 Piece(s) 6 Day(s) or more 0.010.50-25-0553No stem, switching lever type

MYR 480.20

1 Piece(s) 6 Day(s) or more 0.010.80-40-0853No stem, switching lever type

MYR 588.09

1 Piece(s) 6 Day(s) or more 0.0110-50-01054No stem, switching lever type, with long measurement probe (XP1L-2)

MYR 588.09

1 Piece(s) 6 Day(s) or more 0.0020.280-140-0322No stem, switching lever type, high accuracy

Loading...

  1. 1

Basic Information

Use Lever Type (Indicator) Display Method Dial Maximum Measuring Length (Adjustment Range)(mm) 0 ~ 1
Scale type Balance scale Waterproof Function Included Measuring Force (or Less)(N) 0.4
Features Since miniature bearings are used for the bearings of the fulcrum portion of the measuring probe, shaft play impact is small and the presentation stability is superior. O-rings have been incorporated to prevent water and oil from coming in through gaps between the outer frame and inner frame, providing superior waterproofness. Gauge breakage prevention probes are attached to all instrument types. Adoption of balancing needles keeps errors due to posture differences (gauge mounting direction) as small as possible.