(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (MYT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Control/Instrumentation Cables(Logarithm:18P)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 2 Day(s) or Less
  • 3 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 57 Day(s) or Less
  • 71 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    Shielded Twisted Pair Multi-Core Cable, SPMC Series

      BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

        UL Listed Unshielded Instrumentation Cable

          Twisted Pair Instrumentation Cable

            NA3VCSB UL Standard with Shield

              BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                Twisted Pair Multi-Core Cable PMC Series

                  NAKVVSB 100 V or less with Shield

                    Thick Multi-Pair Cable

                      HP-SB/20276SR LF

                        NA20276HB Cross-Linked Polyethylene UL with Shield

                          NA3VC UL Standard

                          Brand

                          KANEKO CORD

                          BANDO DENSEN

                          TACHII ELECTRIC WIRE

                          TACHII ELECTRIC WIRE

                          MISUMI

                          BANDO DENSEN

                          KANEKO CORD

                          MISUMI

                          HITACHI CABLE

                          TAIYO CABLETEC

                          MISUMI

                          MISUMI

                          Product Series

                          Shielded Twisted Pair Multi-Core Cable, SPMC Series

                          BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                          UL Listed Unshielded Instrumentation Cable

                          Twisted Pair Instrumentation Cable

                          NA3VCSB UL Standard with Shield

                          BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                          Twisted Pair Multi-Core Cable PMC Series

                          NAKVVSB 100 V or less with Shield

                          Thick Multi-Pair Cable

                          HP-SB/20276SR LF

                          NA20276HB Cross-Linked Polyethylene UL with Shield

                          NA3VC UL Standard

                          Days to Ship 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 6 Day(s) or more 4 Day(s) or more 4 Day(s) or more
                          Specifications
                                  • VW-1
                                  • ULAWM
                                  • Oil-Resistant
                                  • Strand Wire
                                  • Single Shield
                                  • Twisted Pair
                                  • 300 V
                                      • Oil-Resistant
                                      • Strand Wire
                                      • Single Shield
                                      • Twisted Pair
                                      • Less than 100 V
                                          • VW-1
                                          • ULAWM
                                          • Oil-Resistant
                                          • Strand Wire
                                          • Single Shield
                                          • Twisted Pair
                                          • 30 V
                                          • VW-1
                                          • ULAWM
                                          • Oil-Resistant
                                          • Strand Wire
                                          • Twisted Pair
                                          • 300 V
                                          Overall Length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001001001 ~ 100
                                          Specified Length(m)------------
                                          Conductor Cross Section(mm2)0.15-0.22 ~ 0.340.2 ~ 0.30.2 ~ 0.3-0.150.2 ~ 0.30.20.08040.120.2 ~ 0.3
                                          AWG size(AWG)2624 ~ 2622 ~ 2422 ~ 2423 ~ 25262623 ~ 2524282623 ~ 25
                                          Number Of Cores(Core)36-3636--36-3636--
                                          Logarithm18P18P18P18P18P18P18P18P18P18P18P18P
                                          Finished outer diameter(mm)-11.2 ~ 12.412.4 ~ 14.211 ~ 13.410.8 ~ 12.610.4-11 ~ 13.4-7.210.110.3 ~ 11.9
                                          Rated VoltageFor High Voltages300V300VOther300V300VFor Low Current CircuitsFor Low Current Circuits300VFor Low Current CircuitsFor Low Current Circuits300V
                                          ShieldAvailableAvailableNAAvailableAvailableNANAAvailableAvailableAvailableAvailableNA
                                          Properties-Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil ResistanceHeat-Resistance-Oil ResistanceHeat-ResistanceOil Resistance / Heat-ResistanceOil ResistanceOil Resistance
                                          Representative Standard-UL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)ULUL / CSA(c-UL)--ULULULUL
                                          Sheath (outer coating) colorBlackBlackBlackGrayBlueBlackBlackBlueGrayBlackBlueBlue
                                          Grounding WireNA-NAOther--NA--NA--
                                          Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                                          Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Polyethylene-BasedPVC (Polyvinyl Chloride)

                                          Loading...

                                          1. 1

                                          Related Categories to Control/Instrumentation Cables