(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information. 
  • Please note that E-Invoice will be sent to our customers by email. For more information, please read News. 

Control/Instrumentation Cables(Representative Standard:CSA(c-UL))

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 2 Day(s) or Less
  • 3 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 57 Day(s) or Less
  • 71 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

      Twisted Pair Instrumentation Cable

        UL Listed Unshielded Instrumentation Cable

          KVC-36SBT

            BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

              Twisted Layer Instrumentation Cable

                KVC36 UL Standard

                  CL2/2464-3599-DS LF

                    HK/20276 XL LF

                    Brand

                    BANDO DENSEN

                    TACHII ELECTRIC WIRE

                    TACHII ELECTRIC WIRE

                    KURAMO ELECTRIC

                    BANDO DENSEN

                    TACHII ELECTRIC WIRE

                    MISUMI

                    TAIYO CABLETEC

                    TAIYO CABLETEC

                    Product Series

                    BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                    Twisted Pair Instrumentation Cable

                    UL Listed Unshielded Instrumentation Cable

                    KVC-36SBT

                    BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                    Twisted Layer Instrumentation Cable

                    KVC36 UL Standard

                    CL2/2464-3599-DS LF

                    HK/20276 XL LF

                    Days to Ship 4 Day(s) or more 4 Day(s) or more 2 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 2 Day(s) 4 Day(s) or more 2 Day(s) or more
                    Specifications
                                • c-UL
                                • VW-1
                                • FT-1
                                • ULAWM
                                • Oil-Resistant
                                • Strand Wire
                                • Twisted Pair
                                • Less than 100 V
                                    Overall Length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001001 ~ 1005
                                    Specified Length(m)---------
                                    Conductor Cross Section(mm2)-0.2 ~ 0.50.22 ~ 0.540.5-0.2 ~ 0.30.20.204 ~ 0.8230.204
                                    AWG size(AWG)16 ~ 2620 ~ 2420 ~ 242016 ~ 2622 ~ 242518 ~ 2424
                                    Number Of Cores(Core)2 ~ 102 ~ 502 ~ 502 ~ 402 ~ 102 ~ 40---
                                    Logarithm1P ~ 25P1P ~ 25P1P ~ 25P1P ~ 20P1P ~ 20P-1P ~ 2P1P ~ 5P2P
                                    Finished outer diameter(mm)4.7 ~ 18.34.6 ~ 15.94 ~ 154.8 ~ 164.1 ~ 17.64.6 ~ 11.63.1 ~ 5.25.1 ~ 145.2
                                    Rated Voltage300VOther300VFor Low Current Circuits300VOtherFor Low Current CircuitsFor Low Current CircuitsFor Low Current Circuits
                                    ShieldAvailableAvailableNAAvailableNAAvailableNAAvailableNA
                                    PropertiesOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-Resistance
                                    Representative StandardCSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)
                                    Sheath (outer coating) colorBlackGrayBlackBlackBlackBlackBlackBlackBlack
                                    Grounding Wire-OtherNAOther-Other-NANA
                                    Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Other
                                    Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Polyethylene-BasedOther

                                    Loading...

                                    1. 1

                                    Related Categories to Control/Instrumentation Cables